Kunal Vyas
Research Subjects
Kunal Vyas has a total of 142 co-authors. Here are the top co-authors by number of shared publications:
David Tuch
Lightpoint Medical Ltd Chesham UK
5 shared publications- Justin Llandro
Laboratory for Nanoelectronics and Spintronics, Research Institute of Electrical Communication, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577, Japan
5 shared publications Thanos Mitrelias
Cavendish Laboratory, Department of Physics, University of Cambridge, Cambridge CB3 0HE, UK
4 shared publications- Thanos Mitrelias
Cavendish Laboratory, Department of Physics, University of Cambridge, JJ Thomson Avenue, CB3-0HE Cambridge, UK
4 shared publications Amit Pawa
Anesthetic Department, Guy’s and St Thomas’ NHS Foundation Trust, London, United Kingdom
3 shared publications- Arnie Purushotham
School of Cancer and Pharmaceutical Sciences, King’s College London, London, United Kingdom
3 shared publications
Latest Publications
- Open Access
Self-Supervised Depth Estimation in Laparoscopic Image using 3D Geometric Consistency
Depth estimation is a crucial step for image-guided intervention in robotic surgery and laparoscopic imaging system. Since per-pixel depth ground truth is difficult to acquire for laparoscopic image data, it is rarely possible to apply supervised depth estimation to surgical applications. As an alternative, self-supervised methods have been introduced to train depth estimators using only synchronized stereo image pairs. However, most recent work focused on the left-right consistency in 2D and ignored valuable inherent 3D information on the object in real world coordinates, meaning that the left-right 3D geometric structural consistency is not fully utilized. To overcome this limitation, we present M3Depth, a self-supervised depth estimator to leverage 3D geometric structural information hidden in stereo pairs while keeping monocular inference. The method also removes the influence of border regions unseen in at least one of the stereo images via masking, to enhance the correspondences between left and right images in overlapping areas. Intensive experiments show that our method outperforms previous self-supervised approaches on both a public dataset and a newly acquired dataset by a large margin, indicating a good generalization across different samples and laparoscopes. Code and data are available at https://github.com/br0202/M3Depth.
Open AccessSelf-Supervised Depth Estimation in Laparoscopic Image using 3D Geometric Consistency
Depth estimation is a crucial step for image-guided intervention in robotic surgery and laparoscopic imaging system. Since per-pixel depth ground truth is difficult to acquire for laparoscopic image data, it is rarely possible to apply supervised depth estimation to surgical applications. As an alternative, self-supervised methods have been introduced to train depth estimators using only synchronized stereo image pairs. However, most recent work focused on the left-right consistency in 2D and ignored valuable inherent 3D information on the object in real world coordinates, meaning that the left-right 3D geometric structural consistency is not fully utilized. To overcome this limitation, we present M3Depth, a self-supervised depth estimator to leverage 3D geometric structural information hidden in stereo pairs while keeping monocular inference. The method also removes the influence of border regions unseen in at least one of the stereo images via masking, to enhance the correspondences between left and right images in overlapping areas. Intensive experiments show that our method outperforms previous self-supervised approaches on both a public dataset and a newly acquired dataset by a large margin, indicating a good generalization across different samples and laparoscopes. Code and data are available at https://github.com/br0202/M3Depth.
- 27 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 7 (2) , 143-150
Real-Time Deep-Learned Reconstruction for a Scanning Intraoperative Probe
Accurate delineation of the boundary between cancerous and healthy tissue during cancer resection surgeries is important to ensure complete removal of cancerous cells while preserving healthy tissue. Labelling cancer cells with radiotracers, and then using a probe during surgery to detect the radiotracer distribution, is a potential solution for accurate tumour localisation and hence better surgical outcomes. This work explores the feasibility of using deep learning to reconstruct a radiotracer distribution from data acquired by an intraoperative probe. The probe’s sensor array outputs (SAOs), obtained by scanning the probe over a region of interest, are supplied to the deep network, which then outputs a reconstructed radiotracer distribution for the region of interest. This initial work demonstrates that the deep network used here, a convolutional encoder decoder (CED), can successfully reconstruct simulated 2D radiotracer distributions from synthesised input data. However, the network was unable to generalise reliably when tested with count levels not present in the training set. Therefore the network must be trained with desired count levels or else should include estimation of epistemic uncertainty to avoid misleading outcomes. We also show that test-time augmentation can improve reconstructed image quality, and hence can also be used to reduce the amount of training data required.
- 27 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 7 (2) , 143-150
Real-Time Deep-Learned Reconstruction for a Scanning Intraoperative Probe
Accurate delineation of the boundary between cancerous and healthy tissue during cancer resection surgeries is important to ensure complete removal of cancerous cells while preserving healthy tissue. Labelling cancer cells with radiotracers, and then using a probe during surgery to detect the radiotracer distribution, is a potential solution for accurate tumour localisation and hence better surgical outcomes. This work explores the feasibility of using deep learning to reconstruct a radiotracer distribution from data acquired by an intraoperative probe. The probe’s sensor array outputs (SAOs), obtained by scanning the probe over a region of interest, are supplied to the deep network, which then outputs a reconstructed radiotracer distribution for the region of interest. This initial work demonstrates that the deep network used here, a convolutional encoder decoder (CED), can successfully reconstruct simulated 2D radiotracer distributions from synthesised input data. However, the network was unable to generalise reliably when tested with count levels not present in the training set. Therefore the network must be trained with desired count levels or else should include estimation of epistemic uncertainty to avoid misleading outcomes. We also show that test-time augmentation can improve reconstructed image quality, and hence can also be used to reduce the amount of training data required.
- 25 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (2) , 335-338
Simultaneous Depth Estimation and Surgical Tool Segmentation in Laparoscopic Images
Surgical instrument segmentation and depth estimation are crucial steps to improve autonomy in robotic surgery. Most recent works treat these problems separately, making the deployment challenging. In this paper, we propose a unified framework for depth estimation and surgical tool segmentation in laparoscopic images. The network has an encoder-decoder architecture and comprises two branches for simultaneously performing depth estimation and segmentation. To train the network end to end, we propose a new multi-task loss function that effectively learns to estimate depth in an unsupervised manner, while requiring only semi-ground truth for surgical tool segmentation. We conducted extensive experiments on different datasets to validate these findings. The results showed that the end-to-end network successfully improved the state-of-the-art for both tasks while reducing the complexity during their deployment.
- 25 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (2) , 335-338
Simultaneous Depth Estimation and Surgical Tool Segmentation in Laparoscopic Images
Surgical instrument segmentation and depth estimation are crucial steps to improve autonomy in robotic surgery. Most recent works treat these problems separately, making the deployment challenging. In this paper, we propose a unified framework for depth estimation and surgical tool segmentation in laparoscopic images. The network has an encoder-decoder architecture and comprises two branches for simultaneously performing depth estimation and segmentation. To train the network end to end, we propose a new multi-task loss function that effectively learns to estimate depth in an unsupervised manner, while requiring only semi-ground truth for surgical tool segmentation. We conducted extensive experiments on different datasets to validate these findings. The results showed that the end-to-end network successfully improved the state-of-the-art for both tasks while reducing the complexity during their deployment.
- 11 April 2022
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 6 (5) , 559-568
Prospective testing of clinical Cerenkov luminescence imaging against standard-of-care nuclear imaging for tumour location
In oncology, the feasibility of Cerenkov luminescence imaging (CLI) has been assessed by imaging superficial lymph nodes in a few patients undergoing diagnostic 18F-fluoro-2-deoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT). However, the weak luminescence signal requires the removal of ambient light. Here we report the development of a clinical CLI fiberscope with a lightproof enclosure, and the clinical testing of the setup using five different radiotracers. In an observational prospective trial (ClinicalTrials.gov identifier NCT03484884) involving 96 patients with existing or suspected tumours, scheduled for routine clinical FDG PET or 131I therapy, the level of agreement of CLI with standard-of-care imaging (PET or planar single-photon emission CT) for tumour location was ‘acceptable’ or higher (≥3 in the 1–5 Likert scale) for 90% of the patients. CLI correlated with the concentration of radioactive activity, and captured therapeutically relevant information from patients undergoing targeted radiotherapy or receiving the alpha emitter 223Ra, which cannot be feasibly imaged clinically. CLI could supplement radiological scans, especially when scanner capacity is limited.
- 11 April 2022
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 6 (5) , 559-568
Prospective testing of clinical Cerenkov luminescence imaging against standard-of-care nuclear imaging for tumour location
In oncology, the feasibility of Cerenkov luminescence imaging (CLI) has been assessed by imaging superficial lymph nodes in a few patients undergoing diagnostic 18F-fluoro-2-deoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT). However, the weak luminescence signal requires the removal of ambient light. Here we report the development of a clinical CLI fiberscope with a lightproof enclosure, and the clinical testing of the setup using five different radiotracers. In an observational prospective trial (ClinicalTrials.gov identifier NCT03484884) involving 96 patients with existing or suspected tumours, scheduled for routine clinical FDG PET or 131I therapy, the level of agreement of CLI with standard-of-care imaging (PET or planar single-photon emission CT) for tumour location was ‘acceptable’ or higher (≥3 in the 1–5 Likert scale) for 90% of the patients. CLI correlated with the concentration of radioactive activity, and captured therapeutically relevant information from patients undergoing targeted radiotherapy or receiving the alpha emitter 223Ra, which cannot be feasibly imaged clinically. CLI could supplement radiological scans, especially when scanner capacity is limited.
- Open Access
- 19 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 6 (4) , 446-453
Deep Learning Signal Discrimination for Improved Sensitivity at High Specificity for CMOS Intraoperative Probes
The challenge in delineating the boundary between cancerous and healthy tissue during cancer resection surgeries can be addressed with the use of intraoperative probes to detect cancer cells labeled with radiotracers to facilitate excision. In this study, deep learning algorithms for background gamma ray signal rejection were explored for an intraoperative probe utilizing CMOS monolithic active pixel sensors optimized toward the detection of internal conversion electrons from $^{99m}$ Tc. Two methods utilizing convolutional neural networks (CNNs) were explored for beta-gamma discrimination: 1) classification of event clusters isolated from the sensor array outputs (SAOs) from the probe and 2) semantic segmentation of event clusters within an acquisition frame of an SAO which provides spatial information on the classification. The feasibility of the methods in this study was explored with several radionuclides including 14 C, 57 Co, and $^{99m}$ Tc. Overall, the classification deep network is able to achieve an improved area under the curve (AUC) of the receiver operating characteristic (ROC), giving 0.93 for 14 C beta and $^{99m}$ Tc gamma clusters, compared to 0.88 for a more conventional feature-based discriminator. Further optimization of the lower left region of the ROC by using a customized AUC loss function during training led to an improvement of 31% in sensitivity at low false positive rates compared to the conventional method. The segmentation deep network is able to achieve a mean dice score of 0.93. Through the direct comparison of all methods, the classification method was found to have a better performance in terms of the AUC.
- 19 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 6 (4) , 446-453
Open AccessDeep Learning Signal Discrimination for Improved Sensitivity at High Specificity for CMOS Intraoperative Probes
The challenge in delineating the boundary between cancerous and healthy tissue during cancer resection surgeries can be addressed with the use of intraoperative probes to detect cancer cells labeled with radiotracers to facilitate excision. In this study, deep learning algorithms for background gamma ray signal rejection were explored for an intraoperative probe utilizing CMOS monolithic active pixel sensors optimized toward the detection of internal conversion electrons from $^{99m}$ Tc. Two methods utilizing convolutional neural networks (CNNs) were explored for beta-gamma discrimination: 1) classification of event clusters isolated from the sensor array outputs (SAOs) from the probe and 2) semantic segmentation of event clusters within an acquisition frame of an SAO which provides spatial information on the classification. The feasibility of the methods in this study was explored with several radionuclides including 14 C, 57 Co, and $^{99m}$ Tc. Overall, the classification deep network is able to achieve an improved area under the curve (AUC) of the receiver operating characteristic (ROC), giving 0.93 for 14 C beta and $^{99m}$ Tc gamma clusters, compared to 0.88 for a more conventional feature-based discriminator. Further optimization of the lower left region of the ROC by using a customized AUC loss function during training led to an improvement of 31% in sensitivity at low false positive rates compared to the conventional method. The segmentation deep network is able to achieve a mean dice score of 0.93. Through the direct comparison of all methods, the classification method was found to have a better performance in terms of the AUC.
- 30 April 2021
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 63 (1) , 29-35
Cerenkov Luminescence Imaging in Prostate Cancer: Not the Only Light That Shines
Introduction: Cerenkov luminescence imaging (CLI) is a novel imaging technology that might have the ability to assess surgical margins intra-operatively during prostatectomy using Gallium-68 prostate-specific membrane antigen ([68Ga]Ga-PSMA-11). This study evaluates the accuracy of CLI compared to histopathology and as exploratory objective investigates the characteristics of the identified chemiluminescence signal. Materials and Methods: After intravenous injection of a mean 68Ga-PSMA-11 activity of 69MBq intraoperatively, all excised specimens were imaged with CLI. Areas of increased signal were marked for histopathological comparison and scored for likelihood of being a positive surgical margin (PSM) using a 5-point Likert scale. In addition, the chemiluminescence signal was investigated in three radioactive and three non-radioactive specimens using CLI. Results: In 15 patients, the agreement between CLI and histopathology was 60%; this improved to 83% when including close surgical margins (≤1mm). In six hotspots, CLI correctly identified PSMs on histopathology, located at the apex and mid-prostate. In all 15 patients an increased signal at the prostate base was observed, without the presence of the primary tumor in this area in eight patients. This chemiluminescence signal was also observed in non-radioactive prostate specimens, with a half-life of 48±11min. The chemiluminescence hampered the visual interpretation of four PSMs at the base. Conclusion: CLI is able to correctly identify margin status, including close margins, in 83% of the cases. The presence of a diathermy-induced chemiluminescent signal hampered image interpretation, especially at the base of the prostate. In the current form, CLI is most applicable to detect PSMs and close margins in the apex and mid-prostate.
- 30 April 2021
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 63 (1) , 29-35
Cerenkov Luminescence Imaging in Prostate Cancer: Not the Only Light That Shines
Introduction: Cerenkov luminescence imaging (CLI) is a novel imaging technology that might have the ability to assess surgical margins intra-operatively during prostatectomy using Gallium-68 prostate-specific membrane antigen ([68Ga]Ga-PSMA-11). This study evaluates the accuracy of CLI compared to histopathology and as exploratory objective investigates the characteristics of the identified chemiluminescence signal. Materials and Methods: After intravenous injection of a mean 68Ga-PSMA-11 activity of 69MBq intraoperatively, all excised specimens were imaged with CLI. Areas of increased signal were marked for histopathological comparison and scored for likelihood of being a positive surgical margin (PSM) using a 5-point Likert scale. In addition, the chemiluminescence signal was investigated in three radioactive and three non-radioactive specimens using CLI. Results: In 15 patients, the agreement between CLI and histopathology was 60%; this improved to 83% when including close surgical margins (≤1mm). In six hotspots, CLI correctly identified PSMs on histopathology, located at the apex and mid-prostate. In all 15 patients an increased signal at the prostate base was observed, without the presence of the primary tumor in this area in eight patients. This chemiluminescence signal was also observed in non-radioactive prostate specimens, with a half-life of 48±11min. The chemiluminescence hampered the visual interpretation of four PSMs at the base. Conclusion: CLI is able to correctly identify margin status, including close margins, in 83% of the cases. The presence of a diathermy-induced chemiluminescent signal hampered image interpretation, especially at the base of the prostate. In the current form, CLI is most applicable to detect PSMs and close margins in the apex and mid-prostate.
- Open Access
- 18 March 2021
- Published by Springer Nature in EJNMMI Research
- Vol. 11 (1) , 1-12
Intraoperative [18F]FDG flexible autoradiography for tumour margin assessment in breast-conserving surgery: a first-in-human multicentre feasibility study
Introduction: In women undergoing breast-conserving surgery (BCS), 20–25% require a re-operation as a result of incomplete tumour resection. An intra-operative technique to assess tumour margins accurately would be a major advantage. A novel method for intraoperative margin assessment was developed by applying a thin flexible scintillating film to specimens—flexible autoradiography (FAR) imaging. A single-arm, multi-centre study was conducted to evaluate the feasibility of intraoperative [18F]FDG FAR for the assessment of tumour margins in BCS. Methods: Eighty-eight patients with invasive breast cancer undergoing BCS received ≤ 300 MBq of [18F]FDG 60–180 min pre-operatively. Following surgical excision, intraoperative FAR imaging was performed using the LightPath® Imaging System. The first 16 patients were familiarisation patients; the remaining 72 patients were entered into the main study. FAR images were analysed post-operatively by three independent readers. Areas of increased signal intensity were marked, mean normalised radiances and tumour-to-tissue background (TBR) determined, agreement between histopathological margin status and FAR assessed and radiation dose to operating theatre staff measured. Subgroup analyses were performed for various covariates, with thresholds set based on ROC curves. Results: Data analysis was performed on 66 patients. Intraoperative margin assessment using FAR was completed on 385 margins with 46.2% sensitivity, 81.7% specificity, 8.1% PPV, 97.7% NPV and an overall accuracy of 80.5%, detecting both invasive carcinoma and DCIS. A subgroup analysis based on [18F]FDG activity present at time of imaging revealed an increased sensitivity (71.4%), PPV (9.3%) and NPV (98.4%) in the high-activity cohort with mean tumour radiance and TBR of 126.7 ± 45.7 photons/s/cm2/sr/MBq and 2.1 ± 0.5, respectively. Staff radiation exposure was low (38.2 ± 38.1 µSv). Conclusion: [18F]FDG FAR is a feasible and safe technique for intraoperative tumour margin assessment. Further improvements in diagnostic performance require optimising the method for scintillator positioning and/or the use of targeted radiopharmaceuticals. Trial registration: Identifier: NCT02666079. Date of registration: 28 January 2016. URL: https://clinicaltrials.gov/ct2/show/NCT02666079. ISRCTN registry: Reference: ISRCTN17778965. Date of registration: 11 February 2016. URL: http://www.isrctn.com/ISRCTN17778965.
- 18 March 2021
- Published by Springer Nature in EJNMMI Research
- Vol. 11 (1) , 1-12
Open AccessIntraoperative [18F]FDG flexible autoradiography for tumour margin assessment in breast-conserving surgery: a first-in-human multicentre feasibility study
Introduction: In women undergoing breast-conserving surgery (BCS), 20–25% require a re-operation as a result of incomplete tumour resection. An intra-operative technique to assess tumour margins accurately would be a major advantage. A novel method for intraoperative margin assessment was developed by applying a thin flexible scintillating film to specimens—flexible autoradiography (FAR) imaging. A single-arm, multi-centre study was conducted to evaluate the feasibility of intraoperative [18F]FDG FAR for the assessment of tumour margins in BCS. Methods: Eighty-eight patients with invasive breast cancer undergoing BCS received ≤ 300 MBq of [18F]FDG 60–180 min pre-operatively. Following surgical excision, intraoperative FAR imaging was performed using the LightPath® Imaging System. The first 16 patients were familiarisation patients; the remaining 72 patients were entered into the main study. FAR images were analysed post-operatively by three independent readers. Areas of increased signal intensity were marked, mean normalised radiances and tumour-to-tissue background (TBR) determined, agreement between histopathological margin status and FAR assessed and radiation dose to operating theatre staff measured. Subgroup analyses were performed for various covariates, with thresholds set based on ROC curves. Results: Data analysis was performed on 66 patients. Intraoperative margin assessment using FAR was completed on 385 margins with 46.2% sensitivity, 81.7% specificity, 8.1% PPV, 97.7% NPV and an overall accuracy of 80.5%, detecting both invasive carcinoma and DCIS. A subgroup analysis based on [18F]FDG activity present at time of imaging revealed an increased sensitivity (71.4%), PPV (9.3%) and NPV (98.4%) in the high-activity cohort with mean tumour radiance and TBR of 126.7 ± 45.7 photons/s/cm2/sr/MBq and 2.1 ± 0.5, respectively. Staff radiation exposure was low (38.2 ± 38.1 µSv). Conclusion: [18F]FDG FAR is a feasible and safe technique for intraoperative tumour margin assessment. Further improvements in diagnostic performance require optimising the method for scintillator positioning and/or the use of targeted radiopharmaceuticals. Trial registration: Identifier: NCT02666079. Date of registration: 28 January 2016. URL: https://clinicaltrials.gov/ct2/show/NCT02666079. ISRCTN registry: Reference: ISRCTN17778965. Date of registration: 11 February 2016. URL: http://www.isrctn.com/ISRCTN17778965.
- Open Access
- 24 October 2019
- Published by Springer Nature in EJNMMI Physics
- Vol. 6 (1) , 1-13
Performance evaluation of Cerenkov luminescence imaging: a comparison of 68Ga with 18F
Background: Cerenkov Luminescence Imaging (CLI) is an emerging technology for intraoperative margin assessment. Previous research only evaluated radionuclide 18-Fluorine (18F); however, for future applications in prostate cancer, 68-Gallium (68Ga) seems more suitable, given its higher positron energy. Theoretical calculations predict that 68Ga should offer a higher signal-to-noise ratio than 18F; this is the first experimental confirmation. The aim of this study is to investigate the technical performance of CLI by comparing 68Ga to 18F. Results: The linearity of the system, detection limit, spatial resolution, and uniformity were determined with the LightPath imaging system. All experiments were conducted with clinically relevant activity levels in vitro, using dedicated phantoms. For both radionuclides, a linear relationship between the activity concentration and detected light yield was observed (R2 = 0.99). 68Ga showed approximately 22 times more detectable Cerenkov signal compared to 18F. The detectable activity concentration after a 120 s exposure time and 2 × 2 binning of 18F was 23.7 kBq/mL and 1.2 kBq/mL for 68Ga. The spatial resolution was 1.31 mm for 18F and 1.40 mm for 68Ga. The coefficient of variance of the uniformity phantom was 0.07 for the central field of view. Conclusion: 68Ga was superior over 18F in terms of light yield and minimal detection limit. However, as could be expected, the resolution was 0.1 mm less for 68Ga. Given the clinical constraints of an acquisition time less than 120 s and a spatial resolution < 2 mm, CLI for intraoperative margin assessment using 68Ga could be feasible.
- 24 October 2019
- Published by Springer Nature in EJNMMI Physics
- Vol. 6 (1) , 1-13
Open AccessPerformance evaluation of Cerenkov luminescence imaging: a comparison of 68Ga with 18F
Background: Cerenkov Luminescence Imaging (CLI) is an emerging technology for intraoperative margin assessment. Previous research only evaluated radionuclide 18-Fluorine (18F); however, for future applications in prostate cancer, 68-Gallium (68Ga) seems more suitable, given its higher positron energy. Theoretical calculations predict that 68Ga should offer a higher signal-to-noise ratio than 18F; this is the first experimental confirmation. The aim of this study is to investigate the technical performance of CLI by comparing 68Ga to 18F. Results: The linearity of the system, detection limit, spatial resolution, and uniformity were determined with the LightPath imaging system. All experiments were conducted with clinically relevant activity levels in vitro, using dedicated phantoms. For both radionuclides, a linear relationship between the activity concentration and detected light yield was observed (R2 = 0.99). 68Ga showed approximately 22 times more detectable Cerenkov signal compared to 18F. The detectable activity concentration after a 120 s exposure time and 2 × 2 binning of 18F was 23.7 kBq/mL and 1.2 kBq/mL for 68Ga. The spatial resolution was 1.31 mm for 18F and 1.40 mm for 68Ga. The coefficient of variance of the uniformity phantom was 0.07 for the central field of view. Conclusion: 68Ga was superior over 18F in terms of light yield and minimal detection limit. However, as could be expected, the resolution was 0.1 mm less for 68Ga. Given the clinical constraints of an acquisition time less than 120 s and a spatial resolution < 2 mm, CLI for intraoperative margin assessment using 68Ga could be feasible.
- 1 March 2019
- Published by Elsevier in European Urology Supplements
- Vol. 18 (1) , e668-e669
Cerenkov luminescence imaging for intraoperative specimen analysis: A pre-clinical evaluation
- 1 March 2019
- Published by Elsevier in European Urology Supplements
- Vol. 18 (1) , e668-e669
Cerenkov luminescence imaging for intraoperative specimen analysis: A pre-clinical evaluation