David A. Houlden
Research Subjects
David A. Houlden has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Amin Kassam
The Ottawa Hospital
2 shared publications - Brian James Murray
Division of Neurology, Department of Medicine, Sunnybrook Health Sciences Centre, University of Toronto, Ontario, Canada
1 shared publication - Chantal A. Turgeon
The Ottawa Hospital
1 shared publication Craig P. Stewart
Surgical Monitoring
1 shared publicationEkaterina Potapova
Surgical Monitoring
1 shared publicationFahad AlKherayf
1 shared publication
Latest Publications
- Open Access
- 20 July 2015
- Published by Cambridge University Press (CUP) in Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques
- Vol. 42 (5) , 317-323
Giant Somatosensory Evoked Potentials Coincident With Epileptiform Discharges in Acutely Comatose Patients
Background: The amplitude of the cortically generated somatosensory evoked potential (SSEP) is used to predict outcome in comatose patients. The relationship between epileptiform discharges and SSEP amplitude has not been elucidated in those patients.Methods: Bilateral median nerve SSEP and electroencephalograph (EEG) studies were performed in a comatose patient (patient 1) 1 day after cardiac surgery and repeated 4 days later. He had tranexamic acid administered before and during surgery. Another comatose patient (patient 2) had the same studies performed 1 day after sustaining 10 minutes of pulseless electrical cardiac activity.Results: Both comatose patients had epileptiform discharges (on EEG) that were coincident with giant cortically generated SSEPs. In patient 1, the EEG and SSEP studies repeated 5 days postoperatively showed no epileptiform discharges, and the cortically generated SSEP amplitude was decreased (normalized) compared with that obtained one day postoperatively. He emerged from coma and had a good recovery. Patient 2 died shortly after EEG and SSEP testing.Conclusions: Epileptiform discharges were associated with giant cortically generated median nerve SSEP amplitude (tranexamic acid was implicated in patient 1 and anoxic brain injury in patient 2). Accordingly, those who use the amplitude of cortically generated SSEPs for predicting outcome in comatose patients should consider the presence of epileptiform discharges (detected by EEG) as a potential confounding factor.
- 20 July 2015
- Published by Cambridge University Press (CUP) in Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques
- Vol. 42 (5) , 317-323
Open AccessGiant Somatosensory Evoked Potentials Coincident With Epileptiform Discharges in Acutely Comatose Patients
Background: The amplitude of the cortically generated somatosensory evoked potential (SSEP) is used to predict outcome in comatose patients. The relationship between epileptiform discharges and SSEP amplitude has not been elucidated in those patients.Methods: Bilateral median nerve SSEP and electroencephalograph (EEG) studies were performed in a comatose patient (patient 1) 1 day after cardiac surgery and repeated 4 days later. He had tranexamic acid administered before and during surgery. Another comatose patient (patient 2) had the same studies performed 1 day after sustaining 10 minutes of pulseless electrical cardiac activity.Results: Both comatose patients had epileptiform discharges (on EEG) that were coincident with giant cortically generated SSEPs. In patient 1, the EEG and SSEP studies repeated 5 days postoperatively showed no epileptiform discharges, and the cortically generated SSEP amplitude was decreased (normalized) compared with that obtained one day postoperatively. He emerged from coma and had a good recovery. Patient 2 died shortly after EEG and SSEP testing.Conclusions: Epileptiform discharges were associated with giant cortically generated median nerve SSEP amplitude (tranexamic acid was implicated in patient 1 and anoxic brain injury in patient 2). Accordingly, those who use the amplitude of cortically generated SSEPs for predicting outcome in comatose patients should consider the presence of epileptiform discharges (detected by EEG) as a potential confounding factor.
- Open Access
- 15 November 2013
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 28 (3) , 275-285
Intraoperative flash VEPs are reproducible in the presence of low amplitude EEG
Flash visual evoked potentials (FVEPs) are often irreproducible during surgery. We assessed the relationship between intraoperative FVEP reproducibility and EEG amplitude. Left then right eyes were stimulated by goggle light emitting diodes, and FVEPs were recorded from Oz–Fz′ (International 10-20 system) in 12 patients. Low cut filters were ≤5 Hz in all patients; two patients also had recordings using 10 and 30 Hz. The reproducibility of FVEP and the amplitude of the concomitant EEG from C4′–Fz were measured. Nine patients had low amplitude EEG (50 μV); FVEPs were absent from three of four eyes with normal pre-operative vision (the other normal eye had a present but irreproducible FVEP). Raising the low cut filter to 10 and 30 Hz (in two patients) progressively reduced EEG and FVEP amplitude, reduced amplifier blocking time and improved FVEP reproducibility. FVEPs were more reproducible in the presence of low amplitude EEG than high amplitude EEG. This is the first report describing the effect of EEG amplitude on FVEP reproducibility during surgery.
- 15 November 2013
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 28 (3) , 275-285
Open AccessIntraoperative flash VEPs are reproducible in the presence of low amplitude EEG
Flash visual evoked potentials (FVEPs) are often irreproducible during surgery. We assessed the relationship between intraoperative FVEP reproducibility and EEG amplitude. Left then right eyes were stimulated by goggle light emitting diodes, and FVEPs were recorded from Oz–Fz′ (International 10-20 system) in 12 patients. Low cut filters were ≤5 Hz in all patients; two patients also had recordings using 10 and 30 Hz. The reproducibility of FVEP and the amplitude of the concomitant EEG from C4′–Fz were measured. Nine patients had low amplitude EEG (50 μV); FVEPs were absent from three of four eyes with normal pre-operative vision (the other normal eye had a present but irreproducible FVEP). Raising the low cut filter to 10 and 30 Hz (in two patients) progressively reduced EEG and FVEP amplitude, reduced amplifier blocking time and improved FVEP reproducibility. FVEPs were more reproducible in the presence of low amplitude EEG than high amplitude EEG. This is the first report describing the effect of EEG amplitude on FVEP reproducibility during surgery.
- 1 June 2013
- Vol. 53 (2) , 121-41
Intraoperative neurophysiological monitoring during circulatory arrest using deep hypothermia: A case report during brain aneurysm clipping.
Neuroprotection is the main goal during procedures that involve circulatory arrest using hypothermia. This case report describes the role intraoperative neurophysiological monitoring (IONM) plays and describes the sensitivity of specific modalities used intraoperatively to identify changes and intervene in a timely manner Understanding the contributing factors and IONM changes during hypothermia helps the neuroelectrophysiology monitorist and the surgeon to provide optimal care while minimizing morbidity. In this report we describe the role of IONM from the monitorist's perspective, describing the surgical procedure and the sequence of events. This report illustrates the electrophysiological changes that occur during aneurysm clipping during cardiopulmonary arrest with deep hypothermia.
- 1 June 2013
- Vol. 53 (2) , 121-41
Intraoperative neurophysiological monitoring during circulatory arrest using deep hypothermia: A case report during brain aneurysm clipping.
Neuroprotection is the main goal during procedures that involve circulatory arrest using hypothermia. This case report describes the role intraoperative neurophysiological monitoring (IONM) plays and describes the sensitivity of specific modalities used intraoperatively to identify changes and intervene in a timely manner Understanding the contributing factors and IONM changes during hypothermia helps the neuroelectrophysiology monitorist and the surgeon to provide optimal care while minimizing morbidity. In this report we describe the role of IONM from the monitorist's perspective, describing the surgical procedure and the sequence of events. This report illustrates the electrophysiological changes that occur during aneurysm clipping during cardiopulmonary arrest with deep hypothermia.
- 1 December 2012
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 29 (6) , 509-513
Optimal Intraoperative Somatosensory Evoked Potential Stimulus Intensity Can Be Determined by Nerve Action Potential Amplitude
Purpose: Muscle twitch threshold has been used to determine optimal stimulus intensity for somatosensory evoked potentials but neuromuscular blockade precludes the use of muscle twitch during surgery. Accordingly, nerve action potential (NAP) amplitude was investigated as a surrogate to muscle twitch. Methods: The ulnar and tibial nerves were stimulated at the wrist and ankle, respectively, in 27 patients undergoing spine and brain surgery. After neuromuscular blockade was gone, the stimulus intensity for just maximal NAP amplitude recorded from Erb's point and the popliteal fossa was compared with the stimulus intensity for hypothenar and plantar foot muscle twitch threshold (times two), respectively (Wilcoxon matched pairs test). Results: There was no significant difference between stimulus intensity for just maximal Erb’s point and popliteal fossa NAP amplitude when compared with stimulus intensity for hypothenar and plantar foot twitch threshold (times two), respectively. Eight patients required more than twitch intensity (times two) to obtain maximum NAP. Conclusions: The NAP amplitude may be used to determine optimal somatosensory evoked potential stimulus intensity when muscle twitch is not visible. This method should improve the success of intraoperative somatosensory evoked potential monitoring and decrease erroneous interpretation.
- 1 December 2012
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 29 (6) , 509-513
Optimal Intraoperative Somatosensory Evoked Potential Stimulus Intensity Can Be Determined by Nerve Action Potential Amplitude
Purpose: Muscle twitch threshold has been used to determine optimal stimulus intensity for somatosensory evoked potentials but neuromuscular blockade precludes the use of muscle twitch during surgery. Accordingly, nerve action potential (NAP) amplitude was investigated as a surrogate to muscle twitch. Methods: The ulnar and tibial nerves were stimulated at the wrist and ankle, respectively, in 27 patients undergoing spine and brain surgery. After neuromuscular blockade was gone, the stimulus intensity for just maximal NAP amplitude recorded from Erb's point and the popliteal fossa was compared with the stimulus intensity for hypothenar and plantar foot muscle twitch threshold (times two), respectively (Wilcoxon matched pairs test). Results: There was no significant difference between stimulus intensity for just maximal Erb’s point and popliteal fossa NAP amplitude when compared with stimulus intensity for hypothenar and plantar foot twitch threshold (times two), respectively. Eight patients required more than twitch intensity (times two) to obtain maximum NAP. Conclusions: The NAP amplitude may be used to determine optimal somatosensory evoked potential stimulus intensity when muscle twitch is not visible. This method should improve the success of intraoperative somatosensory evoked potential monitoring and decrease erroneous interpretation.