Philippe Bourget
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Philippe Bourget has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Alexandre Amin
Clinical Pharmacy Department, HU Necker-Enfants Malades, 149 rue de Sèvres, 75743 Paris cedex 15, France
8 shared publications Fabrice Vidal
Clinical Pharmacy Department University Hospital Necker–Enfants Malades Paris France
6 shared publicationsChristophe Merlette
Clinical Pharmacy Department, HU Necker-Enfants Malades (AP-HP), Paris, France
4 shared publicationsF. Vidal
University Hospital Necker-Enfants Malades, Clinical Pharmacy Department, Paris, France
2 shared publications- Olivier Hermine
Necker Hospital, Paris, France
2 shared publications A Amin
1 shared publication
Latest Publications
- 1 January 2016
- Published by Walter de Gruyter GmbH in Pharmaceutical Technology in Hospital Pharmacy
- Vol. 1 (1)
Design and Development of a User-Friendly Motorized Apparatus for the Filling of Portable Infusion Pumps by Hospital and Homecare Health Workers
Musculoskeletal disorders (MSD) remain the most common occupational disease in the Western countries. Beside the effects on workers themselves, MSDs may lead to high costs to enterprises and the society as a whole. Among the painful or tiring positions encountered in healthcare settings, caregivers often cite the filling of portable infusion pumps (PIP). This context was conducive to achievement of the goal of the following project: the development of a motorized apparatus designed to minimize the risk of MSDs caused by repeated gestures of filling PIPs.: The development of the tool followed eleven steps including: (a) a market analysis, (b) a SWOT analysis, (c) definition of the specifications of the apparatus, and (d) a concurrent engineering methodology.: In approximately 18 months, a dynamic project group supported by a concurrent engineering methodology has designed and developed a compact and lightweight motorized apparatus able to suppress the risk of MSDs caused by manual filling of PIPs. After a mandatory step of familiarization, all involved operators have unanimously endorsed the new tool.: We believe that this new motorized apparatus may now simply and substantially alleviate occupational MSDs caused by the manually filling of PIPs. Another major benefit of this research program is the clear improvement of the intrinsically quality of therapeutic objects (TO) through the creation of a more accurate and reproducible method of PIP filling.
- 1 January 2016
- Published by Walter de Gruyter GmbH in Pharmaceutical Technology in Hospital Pharmacy
- Vol. 1 (1)
Design and Development of a User-Friendly Motorized Apparatus for the Filling of Portable Infusion Pumps by Hospital and Homecare Health Workers
Musculoskeletal disorders (MSD) remain the most common occupational disease in the Western countries. Beside the effects on workers themselves, MSDs may lead to high costs to enterprises and the society as a whole. Among the painful or tiring positions encountered in healthcare settings, caregivers often cite the filling of portable infusion pumps (PIP). This context was conducive to achievement of the goal of the following project: the development of a motorized apparatus designed to minimize the risk of MSDs caused by repeated gestures of filling PIPs.: The development of the tool followed eleven steps including: (a) a market analysis, (b) a SWOT analysis, (c) definition of the specifications of the apparatus, and (d) a concurrent engineering methodology.: In approximately 18 months, a dynamic project group supported by a concurrent engineering methodology has designed and developed a compact and lightweight motorized apparatus able to suppress the risk of MSDs caused by manual filling of PIPs. After a mandatory step of familiarization, all involved operators have unanimously endorsed the new tool.: We believe that this new motorized apparatus may now simply and substantially alleviate occupational MSDs caused by the manually filling of PIPs. Another major benefit of this research program is the clear improvement of the intrinsically quality of therapeutic objects (TO) through the creation of a more accurate and reproducible method of PIP filling.
- 17 August 2015
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 46 (12) , 1283-1290
Contribution and limits of a non‐intrusive Raman spectroscopic method compared with HPLC for routine application to pre‐delivery analytical control of two major camptothecin analogs: irinotecan and topotecan
The purpose of this study was to develop a Raman spectroscopy (RS) method as an effective tool for the non‐intrusive pre‐delivery analytical quality control (AQC) of two camptothecin analogs, i.e. irinotecan (IRI) and topotecan (TPT), which are prescribed and compounded at the hospital. Following a phase of analytical pre‐validation, based on the actual conditions of use of the analogs, the protocol was validated and compared with the reference high‐performance liquid chromatography (HPLC) method. For IRI, AQC by RS has been validated in ranges from 0.94 to 3.27 mg/ml in saline solutions and from 0.89 to 3.30 mg/ml in dextrose solutions. These ranges recover the entire therapeutic concentrations encountered in clinical practice, i.e. 1.08–2.8 mg/ml. The RS and HPLC methods were validated by calculating the accuracy profile and provided excellent results for the analytical validation key criteria. The Spearman and Kendall correlation tests (p‐value < 1.10−11) and the statistical studies performed on the Bland and Altman graphs confirm a strong correlation between RS and HPLC results. However, we show that a routine apparatus is unable to quantify TPT therapeutic concentrations ranging between 25 and 50 µg/ml but that a sufficiently powerful RS bench is able to detect and quantify TPT. Overall, these results confirm the potential of the RS option for future innovative applications. Owing to its analytical and practical qualities, this promising method contributes to the improvement of the safety of the medication circuit at the hospital and to the protection of caregivers and their working environment. Copyright © 2015 John Wiley & Sons, Ltd.
- 17 August 2015
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 46 (12) , 1283-1290
Contribution and limits of a non‐intrusive Raman spectroscopic method compared with HPLC for routine application to pre‐delivery analytical control of two major camptothecin analogs: irinotecan and topotecan
The purpose of this study was to develop a Raman spectroscopy (RS) method as an effective tool for the non‐intrusive pre‐delivery analytical quality control (AQC) of two camptothecin analogs, i.e. irinotecan (IRI) and topotecan (TPT), which are prescribed and compounded at the hospital. Following a phase of analytical pre‐validation, based on the actual conditions of use of the analogs, the protocol was validated and compared with the reference high‐performance liquid chromatography (HPLC) method. For IRI, AQC by RS has been validated in ranges from 0.94 to 3.27 mg/ml in saline solutions and from 0.89 to 3.30 mg/ml in dextrose solutions. These ranges recover the entire therapeutic concentrations encountered in clinical practice, i.e. 1.08–2.8 mg/ml. The RS and HPLC methods were validated by calculating the accuracy profile and provided excellent results for the analytical validation key criteria. The Spearman and Kendall correlation tests (p‐value < 1.10−11) and the statistical studies performed on the Bland and Altman graphs confirm a strong correlation between RS and HPLC results. However, we show that a routine apparatus is unable to quantify TPT therapeutic concentrations ranging between 25 and 50 µg/ml but that a sufficiently powerful RS bench is able to detect and quantify TPT. Overall, these results confirm the potential of the RS option for future innovative applications. Owing to its analytical and practical qualities, this promising method contributes to the improvement of the safety of the medication circuit at the hospital and to the protection of caregivers and their working environment. Copyright © 2015 John Wiley & Sons, Ltd.
- 1 October 2014
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 474 (1-2) , 193-201
Routine application of Raman spectroscopy in the quality control of hospital compounded ganciclovir
- 1 October 2014
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 474 (1-2) , 193-201
Routine application of Raman spectroscopy in the quality control of hospital compounded ganciclovir
- 1 May 2014
- Published by American Society for Microbiology in Antimicrobial Agents and Chemotherapy
- Vol. 58 (5) , 2849-2855
How To Minimize Toxic Exposure to Pyridine during Continuous Infusion of Ceftazidime in Patients with Cystic Fibrosis?
Ceftazidime is particularly efficient against Pseudomonas aeruginosa in cystic fibrosis patients. Thus, the spontaneous production of pyridine, which is a toxic product, raises some concern. Our aim was to examine the kinetics of degradation of ceftazidime in portable infusion pumps either at 4°C, 22°C, or 33°C and to propose some recommendations in order to reduce the pyridine exposure. Two administration models were studied in vitro . In model 1, we administered 12 g of ceftazidime infused over 23 h (once-daily infusion) compared to 6 g infused over 11.5 h in model 2 (twice-daily regimen). Samples were collected at 0 h and then every 4 and 2 h after the shaping of portable infusion pumps in models 1 and 2, respectively. Both ceftazidime and pyridine were analyzed using an ultraviolet high-performance liquid chromatograph. Production of pyridine is highly depending on the temperature. The in situ production of pyridine per day of treatment decreases at a ratio close to 1/6 and 1/3 between 33°C and 4°C in models 1 and 2, respectively. Regardless of the conditions, the production of pyridine is significantly lower in model 2, whereas the total delivery amount of ceftazidime is significantly higher at 4°C and 33°C compared to that in model 1. According to a the precautionary principle, these findings lead to three major recommendations: (i) exposing a solution of ceftazidime to over 22°C should be strictly avoided, (ii) a divided dose of 6 g over 11.5 h instead of a once-daily administration is preferred, and (iii) infusion should be administered immediately after reconstitution.
- 1 May 2014
- Published by American Society for Microbiology in Antimicrobial Agents and Chemotherapy
- Vol. 58 (5) , 2849-2855
How To Minimize Toxic Exposure to Pyridine during Continuous Infusion of Ceftazidime in Patients with Cystic Fibrosis?
Ceftazidime is particularly efficient against Pseudomonas aeruginosa in cystic fibrosis patients. Thus, the spontaneous production of pyridine, which is a toxic product, raises some concern. Our aim was to examine the kinetics of degradation of ceftazidime in portable infusion pumps either at 4°C, 22°C, or 33°C and to propose some recommendations in order to reduce the pyridine exposure. Two administration models were studied in vitro . In model 1, we administered 12 g of ceftazidime infused over 23 h (once-daily infusion) compared to 6 g infused over 11.5 h in model 2 (twice-daily regimen). Samples were collected at 0 h and then every 4 and 2 h after the shaping of portable infusion pumps in models 1 and 2, respectively. Both ceftazidime and pyridine were analyzed using an ultraviolet high-performance liquid chromatograph. Production of pyridine is highly depending on the temperature. The in situ production of pyridine per day of treatment decreases at a ratio close to 1/6 and 1/3 between 33°C and 4°C in models 1 and 2, respectively. Regardless of the conditions, the production of pyridine is significantly lower in model 2, whereas the total delivery amount of ceftazidime is significantly higher at 4°C and 33°C compared to that in model 1. According to a the precautionary principle, these findings lead to three major recommendations: (i) exposing a solution of ceftazidime to over 22°C should be strictly avoided, (ii) a divided dose of 6 g over 11.5 h instead of a once-daily administration is preferred, and (iii) infusion should be administered immediately after reconstitution.
- 1 March 2014
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 91, 176-184
Comparison of Raman spectroscopy vs. high performance liquid chromatography for quality control of complex therapeutic objects: Model of elastomeric portable pumps filled with a fluorouracil solution
- 1 March 2014
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 91, 176-184
Comparison of Raman spectroscopy vs. high performance liquid chromatography for quality control of complex therapeutic objects: Model of elastomeric portable pumps filled with a fluorouracil solution
- 1 September 2013
- No. 3,p. 32-45
[Raman spectroscopy applied to analytical quality control of injectable drugs: analytical evaluation and comparative economic versus HPLC and UV / visible-FTIR].
In France, central IV admixture of chemotherapy (CT) treatments at the hospital is now required by law. We have previously shown that the shaping of Therapeutic Objects (TOs) could profit from an Analytical Quality Assurance (AQA), closely linked to the batch release, for the three key parameters: identity, purity, and initial concentration of the compound of interest. In the course of recent and diversified works, we showed the technical superiority of non-intrusive Raman Spectroscopy (RS) vs. any other analytical option and, especially for both HPLC and vibrational method using a UV/visible-FTIR coupling. An interconnected qualitative and economic assessment strongly helps to enrich these relevant works. The study compares in operational situation, the performance of three analytical methods used for the AQC of TOs. We used: a) a set of evaluation criteria, b) the depreciation tables of the machinery, c) the cost of disposables, d) the weight of equipment and technical installations, e) the basic accounting unit (unit of work) and its composite costs (Euros), which vary according to the technical options, the weight of both human resources and disposables; finally, different combinations are described. So, the unit of work can take 12 different values between 1 and 5.5 Euros, and we provide various recommendations. A qualitative evaluation grid constantly places the SR technology as superior or equal to the 2 other techniques currently available. Our results demonstrated: a) the major interest of the non-intrusive AQC performed by RS, especially when it is not possible to analyze a TO with existing methods e.g. elastomeric portable pumps, and b) the high potential for this technique to be a strong contributor to the security of the medication circuit, and to fight the iatrogenic effects of drugs especially in the hospital. It also contributes to the protection of all actors in healthcare and of their working environment.
- 1 September 2013
- No. 3,p. 32-45
[Raman spectroscopy applied to analytical quality control of injectable drugs: analytical evaluation and comparative economic versus HPLC and UV / visible-FTIR].
In France, central IV admixture of chemotherapy (CT) treatments at the hospital is now required by law. We have previously shown that the shaping of Therapeutic Objects (TOs) could profit from an Analytical Quality Assurance (AQA), closely linked to the batch release, for the three key parameters: identity, purity, and initial concentration of the compound of interest. In the course of recent and diversified works, we showed the technical superiority of non-intrusive Raman Spectroscopy (RS) vs. any other analytical option and, especially for both HPLC and vibrational method using a UV/visible-FTIR coupling. An interconnected qualitative and economic assessment strongly helps to enrich these relevant works. The study compares in operational situation, the performance of three analytical methods used for the AQC of TOs. We used: a) a set of evaluation criteria, b) the depreciation tables of the machinery, c) the cost of disposables, d) the weight of equipment and technical installations, e) the basic accounting unit (unit of work) and its composite costs (Euros), which vary according to the technical options, the weight of both human resources and disposables; finally, different combinations are described. So, the unit of work can take 12 different values between 1 and 5.5 Euros, and we provide various recommendations. A qualitative evaluation grid constantly places the SR technology as superior or equal to the 2 other techniques currently available. Our results demonstrated: a) the major interest of the non-intrusive AQC performed by RS, especially when it is not possible to analyze a TO with existing methods e.g. elastomeric portable pumps, and b) the high potential for this technique to be a strong contributor to the security of the medication circuit, and to fight the iatrogenic effects of drugs especially in the hospital. It also contributes to the protection of all actors in healthcare and of their working environment.
- 1 December 2012
- Published by Elsevier in Pathologie Biologie
- Vol. 60 (6) , 369-379
La Spectroscopie Raman (SR) : un nouvel outil adapté au contrôle de qualité analytique des préparations injectables en milieu de soins. Comparaison de la SR aux techniques CLHP et UV/visible-IRTF appliquée à la classe des anthracyclines en cancérologie
- 1 December 2012
- Published by Elsevier in Pathologie Biologie
- Vol. 60 (6) , 369-379
La Spectroscopie Raman (SR) : un nouvel outil adapté au contrôle de qualité analytique des préparations injectables en milieu de soins. Comparaison de la SR aux techniques CLHP et UV/visible-IRTF appliquée à la classe des anthracyclines en cancérologie