Thomas Yeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thomas Yeh has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Michael R. Recto
Division of Pediatric Cardiology, University of Louisville, Louisville, Kentucky 40202-3830, USA
2 shared publications Charles Fox
1 shared publicationEdwin Frieberg
1 shared publicationMatthew Stohs
1 shared publicationMaura Steed
Department of Surgery, Tulane University, New Orleans, Louisiana; Department of Pediatrics, Tulane University, New Orleans, LA 70112, USA
1 shared publicationMichael Bousamra
1 shared publication
Latest Publications
- 1 November 2012
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 94 (5) , 1714-1716
Ventricular Septal Avulsion and Ventricular Septal Defect After Blunt Trauma
- 1 November 2012
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 94 (5) , 1714-1716
Ventricular Septal Avulsion and Ventricular Septal Defect After Blunt Trauma
- 1 April 2012
- Vol. 24 (4) , 145-50
Contraction of the Amplatzer Vascular Plug I and II in pulmonary artery and systemic venous collateral vessels is safe and of no hemodynamic or vascular consequence in short- and mid-term follow-up.
The Amplatzer Vascular Plug (AVP) I and AVP II have been used successfully to occlude moderate-large venous collateral vessels (VC) and pulmonary arteriovenous malformations (PAVM) in children and adults with congenital heart disease. To report our experience in 4 patients who underwent device occlusion of systemic venous collaterals (3 patients) and device closure of pulmonary arteriovenous malformation (1 patient) that developed contraction of the AVP. The records of all patients who underwent device occlusion utilizing both AVP I and AVP II between November 2006 and January 2011 were retrospectively reviewed. All available follow-up chest x-rays were reviewed and compared with angiograms obtained post device occlusion. A device 30%-50% larger than the targeted vessel was utilized to occlude the vessel. Four patients were identified with a mean age of 21 years (range, 7 years and 2 months-52 years) and mean weight of 60.6 kg (range, 15.3-131.5 kg). Two patients received AVP I and 2 patients received AVP II. One patient who received the 12 mm AVP I showed moderate contraction. The 3 other patients who received AVP I (6 mm) and AVP II (10 mm, 12 mm) all demonstrated device contraction to the original shape of the device. Mean follow-up time of 24 months (range, 12-40 months) has shown no evidence of hemodynamic or vascular compromise. Short to mid-term follow-up indicate that contraction of AVP I and AVP II is safe with no evidence of hemodynamic or vascular compromise. Continued long-term follow-up is warranted.
- 1 April 2012
- Vol. 24 (4) , 145-50
Contraction of the Amplatzer Vascular Plug I and II in pulmonary artery and systemic venous collateral vessels is safe and of no hemodynamic or vascular consequence in short- and mid-term follow-up.
The Amplatzer Vascular Plug (AVP) I and AVP II have been used successfully to occlude moderate-large venous collateral vessels (VC) and pulmonary arteriovenous malformations (PAVM) in children and adults with congenital heart disease. To report our experience in 4 patients who underwent device occlusion of systemic venous collaterals (3 patients) and device closure of pulmonary arteriovenous malformation (1 patient) that developed contraction of the AVP. The records of all patients who underwent device occlusion utilizing both AVP I and AVP II between November 2006 and January 2011 were retrospectively reviewed. All available follow-up chest x-rays were reviewed and compared with angiograms obtained post device occlusion. A device 30%-50% larger than the targeted vessel was utilized to occlude the vessel. Four patients were identified with a mean age of 21 years (range, 7 years and 2 months-52 years) and mean weight of 60.6 kg (range, 15.3-131.5 kg). Two patients received AVP I and 2 patients received AVP II. One patient who received the 12 mm AVP I showed moderate contraction. The 3 other patients who received AVP I (6 mm) and AVP II (10 mm, 12 mm) all demonstrated device contraction to the original shape of the device. Mean follow-up time of 24 months (range, 12-40 months) has shown no evidence of hemodynamic or vascular compromise. Short to mid-term follow-up indicate that contraction of AVP I and AVP II is safe with no evidence of hemodynamic or vascular compromise. Continued long-term follow-up is warranted.
- 1 October 2003
- Vol. 15 (10) , 594-6
Left atrial thrombus formation on a CardioSeal Septal Occlusion device in a patient with elevated factor VIII: resolution with medical therapy.
We describe a case of thrombus formation on the left atrial disc of a CardioSeal Septal Occlusion device 14 days after transcatheter closure of a patent foramen ovale in a patient with a history of multiple cryptogenic strokes. Work-up to rule out the presence of a hypercoagulable state prior to device closure demonstrated an elevated factor VIII level. Medical therapy with heparin and aspirin was initiated, with subsequent clot resolution.
- 1 October 2003
- Vol. 15 (10) , 594-6
Left atrial thrombus formation on a CardioSeal Septal Occlusion device in a patient with elevated factor VIII: resolution with medical therapy.
We describe a case of thrombus formation on the left atrial disc of a CardioSeal Septal Occlusion device 14 days after transcatheter closure of a patent foramen ovale in a patient with a history of multiple cryptogenic strokes. Work-up to rule out the presence of a hypercoagulable state prior to device closure demonstrated an elevated factor VIII level. Medical therapy with heparin and aspirin was initiated, with subsequent clot resolution.
- 1 October 2002
- Vol. 14 (10) , 624-9
Late superior vena cava perforation and aortic laceration after stenting to treat superior vena cava syndrome secondary to fibrosing mediastinitis.
We describe a case of late perforation of the superior vena cava and laceration of the ascending aorta after stent implantation for superior vena cava syndrome. The etiology of the late perforation is unclear, and could be secondary to either flaring of the trailing edge of the stent or chest trauma.
- 1 October 2002
- Vol. 14 (10) , 624-9
Late superior vena cava perforation and aortic laceration after stenting to treat superior vena cava syndrome secondary to fibrosing mediastinitis.
We describe a case of late perforation of the superior vena cava and laceration of the ascending aorta after stent implantation for superior vena cava syndrome. The etiology of the late perforation is unclear, and could be secondary to either flaring of the trailing edge of the stent or chest trauma.