Hamid Ghanbari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hamid Ghanbari has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Hakan Oral
Cardiac Arrhythmia Service, University of Michigan, Ann Arbor, MI
6 shared publications Craig Alpert
3 shared publicationsEric Good
From the Cardiovascular Medicine, University of Michigan, Ann Arbor, MI
2 shared publications- Mislav Vrsalović
Department of Cardiovascular Diseases, University of Zagreb School of Medicine, University Hospital Centre Sestre Milosrdnice , Zagreb
2 shared publications - Scott L. Hummel
Department of Internal Medicine, Division of Cardiovascular Medicine, University of Michigan , Ann Arbor, Michigan
2 shared publications Theodore J. Kolias
2 shared publications
Latest Publications
- 18 May 2015
- Published by Medicinska Naklada d.o.o. in Cardiologia Croatica
- Vol. 10 (3-4) , 68
Left atrial global longitudinal strain predicts atrial fibrillation recurrence in patients with paroxysmal and persistent atrial fibrillation and preserved ejection fraction treated with first catheter ablation.
- 18 May 2015
- Published by Medicinska Naklada d.o.o. in Cardiologia Croatica
- Vol. 10 (3-4) , 68
Left atrial global longitudinal strain predicts atrial fibrillation recurrence in patients with paroxysmal and persistent atrial fibrillation and preserved ejection fraction treated with first catheter ablation.
- Open Access
- 30 January 2015
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 4 (2)
Antithrombotic Therapy and Outcomes After ICD Implantation in Patients With Atrial Fibrillation and Coronary Artery Disease: An Analysis From the National Cardiovascular Data Registry (NCDR) ®
Background: Management of antithrombotic agents after implantable cardioverter defibrillator implantation is challenging, particularly among patients with atrial fibrillation and coronary artery disease. Methods and Results: Using data from National Cardiovascular Data Registry ® Implantable Cardioverter Defibrillator Registry ™ linked with Medicare claims data, we identified 25 180 patients with atrial fibrillation and coronary artery disease who underwent implantable cardioverter defibrillator implantation. Patients were categorized into 5 different groups according to antithrombotic agents prescribed at discharge (any 1 antiplatelet agent [A, n=6538], dual antiplatelet therapy [ DA , n=3414], warfarin [n=5264], warfarin+A [n=7994], warfarin+ DA [n=1970]). We assessed the primary outcomes occurring within 30 days of hospital discharge. Combinations of DA (adjusted hazard ratio [ HR ]: 1.39; 95% CI : 1.03 to 1.87), warfarin+A (adjusted HR : 1.32; 95% CI : 1.03 to 1.69), and warfarin+ DA (adjusted HR : 2.03; 95% CI : 1.49 to 2.77) were associated with a higher bleeding risk. The risk of major adverse cardiovascular events was higher in patients discharged with A (adjusted HR : 1.69; 95% CI : 1.33 to 2.16), DA (adjusted HR : 2.17; 95% CI : 1.66 to 2.83), and DA +warfarin (adjusted HR : 1.61; 1.16 to 2.24). There was no association between postdischarge antithrombotic agents and thromboembolic events or device‐related complications. Conclusions: Short‐term bleeding risk and major adverse cardiovascular events differ with usage patterns of antithrombotic agents, while the risk of thromboembolic events and device‐related complications is relatively constant. These data may help clinicians balance risks and benefits when choosing antithrombotic therapy following implantable cardioverter defibrillator implantation.
- 30 January 2015
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 4 (2)
Open AccessAntithrombotic Therapy and Outcomes After ICD Implantation in Patients With Atrial Fibrillation and Coronary Artery Disease: An Analysis From the National Cardiovascular Data Registry (NCDR) ®
Background: Management of antithrombotic agents after implantable cardioverter defibrillator implantation is challenging, particularly among patients with atrial fibrillation and coronary artery disease. Methods and Results: Using data from National Cardiovascular Data Registry ® Implantable Cardioverter Defibrillator Registry ™ linked with Medicare claims data, we identified 25 180 patients with atrial fibrillation and coronary artery disease who underwent implantable cardioverter defibrillator implantation. Patients were categorized into 5 different groups according to antithrombotic agents prescribed at discharge (any 1 antiplatelet agent [A, n=6538], dual antiplatelet therapy [ DA , n=3414], warfarin [n=5264], warfarin+A [n=7994], warfarin+ DA [n=1970]). We assessed the primary outcomes occurring within 30 days of hospital discharge. Combinations of DA (adjusted hazard ratio [ HR ]: 1.39; 95% CI : 1.03 to 1.87), warfarin+A (adjusted HR : 1.32; 95% CI : 1.03 to 1.69), and warfarin+ DA (adjusted HR : 2.03; 95% CI : 1.49 to 2.77) were associated with a higher bleeding risk. The risk of major adverse cardiovascular events was higher in patients discharged with A (adjusted HR : 1.69; 95% CI : 1.33 to 2.16), DA (adjusted HR : 2.17; 95% CI : 1.66 to 2.83), and DA +warfarin (adjusted HR : 1.61; 1.16 to 2.24). There was no association between postdischarge antithrombotic agents and thromboembolic events or device‐related complications. Conclusions: Short‐term bleeding risk and major adverse cardiovascular events differ with usage patterns of antithrombotic agents, while the risk of thromboembolic events and device‐related complications is relatively constant. These data may help clinicians balance risks and benefits when choosing antithrombotic therapy following implantable cardioverter defibrillator implantation.
- 1 January 2015
- Published by Elsevier in Heart Rhythm
- Vol. 12 (1) , e4
Reply to the Editor—Incidence of sudden cardiac death in high school athletes: Implications for cardiovascular screening
- 1 January 2015
- Published by Elsevier in Heart Rhythm
- Vol. 12 (1) , e4
Reply to the Editor—Incidence of sudden cardiac death in high school athletes: Implications for cardiovascular screening
- Open Access
- 1 April 2013
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 6 (2) , 302-309
The Optimal Range of International Normalized Ratio for Radiofrequency Catheter Ablation of Atrial Fibrillation During Therapeutic Anticoagulation With Warfarin
Background—: Uninterrupted anticoagulation with warfarin during radiofrequency catheter ablation (RFA) of atrial fibrillation is associated with a lower risk of periprocedural complications than when warfarin is temporarily discontinued. However, the optimal international normalized ratio (INR) levels during RFA have not been defined. Methods and Results—: In this retrospective analysis, RFA was performed in 1133 consecutive patients (mean age, 61±10 years) with paroxysmal (550) or persistent atrial fibrillation (583). Patients were grouped based on the INR on the day of RFA. There was a quadratic relationship between the INR and bleeding and vascular complications ( P P =0.03). The prevalence of pericardial tamponade (1%) was similar at all INRs. From the quadratic model, the optimal range of INR was calculated as 2.1 to 2.5. INRs3.0 were associated with a >2-fold increase in complications, with a further steep rise beyond an INR>3.5. Concomitant clopidogrel use was associated with a significant increase in complications at all INRs (odds ratio=3.1; ±95% confidence interval, 1.4–7.4). Unfractionated heparin requirements to maintain a therapeutic activated clotting time during RFA was reduced by 50% in patients with an INR>2.0. Conclusions—: The optimal INR range during uninterrupted periprocedural anticoagulation using warfarin is narrow. Therefore, INR levels should be carefully monitored in preparation for RFA of atrial fibrillation.
- 1 April 2013
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 6 (2) , 302-309
Open AccessThe Optimal Range of International Normalized Ratio for Radiofrequency Catheter Ablation of Atrial Fibrillation During Therapeutic Anticoagulation With Warfarin
Background—: Uninterrupted anticoagulation with warfarin during radiofrequency catheter ablation (RFA) of atrial fibrillation is associated with a lower risk of periprocedural complications than when warfarin is temporarily discontinued. However, the optimal international normalized ratio (INR) levels during RFA have not been defined. Methods and Results—: In this retrospective analysis, RFA was performed in 1133 consecutive patients (mean age, 61±10 years) with paroxysmal (550) or persistent atrial fibrillation (583). Patients were grouped based on the INR on the day of RFA. There was a quadratic relationship between the INR and bleeding and vascular complications ( P P =0.03). The prevalence of pericardial tamponade (1%) was similar at all INRs. From the quadratic model, the optimal range of INR was calculated as 2.1 to 2.5. INRs3.0 were associated with a >2-fold increase in complications, with a further steep rise beyond an INR>3.5. Concomitant clopidogrel use was associated with a significant increase in complications at all INRs (odds ratio=3.1; ±95% confidence interval, 1.4–7.4). Unfractionated heparin requirements to maintain a therapeutic activated clotting time during RFA was reduced by 50% in patients with an INR>2.0. Conclusions—: The optimal INR range during uninterrupted periprocedural anticoagulation using warfarin is narrow. Therefore, INR levels should be carefully monitored in preparation for RFA of atrial fibrillation.
- 1 November 2012
- Published by Elsevier in The American Journal of Cardiology
- Vol. 110 (10) , 1482-1488
Meta-Analysis of Safety and Efficacy of Uninterrupted Warfarin Compared to Heparin-Based Bridging Therapy During Implantation of Cardiac Rhythm Devices
- 1 November 2012
- Published by Elsevier in The American Journal of Cardiology
- Vol. 110 (10) , 1482-1488
Meta-Analysis of Safety and Efficacy of Uninterrupted Warfarin Compared to Heparin-Based Bridging Therapy During Implantation of Cardiac Rhythm Devices
- 30 September 2012
- Published by Elsevier in Cardiac Electrophysiology Clinics
- Vol. 4 (3) , 353-361
Atrial Fibrillation Ablation Strategy: “Ready Made” or “Tailored”?
- 30 September 2012
- Published by Elsevier in Cardiac Electrophysiology Clinics
- Vol. 4 (3) , 353-361
Atrial Fibrillation Ablation Strategy: “Ready Made” or “Tailored”?