HLH. G. Lele

H. G. Lele

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


H. G. Lele has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Benchmarking Severe Accident Computer Codes for Heavy Water Reactor Applications

    by Thambiayah Nitheanandan, X. Cao, J.-H. Choi, D. Dupleac, D.-H. Kim, H. G. Lele, A. K. Nayak, H. P. Rammohan

    The International Atomic Energy Agency (IAEA) organized a coordinated research project (CRP) on “Benchmarking Severe Accident Computer Codes for Heavy Water Reactors (HWR) Applications,” (IAEA TECDOC Series No. 1727), and the activity was completed in 2012. This paper summarizes the results from the CRP: the selection of a severe accident sequence, definition of appropriate geometrical and boundary conditions, benchmarking code analyses, comparison of the code results, evaluation of the capabilities of existing computer codes to predict important severe accident phenomena, and suggestions for code improvements and/or new experiments to reduce uncertainties.


  • Selection of Steam Drum Level Control Method for Multiple Drum Interacting Loops Pressure Tube-Type BWR

    by Avinash J. Gaikwad, P. K. Vijayan, S. Bhartiya, R. Kumar, H. G. Lele, K. K. Vaze

    Three element Steam Drum (SD) Level Controller has been conventionally used for most of the boilers, Nuclear power plant steam generator & Boiling Water Reactor (BWRs). Based on the process dynamic studies it was found that this scheme does not work properly for an interacting, interconnected multiple loop boiling water system i.e., Advanced Heavy Water Reactor (AHWR). It is a pressure tube type light water cooled heavy water moderated Boiling Water Reactor (BWR). It has 4-inter-connected parallel loops with 113 × 4 = 452 boiling channels in the Main Heat Transport (MHT) system. These multiple (four) interconnected loops influences the Steam Drum (SD) level control adversely. Such a behavior has not been reported in the open literature. The open loop response is stable, non-oscillatory and non-diverging for a step change in the feed flow rates. Also it is not possible to maintain a steady level in all the SDs even without any external disturbance/perturbation with 4 conventional 3-element individual SD level controllers. To overcome these interactions it is proposed to interconnect all the four steam drums in the liquid & vapor regions respectively. This makes the 4 SDs behave like a single entity. The influence of the interconnect configuration & the level controller are studied in detail to find a robust solution. The response obtained for unsymmetrical core power, symmetrical power maneuvering and reactor trip transients shows that the SD levels do not diverge and quickly settle very near to the set points assigned with SD interconnect schemes.


  • Thermal Hydraulic Analysis Due to the Changes in Heat Removal for Advanced Heavy Water Reactor

    by B. Chatterjee, A. Srivastava, D. Mukhopadhyay, P. Majumdar, H. G. Lele, S. K. Gupta

    Advanced Heavy Water Reactor is natural circulation light water cooled and heavy water moderated pressure tube type of reactor. Changes in heat removal by primary heat transport system of a reactor have significant impact on various important system parameters like pressures, qualities, reactor power and flows. Increase in heat removal leads to Cooldown of the system subsequently reducing pressure, void increase and changes in power and flows of the system. Decrease in heat removal leads to warm-up of the system subsequently raising pressure, void collapse, and changes in power and flows of the system. The behaviour is complex as system under consideration is natural circulation system. Causes for events under category of increase in heat removal are mainly malfunctioning of feed water heaters, Isolation Condensers (IC) inlet valves and controllers. These events lead to cooldown of system and addition of positive reactivity addition due to void collapse. Various events considered are Feed Water System malfunctions that result in decrease in feed water temperature, inadvertent opening of IC valve, Failure of PHT Pressure Control System and Decrease in pressure controller set point to 67 bars. Causes for events under category of decrease in heat removal are mainly malfunctioning of controllers, feedwater valves and operating events like turbine trip. Functioning of passive cooling system and different valves play important role for these events. These events lead to increase in system pressure. Various events considered are Loss of normal feed water flow (multiple trains), Turbine trip without bypass without IC, Turbine trip without bypass with IC, Turbine trip with bypass without IC, Increase in PHT pressure controller set point, Decrease in level controller set point, Turbine Trip with setback, Decrease in steam flow and Class IV power failure. Changes in the system voids and pressures as a result of change in the heat removal leads to complex reactivity feedback due to coolant temperatures, void fraction and fuel temperatures. These changes in the reactor power together with void distribution change affect two-phase natural circulation flow. This paper brings out these aspects. It discusses descretisation of the system and brings out various design aspects. In this paper summary of analysis for each event is presented, various modeling complexities are brought out, evaluation of acceptance criteria is made and design implications of each event is discussed.

  • Analysis for the Case of Channel Flow and Reactivity Changes for Advanced Heavy Water Reactor

    by A. Srivastava, P. Majumdar, D. Mukhopadhyay, H. G. Lele, S. K. Gupta

    The proposed Advanced Heavy Water Reactor (AHWR) is a vertical pressure tube type boiling light water cooled and heavy water moderated reactor. One of the important passive design features of this reactor is that the heat removal is achieved through natural circulation of primary coolant at all power level with no primary coolant pumps. Decrease in coolant flow or control rod malfunction can lead to undesirable rise in clad surface temperature depending upon severity and characteristics and response of the reactor and associated systems. In this paper safety assessment of the AHWR is made due to above events of different severity. Cause for events under category of decrease in coolant flow is mainly channel blockage of different severity at different locations. There is no other reason as it is natural circulation based reactor. Effect of flow decrease can be different in different channels and at different axial locations. In this paper channel blockages of different sizes are analysed at core inlet and using slave channel approach. Changes in reactivities can occur due to inadvertent withdrawal of one or more control rods from reactor core. In this analysis one control rod assembly is assumed to be removed from core. The event is simulated by addition of 5 mk reactivity in 120 seconds depending on the speed of withdrawal of assembly. The analysis for the above events are complex due to various complex and wide range of phenomena involved during different PIEs under this category. It involves single and two phase natural circulation at different power levels, inventories and pressures, coupled neutronics and thermal hydraulics behaviour, and coupled controller and thermal hydraulics. In this paper summary of analysis for each event is presented. In this paper, various modeling complexities are brought out; evaluation of acceptance criteria is made and design implications of each event are discussed.

  • Transient Analysis for the Case of Changes in Coolant Inventory for Advanced Heavy Water Reactor

    by H. G. Lele, A. Srivastava, B. Chatterjee, A. J. Gaikwad, Rajesh Kumar, S. K. Gupta

    Safety of nuclear reactor needs to be assessed against different categories of Postulated initiating events. Advanced Heavy Water Reactor is natural circulation light water cooled and heavy water moderated pressure tube type of reactor. Inventory of the system is important parameter in determination of flow characteristics of this natural circulation reactor. In view of this, various events that cause changes in PHT system inventory are analysed in this paper. One of the reason for decrease in coolant inventory is hypothetical Loss of coolant accident (LOCA) This event is of very low probability but important from designing engineered safeguard system of a reactor. Loss of coolant accident in a nuclear reactor can cause voiding of the reactor core due to expulsion of primary coolant from break. In such, a situation the reactor core experiences very low heat removal rate from the nuclear fuel though the decay heat generation continues even after tripping of the reactor. Heat generation in the reactor core is due to various sources such as decay heat, stored heat etc, can lead to heating of fuel elements. However, Emergency core cooling systems of the reactor are actuated and prevent undesirable temperature rise. These events are called design basis events and focus is on adequacy of Emergency Core Cooling System (ECCS) and fuel integrity. The scenarios, phenomena encountered and consequences depend upon size and location of break, system characteristics, and actuation and capability of different protection and engineered safeguard systems of the reactor system. Moreover, this reactor has several passive features to ensure safety of this reactor. which are considered in analyzing these events. Events under category of decrease in coolant inventory includes loss of coolant accidents due to break at different locations of different sizes. Various locations considered in this paper are steam line, inlet header, inlet feeder, ECCS header, downcomer, pressure tube, Isolation condenser inlet header, instrument line break at inlet header and steam drum. The paper also considers scenario emerging due to malfunctions like relief valve stuck open. Causes for events under category of increase in coolant inventory are Increase in Drum level controller set point, Inadvertent valving in of Accumulators and Inadvertent valving in of Gravity driven water pool (GDWP). Last two events are not analysed as they are not possible. The analysis for the above events is complex due to various complex and wide ranges of phenomena involved during different pies under this category. It involves single and two phase natural circulation at different power levels, inventories and pressures, two-phase natural circulation under depleted inventory conditions. Coupled neutronics and thermal hydraulics behaviour, Phenomena under LOCA, phenomena during ECCS injection, direct injection into fuel rod, advanced accumulator injection., vapour pull through and coupled controller and...