LKL. J. Klein

L. J. Klein

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


L. J. Klein has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The effect of insulin on the heart

    by L. J. Klein, F. C. Visser

    Insulin infusion has been advocated in the treatment of myocardial ischaemia and myocardial infarction. There is evidence from experimental animal studies for a protective effect of high-dose insulin administration in myocardial ischaemia and myocardial infarction. In some relatively small study populations a reduction in mortality was reported in those patients who received glucose-insulin-potassium (GIK) during myocardial infarction, which was confirmed in two meta-analyses. However, it has not been possible to reproduce these positive results in large randomised clinical trials. (Neth Heart J 2010;18:255-9.)


  • The effect of insulin on the heart

    by L. J. Klein, F. C. Visser

    Positive inotropic effects of insulin were described early after the isolation of insulin from the pancreas but data on the effect of insulin on the heart are conflicting. Systemic insulin administration results in a reduction in circulating free fatty acids and an improvement in myocardial glucose uptake, which causes an efficiency improvement in the myocardial cell. There is strong evidence that insulin administration results in functional improvement in dysfunctional myocardium. (Neth Heart J 2010;18:197-201.)


  • Effects of high-dose insulin infusion on left ventricular function in normal subjects

    by L. J. Klein, C. M. C. van Campen, O. Kamp, F.C. Visser

    Background. Only a few studies have reported on the effect of high-dose insulin (HDI) infusion on cardiac function in healthy volunteers. Methods. We studied ten healthy volunteers with low-dose dobutamine (LDD, 10 µg/kg/min) echo­cardio­graphy and HDI echocardiography (insulin administration for one hour) by volume and Doppler analysis. Results. During LDD, cardiac output increased from 5.7±1.3 l/min to 9.0±2.1 l/min (pConclusion. High-dose insulin infusion results in increased cardiac output by improving systolic myocardial function. (Neth Heart J 2010;18:183-9.)


    • 1 November 2001
      • Vol. 42  (11) , 1622-9

    Image-derived input functions for determination of MRGlu in cardiac (18)F-FDG PET scans.

    by A P Van Der Weerdt, L J Klein, R Boellaard, C A Visser, F C Visser, A A Lammertsma

    Image-derived input functions (IDIF) are frequently used in cardiac (18)F-FDG PET studies for determination of the myocardial metabolic rate of glucose (MRGlu). The purpose of this study was to assess which vascular structure is most suited for defining the IDIF, using online arterial blood sampling (AS) as the gold standard. In 18 patients with ischemic heart disease, 370 MBq FDG were injected during a hyperinsulinemic euglycemic clamp. Studies were performed with a Siemens/CTI HR+ PET scanner using a dynamic scanning protocol. A fully automated blood-sampling device was used for continuous AS. IDIF were obtained using regions of interest (ROIs) of 3 different sizes defined on the left ventricle (LV), left atrium (LA), ascending aorta (AA), and descending aorta (DA). MRGlu was calculated with all input functions. Ratios between MRGlu obtained with IDIF and AS were calculated for each patient. Time-activity curves from smaller ROIs suffered more from statistical noise with only a modest reduction of spillover effects, which led to more variation in calculated MRGlu. Mean ratios of MRGlu obtained with IDIF and AS were close to 1 when AA and DA (0.97 +/- 0.07 and 1.00 +/- 0.11, respectively) were used to define the input function. However, when LA and LV were used, mean ratios were 0.81 +/- 0.06 and 0.79 +/- 0.08, respectively, reflecting a significant underestimation of MRGlu. The use of AA for defining the input function resulted in the best agreement with AS and the smallest interobserver variation. The ascending aorta is the structure of choice for defining IDIF and a large ROI (diameter, approximately 15 mm) should be used to minimize the effects of statistical noise.