MBMichael D. Beland

Michael D. Beland

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michael D. Beland has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • In Vivo Ultrasound Imaging of the Spinal Cord and Subarachnoid Space at the C1-C2 Level in Healthy Adult Subjects

    by Michael D. Beland, Abigail W. DVM McElroy, Thomas Brinker, Ziya L. Gokaslan, Petra M. Klinge

    Ultrasound (US) imaging of the spinal canal is applied in early infants before formation of posterior spine bony elements. Here, we demonstrate for the first time in adult healthy subjects that excellent visualization of intrathecal structures at the level of C1-C2 is possible by transcutaneous US in flexion, extension, and neutral head positions through the soft tissue US window between C1-C2. We show with US that the posterior subarachnoid space increases significantly in head extension. Accordingly, C1-C2 US guidance can facilitate cervical myelography. In addition, we suggest that US of the C1-C2 spine level may offer an adjunct tool to diagnosing structural abnormalities in the setting of traumatic, congenital, or degenerative pathologies of the craniocervical junction.


  • Optimizing modality selection for image-guided procedures: an analysis of the challenges to ultrasound guidance

    by Michael D. Beland, Laura A. Sternick, Grayson L. Baird, Damian E. Dupuy, John J. Cronan, William W. Mayo-Smith

    Introduction Selection of the most appropriate modality for image guidance is essential for procedural success. We identified specific factors contributing to failure of ultrasound-guided procedures that were subsequently performed using CT guidance. Materials and methods This single-center, retrospective study included 164 patients who underwent a CT-guided biopsy, aspiration/drainage, or ablation after initially having the same procedure attempted unsuccessfully with ultrasound guidance. Review of the procedure images, reports, biopsy results, and clinical follow-up was performed and the reasons for inability to perform the procedure with ultrasound guidance were recorded. Patient cross-sectional area and depth to target were calculated. Differences in area and depth were compared using general linear modeling. Depth as a predictor of an unfavorable body habitus designation was modeled using logistic regression. Results US guidance was successful in the vast majority of cases (97%). Of the 164 procedures, there were 92 (56%) biopsies, 63 (38%) aspirations/drainages, and 9 (5%) ablations. The most common reason for procedure failure was poor acoustic window (83/164, 51%). Other reasons included target lesion being poorly discerned from adjacent tissue (61/164, 37%), adjacent bowel gas (34/164, 21%), body habitus (27/164, 16%), and gas-containing collection (22/164, 13%). Within the biopsy subgroup, patients for whom body habitus was a limiting factor were found to have on average a larger cross-sectional area and lesion depth relative to patients whose body habitus was not a complicating factor (p < 0.0001 and p = 0.0009). Conclusion Poor acoustic window was the most common reason for procedural failure with ultrasound guidance. In addition, as lesion depth increased, the odds that body habitus would limit the procedure also increased. If preliminary imaging suggests a limited sonographic window, particularly for deeper lesions, proceeding directly to CT guidance should be considered.


  • Preoperative High-Resolution Ultrasound for the Assessment of Malignant Central Compartment Lymph Nodes in Papillary Thyroid Cancer

    by Mamoona T. Khokhar, Kristopher M. Day, Rohit B. Sangal, Nigar N. Ahmedli, Latha R. Pisharodi, Michael D. Beland, Jack M. Monchik

    Background: The identification and removal of malignant central compartment lymph nodes (MCLN) is important to minimize the risk of persistent or recurrent local disease in patients with papillary thyroid cancer (PTC). While the diagnostic accuracy of preoperative ultrasound for the assessment of lateral compartment node metastases is well recognized, its role in the identification of central compartment node metastases in patients with PTC is less established. This study delineates the utility of high-resolution ultrasound (HUS) for the assessment of MCLN in patients with PTC. Methods: A retrospective chart review was performed of 227 consecutive patients who underwent total thyroidectomy for biopsy-proven PTC by a single endocrine surgeon in an academic tertiary care center between 2004 and 2014. Preoperative sonographic results were compared to postoperative pathology reports to determine the accuracy of HUS for the assessment of MCLN. Statistical analysis also included sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Results: HUS identified abnormal central compartment nodes in 51 (22.5%) patients. All 227 patients underwent a careful central compartment node exploration. One hundred and four (45.8%) patients had MCLN identified by surgery, of whom 65 (62.5%) had a negative preoperative central compartment HUS. The sensitivity and specificity of preoperative HUS for the assessment of MCLN were 0.38 and 0.90, respectively. The PPV and NPV were 0.76 and 0.63, with an accuracy of 0.66. Conclusion: Preoperative HUS is quite specific for the identification of MCLN in patients with PTC. The present findings emphasize, however, that a negative HUS does not obviate the need for careful exploration of the central compartment to minimize the risk of persistent or recurrent local disease.


  • Microwave ablation of focal hepatic malignancies regardless of size: A 9-year retrospective study of 64 patients

    by Erica S. Alexander, Farrah J. Wolf, Jason T. Machan, Kevin P. Charpentier, Michael D. Beland, Jason D. Iannuccilli, Richard H. Haas, Damian E. Dupuy


  • Resident Experience Increases Diagnostic Rate of Thyroid Fine-Needle Aspiration Biopsies

    by Michael D. Beland, Thomas J.T. Anderson, Michael K. Atalay, David J. Grand, John J. Cronan


  • Effect of Patient Size on Mean Sterile Water Attenuation During Multiphase CT Examinations

    by Michael D. Beland, Albert A. Scappaticci, Jason T. Machan, Walter Huda, Scott A. Collins, William W. Mayo-Smith

    OBJECTIVE. The purpose of this study was to determine the variability of attenuation measurements in a water phantom included in the FOV during multiphase 64-MDCT. SUBJECTS AND METHODS. Ninety-seven consecutively registered patients undergoing multiphase kidney and liver protocol CT of the abdomen on the same 64-MDCT scanner had a sealed water bottle placed on their anterior abdomen during the examination. Region of interest (ROI) measurements of the mean attenuation (in HU) of the water bottle were made during the unenhanced, dynamic, and delayed phases of contrast enhancement. Generalized estimating equations were used to model mean attenuation in the ROI as a function of cross-sectional patient area, contrast phase, and protocol. Day of month and time of day were covariates. A phantom was created to model the patient study. RESULTS. The mean attenuation values in the water bottle ROIs were −13.1 HU for the kidney protocol and −9.1 HU for the liver protocol in the unenhanced phase, −11.7 HU for the kidney and −9.5 HU for the liver protocol in the dynamic phase, and −11.9 HU for the kidney and 11.0 HU for the liver protocol in the delayed phase. Kidney protocol water bottle ROI attenuation values were lower than the liver values (p = 0.04). In all phases with both protocols, the values differed from 0 HU (all p < 0.0001). Water bottle ROI attenuation decreased as patient cross-sectional area increased (−0.01 HU/cm2, p < 0.0001). Three patients had absolute water bottle attenuation changes greater than 20 HU between phases. Day of the month (p = 0.08) and time of day (p = 0.93) were not significant factors. Phantom data supported the study findings. CONCLUSION. The mean attenuation of water decreased as patient diameter increased. Both artifactual enhancement and decrease in enhancement greater than 20 HU were found in three larger patients.


    • 1 March 2013
      • Vol. 96  (3) , 50-2

    Phlegmonous colitis associated with advanced liver disease: case report and novel radiological signs.

    by Michael D Beland, Carlos Esteva, William Kim, John J Cronan

  • Principles of Cryoablation

    by Nicholas Kujala, Michael D. Beland