Martin C. Freund
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Martin C. Freund has a total of 138 co-authors. Here are the top co-authors by number of shared publications:
- Werner Jaschke
Department of Radiology, Medical University Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria
4 shared publications Alfred Koenigsrainer
Department of General Surgery and Transplant Surgery, Leopold-Franzens University, Innsbruck A-6020, Austria
3 shared publicationsKarin M. Unsinn
Department of Radiology, Leopold-Franzens University, Anichstrasse 35, Innsbruck A-6020, Austria
3 shared publicationsEva M. Gassner
Department of Radiology, Leopold-Franzens University, Anichstrasse 35, Innsbruck A-6020, Austria
2 shared publicationsMichael Rieger
Department of Radiology, Leopold-Franzens University, Anichstrasse 35, Innsbruck A-6020, Austria
2 shared publicationsRaimund Margreiter
Department of General Surgery and Transplant Surgery, Leopold-Franzens University, Innsbruck A-6020, Austria
2 shared publications
Latest Publications
- 1 January 2008
- Published by Elsevier
Contributors
- 1 April 2004
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 182 (4) , 919-925
Spectrum of Imaging Findings After Pancreas Transplantation with Enteric Exocrine Drainage: Part 2, Posttransplantation Complications
- 1 April 2004
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 182 (4) , 919-925
Spectrum of Imaging Findings After Pancreas Transplantation with Enteric Exocrine Drainage: Part 2, Posttransplantation Complications
- 1 April 2004
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 182 (4) , 911-917
Spectrum of Imaging Findings After Pancreas Transplantation with Enteric Exocrine Drainage: Part 1, Posttransplantation Anatomy
- 1 April 2004
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 182 (4) , 911-917
Spectrum of Imaging Findings After Pancreas Transplantation with Enteric Exocrine Drainage: Part 1, Posttransplantation Anatomy
- 1 October 2003
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 181 (4) , 1133-1138
Spectrum of Imaging Findings After Pediatric Liver Transplantation: Part 1, Posttransplantation Anatomy
- 1 October 2003
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 181 (4) , 1133-1138
Spectrum of Imaging Findings After Pediatric Liver Transplantation: Part 1, Posttransplantation Anatomy
- 1 January 2003
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 180 (1) , 233-239
Volume-Rendered Multidetector CT Angiography: Noninvasive Follow-Up of Patients Treated with Renal Artery Stents
OBJECTIVE. The purpose of our study was to evaluate the role of multidetector CT (MDCT) angiography with volume rendering for estimating the patency of renal artery stents. SUBJECTS AND METHODS. In 16 patients, 16 renal artery stents were evaluated with MDCT renal angiography and digital subtraction angiography (DSA). CT data were evaluated using multiplanar volume reformations and the volume-rendering algorithm with three different volume-rendered parameter settings (low-to-high, high-to-low, and high—low—high opacity transfer functions: VRLH, VRHL, and VRVE, respectively). Targeted images of each stent were rendered in paraaxial and paracoronal planes and were interactively interpreted. The overall restenosis severity was measured on postprocessed paraaxial and paracoronal images and compared with that obtained on DSA using linear regression analysis. Image quality and lumen delineation on rendered images were also compared using Wilcoxon's signed rank test. RESULTS. Eight restenoses were identified on DSA. Correlations between restenosis severity measured with DSA and those measured with MDCT were significant (p < 0.001). Volume rendering with VRHL allowed the best correlation with DSA (reviewer 1, r2 = 0.86; reviewer 2, r2 = 0.94) and was significantly better than multiplanar volume reformations (p = 0.028). Overall image quality was high with all rendering techniques and with no significant differences (p > 0.59, for all comparisons). Stent lumen was well delineated with volume-rendering modalities; however, VRHL was significantly better than VRLH (p = 0.033). CONCLUSION. Volume-rendered MDCT angiography enabled high-quality three-dimensional reproducible evaluation of the patency of implanted renal artery stents. Volume rendering with VRHL achieved the best performance.
- 1 January 2003
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 180 (1) , 233-239
Volume-Rendered Multidetector CT Angiography: Noninvasive Follow-Up of Patients Treated with Renal Artery Stents
OBJECTIVE. The purpose of our study was to evaluate the role of multidetector CT (MDCT) angiography with volume rendering for estimating the patency of renal artery stents. SUBJECTS AND METHODS. In 16 patients, 16 renal artery stents were evaluated with MDCT renal angiography and digital subtraction angiography (DSA). CT data were evaluated using multiplanar volume reformations and the volume-rendering algorithm with three different volume-rendered parameter settings (low-to-high, high-to-low, and high—low—high opacity transfer functions: VRLH, VRHL, and VRVE, respectively). Targeted images of each stent were rendered in paraaxial and paracoronal planes and were interactively interpreted. The overall restenosis severity was measured on postprocessed paraaxial and paracoronal images and compared with that obtained on DSA using linear regression analysis. Image quality and lumen delineation on rendered images were also compared using Wilcoxon's signed rank test. RESULTS. Eight restenoses were identified on DSA. Correlations between restenosis severity measured with DSA and those measured with MDCT were significant (p < 0.001). Volume rendering with VRHL allowed the best correlation with DSA (reviewer 1, r2 = 0.86; reviewer 2, r2 = 0.94) and was significantly better than multiplanar volume reformations (p = 0.028). Overall image quality was high with all rendering techniques and with no significant differences (p > 0.59, for all comparisons). Stent lumen was well delineated with volume-rendering modalities; however, VRHL was significantly better than VRLH (p = 0.033). CONCLUSION. Volume-rendered MDCT angiography enabled high-quality three-dimensional reproducible evaluation of the patency of implanted renal artery stents. Volume rendering with VRHL achieved the best performance.