Reza S. Abhari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Reza S. Abhari has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Benoit Laveau
Laboratory for Energy Conversion, ETH Zurich, Sonnegstrasse 3, Zurich 8006, Switzerland
1 shared publication Ewald Lutum
MTU Aero Engines AG, Dachauer Strasse 665, Munich D-80995, Germany
1 shared publication- Martin G. Rose
Stuttgart University, Stuttgart, Germany
1 shared publication Martin Rose
Institute for Energy Technologies, Department of Mechanical and Process Engineering, ETH Zurich, CH-8092, Zurich, Switzerland
1 shared publicationMichael E. Crawford
Siemens Energy, Inc., 4400 Alafaya Trail, Orlando, FL 32826
1 shared publication- Michel Mansour
Laboratory for Energy Conversion, Department of Mechanical and Process Engineering, ETH Zürich, Zürich 8092, Switzerland
1 shared publication
Latest Publications
- Open Access
- 21 June 2017
- Published by Global Power and Propulsion Society
- Vol. 1, 2BIOTO-27
Operational and financial performance of fossil fuel power plants within a high renewable energy mix
The operation of conventional power plants in the 2030 high-renewable energy system of central Europe with high penetration of renewables is simulated in this work. Novel insights are gained in this work, since the generation, transmission and demand models have high geographic resolution, down to scale of individual units, with hourly temporal resolution. It is shown that the increases in the partload efficiency that optimize gas power plants’ financial performance in 2030 are highly dependent on the variability in power production of renewable power plants that are in close proximity to the gas power plants. While coal power plants are also cycled more, an increased baseload efficiency is more beneficial for their financial viability. Thus, there is a need for OEMs to offer a wide range of technology solutions to cover all customers’ needs in electricity markets with high penetrations of renewables. Therefore there is an increased investment risk for OEMs as they strive to match their customers’ future needs.
- 21 June 2017
- Published by Global Power and Propulsion Society
- Vol. 1, 2BIOTO-27
Open AccessOperational and financial performance of fossil fuel power plants within a high renewable energy mix
The operation of conventional power plants in the 2030 high-renewable energy system of central Europe with high penetration of renewables is simulated in this work. Novel insights are gained in this work, since the generation, transmission and demand models have high geographic resolution, down to scale of individual units, with hourly temporal resolution. It is shown that the increases in the partload efficiency that optimize gas power plants’ financial performance in 2030 are highly dependent on the variability in power production of renewable power plants that are in close proximity to the gas power plants. While coal power plants are also cycled more, an increased baseload efficiency is more beneficial for their financial viability. Thus, there is a need for OEMs to offer a wide range of technology solutions to cover all customers’ needs in electricity markets with high penetrations of renewables. Therefore there is an increased investment risk for OEMs as they strive to match their customers’ future needs.
- 28 October 2014
- Published by Wiley in Journal of Turbomachinery
- Vol. 137 (4) , 041005
High Resolution Heat Transfer Measurements on the Stator Endwall of an Axial Turbine
In order to continue increasing the efficiency of gas turbines, an important effort is made on the thermal management of the turbine stage. In particular, understanding and accurately estimating the thermal loads in a vane passage is of primary interest to engine designers looking to optimize the cooling requirements and ensure the integrity of the components. This paper focuses on the measurement of endwall heat transfer in a vane passage with a three-dimensional (3D) airfoil shape and cylindrical endwalls. It also presents a comparison with predictions performed using an in-house developed Reynolds-Averaged Navier–Stokes (RANS) solver featuring a specific treatment of the numerical smoothing using a flow adaptive scheme. The measurements have been performed in a steady state axial turbine facility on a novel platform developed for heat transfer measurements and integrated to the nozzle guide vane (NGV) row of the turbine. A quasi-isothermal boundary condition is used to obtain both the heat transfer coefficient and the adiabatic wall temperature within a single measurement day. The surface temperature is measured using infrared thermography through small view ports. The infrared camera is mounted on a robot arm with six degrees of freedom to provide high resolution surface temperature and a full coverage of the vane passage. The paper presents results from experiments with two different flow conditions obtained by varying the mass flow through the turbine: measurements at the design point (ReCax=7.2×105) and at a reduced mass flow rate (ReCax=5.2×105). The heat transfer quantities, namely the heat transfer coefficient and the adiabatic wall temperature, are derived from measurements at 14 different isothermal temperatures. The experimental data are supplemented with numerical predictions that are deduced from a set of adiabatic and diabatic simulations. In addition, the predicted flow field in the passage is used to highlight the link between the heat transfer patterns measured and the vortical structures present in the passage.
- 28 October 2014
- Published by Wiley in Journal of Turbomachinery
- Vol. 137 (4) , 041005
High Resolution Heat Transfer Measurements on the Stator Endwall of an Axial Turbine
In order to continue increasing the efficiency of gas turbines, an important effort is made on the thermal management of the turbine stage. In particular, understanding and accurately estimating the thermal loads in a vane passage is of primary interest to engine designers looking to optimize the cooling requirements and ensure the integrity of the components. This paper focuses on the measurement of endwall heat transfer in a vane passage with a three-dimensional (3D) airfoil shape and cylindrical endwalls. It also presents a comparison with predictions performed using an in-house developed Reynolds-Averaged Navier–Stokes (RANS) solver featuring a specific treatment of the numerical smoothing using a flow adaptive scheme. The measurements have been performed in a steady state axial turbine facility on a novel platform developed for heat transfer measurements and integrated to the nozzle guide vane (NGV) row of the turbine. A quasi-isothermal boundary condition is used to obtain both the heat transfer coefficient and the adiabatic wall temperature within a single measurement day. The surface temperature is measured using infrared thermography through small view ports. The infrared camera is mounted on a robot arm with six degrees of freedom to provide high resolution surface temperature and a full coverage of the vane passage. The paper presents results from experiments with two different flow conditions obtained by varying the mass flow through the turbine: measurements at the design point (ReCax=7.2×105) and at a reduced mass flow rate (ReCax=5.2×105). The heat transfer quantities, namely the heat transfer coefficient and the adiabatic wall temperature, are derived from measurements at 14 different isothermal temperatures. The experimental data are supplemented with numerical predictions that are deduced from a set of adiabatic and diabatic simulations. In addition, the predicted flow field in the passage is used to highlight the link between the heat transfer patterns measured and the vortical structures present in the passage.
- 2 May 2008
- Published by Wiley in Journal of Turbomachinery
- Vol. 130 (3) , 031005
Experimental Flow Structure Investigation of Compound Angled Film Cooling
The experimental investigation of film-cooling flow structure provides reliable data for calibrating and validating a 3D feature based computational fluid dynamics (CFD) model being developed synchronously at the ETH Zurich. This paper reports on the flow structure of a film-cooling jet emanating from one hole in a row of holes angled 20 deg to the surface of a flat plate having a 45 deg lateral angle to the freestream flow in a steady flow, flat plate wind tunnel. This facility simulates a film-cooling row typically found on a turbine blade, giving engine representative nondimensionals in terms of geometry and operating conditions. The main flow is heated and the injected coolant is cooled strongly to obtain the requisite density ratio. All three velocity components were measured using a nonintrusive stereoscopic particle image velocimetry (PIV) system. The blowing ratio and density ratio are varied for a single compound angled geometry, and the complex three dimensional flow is investigated with special regard to vortical structure.
- 2 May 2008
- Published by Wiley in Journal of Turbomachinery
- Vol. 130 (3) , 031005
Experimental Flow Structure Investigation of Compound Angled Film Cooling
The experimental investigation of film-cooling flow structure provides reliable data for calibrating and validating a 3D feature based computational fluid dynamics (CFD) model being developed synchronously at the ETH Zurich. This paper reports on the flow structure of a film-cooling jet emanating from one hole in a row of holes angled 20 deg to the surface of a flat plate having a 45 deg lateral angle to the freestream flow in a steady flow, flat plate wind tunnel. This facility simulates a film-cooling row typically found on a turbine blade, giving engine representative nondimensionals in terms of geometry and operating conditions. The main flow is heated and the injected coolant is cooled strongly to obtain the requisite density ratio. All three velocity components were measured using a nonintrusive stereoscopic particle image velocimetry (PIV) system. The blowing ratio and density ratio are varied for a single compound angled geometry, and the complex three dimensional flow is investigated with special regard to vortical structure.
- 1 January 2008
- Published by ASME International
- p. 1895-1907
Aerothermal Performance of Streamwise and Compound Angled Pulsating Film Cooling Jets
The quantification of aerothermal loss is carried out for streamwise and compound angled film cooling jets with and without large scale pulsation. This paper reports on the simultaneous measurements of the unsteady pressure and temperature field of streamwise and a 60° compound angled film cooling jet, both with a 30° surface angle over a flat plate with no pressure gradients. Turbine representative non-dimensionals in terms of the geometry and operating conditions are studied. The main flow is heated, more than the injected flow to have a temperature difference and hence a density ratio of 1.3, while the blowing ratio is maintained at 2. The entropy change, derived from pressure and temperature measurements, is calculated by using modified reference conditions to better reflect the losses in both the jet and the freestream. The effects of the periodic unsteadiness associated with rotating machinery are simulated by pulsating the jets. These effects are documented through time-resolved entropy change contours. Mass averaged entropy and kinetic energy loss coefficients seem to be apt quantities for comparing aerothermal performance of streamwise and compound angled injection. It is observed that the mass averaged entropy loss of a streamwise jet doubles when it is pulsated whereas that of a compound angled jet increases by around fifty percent. It may be conjectured from the measurements shown in this study that streamwise oriented jets suffer most of their entropy losses at the hole exit due to separation whereas in compound angled jets, downstream thermal mixing between the jet and the freestream, is the dominant mechanism.
- 1 January 2008
- Published by ASME International
- p. 1895-1907
Aerothermal Performance of Streamwise and Compound Angled Pulsating Film Cooling Jets
The quantification of aerothermal loss is carried out for streamwise and compound angled film cooling jets with and without large scale pulsation. This paper reports on the simultaneous measurements of the unsteady pressure and temperature field of streamwise and a 60° compound angled film cooling jet, both with a 30° surface angle over a flat plate with no pressure gradients. Turbine representative non-dimensionals in terms of the geometry and operating conditions are studied. The main flow is heated, more than the injected flow to have a temperature difference and hence a density ratio of 1.3, while the blowing ratio is maintained at 2. The entropy change, derived from pressure and temperature measurements, is calculated by using modified reference conditions to better reflect the losses in both the jet and the freestream. The effects of the periodic unsteadiness associated with rotating machinery are simulated by pulsating the jets. These effects are documented through time-resolved entropy change contours. Mass averaged entropy and kinetic energy loss coefficients seem to be apt quantities for comparing aerothermal performance of streamwise and compound angled injection. It is observed that the mass averaged entropy loss of a streamwise jet doubles when it is pulsated whereas that of a compound angled jet increases by around fifty percent. It may be conjectured from the measurements shown in this study that streamwise oriented jets suffer most of their entropy losses at the hole exit due to separation whereas in compound angled jets, downstream thermal mixing between the jet and the freestream, is the dominant mechanism.
- 1 January 2006
- Published by ASME International
- Vol. 2006, 127-137
Experimental Validation of Quasi-Steady Assumption in Modelling of Unsteady Film-Cooling
This paper reports on the validation of the assumption of quasi steady behaviour of pulsating cooling injection in the near hole flow region. The respective experimental data are taken in a flat plate wind tunnel at ETH Zu¨rich. The facility simulates the film cooling row flow field on the pressure side of a turbine blade. Engine representative non-dimensionals are achieved, providing a faithful model at larger scale. Heating the free stream air and strongly cooling the coolant gives the required density ratio between coolant and free-stream. The coolant is injected with different frequency and amplitude. The three dimensional velocities are recorded using non-intrusive PIV, seeding is provided for both air streams. Two different cylindrical hole geometries are studied, with different angles. Blowing ratio is varied over a range to simulate pressure side film cooling. The general flow field, the jet trajectory and the streamwise circulation are utilized in the validation of the quasi steady assumption.
- 1 January 2006
- Published by ASME International
- Vol. 2006, 127-137
Experimental Validation of Quasi-Steady Assumption in Modelling of Unsteady Film-Cooling
This paper reports on the validation of the assumption of quasi steady behaviour of pulsating cooling injection in the near hole flow region. The respective experimental data are taken in a flat plate wind tunnel at ETH Zu¨rich. The facility simulates the film cooling row flow field on the pressure side of a turbine blade. Engine representative non-dimensionals are achieved, providing a faithful model at larger scale. Heating the free stream air and strongly cooling the coolant gives the required density ratio between coolant and free-stream. The coolant is injected with different frequency and amplitude. The three dimensional velocities are recorded using non-intrusive PIV, seeding is provided for both air streams. Two different cylindrical hole geometries are studied, with different angles. Blowing ratio is varied over a range to simulate pressure side film cooling. The general flow field, the jet trajectory and the streamwise circulation are utilized in the validation of the quasi steady assumption.