Giorgio Ascenti

Giorgio Ascenti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Giorgio Ascenti has a total of 101 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dual-Layer Spectral CT for Locoregional Assessment of Rectal Cancer: A Comparison with MRI in a Pilot Study

    by Silvio Mazziotti, Giorgio Ascenti, Tommaso D’Angelo, Ludovica R. M. Lanzafame, Pasquale Arena, Alfredo Blandino, Sarah Doria, Simone Barbera, Robert Runinski, Velio Ascenti, et al.

    Background/Objectives: To evaluate the concordance of dual-layer spectral CT (DLSCT) with MRI in locoregional staging of rectal cancer, focusing on 40 keV virtual monoenergetic reconstructions. Methods: This retrospective single-center study included 31 patients (mean age, 69 ± 13.3 years) with rectal cancer who underwent both MRI and DLSCT within 30 days before treatment. Venous-phase CT images were reconstructed at 40 keV. Assessed parameters included tumor location, longitudinal extent, distance from the anorectal junction and anal verge, mesorectal infiltration, circumferential resection margin (CRM) involvement, suspicious lymph nodes, extramural vascular invasion (EMVI), desmoplastic reaction, peritoneal involvement, and anal canal invasion. Two radiologists performed consensus readings. Paired continuous measurements were compared with the Wilcoxon signed-rank test. Agreement for categorical variables was evaluated using Cohen’s kappa; sensitivity, specificity, and accuracy were calculated using MRI as the imaging reference standard. Results: No significant differences were found between MRI and DLSCT for the continuous measurements evaluated. Complete agreement was observed for CRM involvement, anal canal invasion, peritoneal involvement, desmoplastic reaction, and suspicious lymph-node classification (accuracy, 100%; κ = 1.00). Agreement was almost perfect for mesorectal infiltration (κ = 0.84). For EMVI, DLSCT reproduced all MRI-positive classifications but generated two additional positive findings, resulting in 100% sensitivity, 71.4% specificity, 93.5% accuracy, and substantial agreement (κ = 0.79). Conclusions: DLSCT showed high concordance with MRI for several locoregional imaging features of rectal cancer. It may provide complementary information, particularly when MRI is contraindicated or inconclusive. In addition, when DLSCT is performed for systemic staging, it has the potential to provide both locoregional and distant disease assessment within a single examination. However, these findings do not establish equivalence to MRI or diagnostic accuracy against histopathology, and further prospective studies with pathological correlation are warranted.

  • Open Access

    Chatbots in Radiology: Current Applications, Limitations and Future Directions of ChatGPT in Medical Imaging

    by Ludovica R. M. Lanzafame, Claudia Gulli, Silvio Mazziotti, Giorgio Ascenti, Michele Gaeta, Thomas J. Vogl, Ibrahim Yel, Vitali Koch, Leon D. Grünewald, Giuseppe Muscogiuri, et al.

    Artificial intelligence (AI) is reshaping radiological practice, with recent advancements in natural language processing (NLP), large language models (LLMs), and chatbot technologies opening new avenues for clinical integration. These AI-driven conversational agents have demonstrated potential in streamlining patient triage, optimizing imaging protocol selection, supporting image interpretation, automating radiology report generation, and improving communication among radiologists, referring physicians, and patients. Emerging evidence also highlights their role in decision-making, clinical data extraction, and structured reporting. While the clinical adoption of chatbots remains limited by concerns related to data privacy, model robustness, and ethical oversight, ongoing developments and regulatory efforts are paving the way for responsible implementation. This review provides a critical overview of the current and emerging applications of chatbots in radiology, evaluating their capabilities, limitations, and future directions for clinical and research integration.


  • Open Access

    Transcatheter Aortic Valve Implantation (TAVI) Planning with Dual-Layer Spectral CT Using Virtual Monoenergetic Image (VMI) Reconstructions and 20 mL of Contrast Media

    by Federico Fontana, Filippo Piacentino, Aroa Gnesutta, Edoardo Macchi, Andrea Coppola, Angiola Saccomanno, Tonia Gatta, Chiara Recaldini, Manuela Minenna, Claudio Tamborini, et al.

    Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical implantation and its implementation is progressively increasing worldwide. We routinely perform pre-procedural aortic angiography CT to assess aortic dimensions and vascular anatomy. This study aims to evaluate the image quality of CTA for TAVI planning using dual-layer spectral CT, with virtual monoenergetic image reconstructions at 40 keV. Thirty-one patients underwent a CTA protocol with the injection of 20 mL of contrast media. Image quality was assessed by measuring the mean density in Hounsfield Units (HU), the signal-to-noise ratio, and the contrast-to-noise ratio in VMI reconstructions. Additionally, a blinded subjective analysis was conducted by two observers. The results showed significant enhancement at all sampled vascular levels with a gradual decrease in HU from proximal to distal regions. Favourable subjective ratings were given for all parameters, with greater variability in the evaluation of iliac axes. A significant negative correlation (p < 0.05) was observed between BMI and CA at all vascular levels, indicating reduced contrast enhancement with increasing BMI. Spectral CT, along with reducing iodine load, allows for obtaining high-quality images without a significant increase in noise. The reduction in iodine load can have positive implications in clinical practice, improving patient safety and resource efficiency.


  • Open Access

    Therapeutic Management of Children with Vesicoureteral Reflux

    by Valeria Chirico, Filippo Tripodi, Antonio Lacquaniti, Paolo Monardo, Giovanni Conti, Giorgio Ascenti, Roberto Chimenz

    Contrasting data refer to therapies for vesicoureteral reflux (VUR), such as surgical treatments and continuous antibiotic prophylaxis (CAP). This study evaluated the effectiveness of these approaches in children with VUR, analyzing the recurrence of febrile urinary tract infections (UTIs) and the resolution of VUR after the treatment. A total of 350 pediatric patients underwent contrast-enhanced voiding urosonography (ceVUS) to diagnose a VUR, whereas renal scintigraphy evaluated potential scars. After 12 months from the treatment, the VUR, the relapse of febrile UTIs, and reflux-related nephropathy were analyzed. Twenty-seven children had recurrent febrile UTIs after surgical therapy, with a greater rate of relapses observed in III and V VUR grades. Thirteen patients who underwent surgery had scars, independently of VUR grades and gender, with evidence of chronic renal failure at the end of the follow-up period. A total of 140 subjects were treated with CAP, and 30% of them continued to suffer from febrile UTIs. Ninety-five patients with VUR underwent ceVUS after 12 months, with persistent reflux in fifty-two patients. All of them had severe VUR, correlating with the age at diagnosis and gender. CAP therapy prevented scarring better than surgery, especially in children with III and V grades of VUR. A late onset of VUR or VUR involving neonatal patients is rarely a reversible process. This study identified predictors of success or failure of surgical or CAP therapies, evaluating the relapse of UTIs or persistent reflux after the treatment and giving prognostic information in children with VUR.


  • Open Access

    Improved Coronary Artery Visualization Using Virtual Monoenergetic Imaging from Dual-Layer Spectral Detector CT Angiography

    by Tommaso D’angelo, Ludovica R. M. Lanzafame, Antonino Micari, Alfredo Blandino, Ibrahim Yel, Vitali Koch, Leon D. Gruenewald, Thomas J. Vogl, Christian Booz, Giuseppe M. Bucolo, et al.

    Background: To evaluate if coronary CT angiography (CCTA) monoenergetic reconstructions, obtained with a dual-layer spectral detector computed tomography (DLCT) system, offer improved image quality compared with 120 kVp conventional images without affecting the quantitative assessment of coronary stenoses. Methods: Fifty CCTA datasets (30 men; mean age: 61.6 ± 12.3 years) acquired with a DLCT system were reconstructed using virtual monoenergetic images (VMI) from 40 to 100 keV with 10 keV increment and compared with conventional images. An analysis of objective image quality was performed, evaluating the signal- and contrast-to-noise ratio. For the subjective assessment, two readers used a 5-point Likert scoring system to evaluate sharpness, noise, demarcation of coronary plaques, vascular contrast, and an overall score. Furthermore, coronary stenoses were analyzed for each vessel to describe the diagnostic agreement between monoenergetic images and conventional images. Results: The objective image analysis showed that all reconstructions from 70 keV to 40 keV show higher SNR (from 61.33 ± 12.46 to 154.22 ± 42.91, respectively) and CNR (from 51.45 ± 11.19 to 135.63 ± 39.38, respectively) compared with conventional images (all p < 0.001). The 40 keV monoenergetic images obtained the best average score for sharpness, vascular contrast, and for the overall impression (all with p < 0.001). The detection and grading of stenoses of the coronary arteries with conventional and monoenergetic images at 70 keV and 40 keV showed an overall excellent interobserver agreement (k= 0.81 [0.72–0.91]). Conclusions: The 40 keV virtual monoenergetic images obtained with a DLCT system allow the objective and subjective image quality of coronary CT angiography to be improved.


  • Open Access

    Virtual Monoenergetic Imaging of Lower Extremities Using Dual-Energy CT Angiography in Patients with Diabetes Mellitus

    by Giuseppe Mauro Bucolo, Tommaso D’angelo, Ibrahim Yel, Vitali Koch, Leon D. Gruenewald, Ahmed E. Othman, Leona Soraja Alizadeh, Daniel P. Overhoff, Stephan Waldeck, Simon S. Martin, et al.

    Background: Type 2 diabetes mellitus (DM) is the most common metabolic disorder in the world and an important risk factor for peripheral arterial disease (PAD). CT angiography represents the method of choice for the diagnosis, pre-operative planning, and follow-up of vascular disease. Low-energy dual-energy CT (DECT) virtual mono-energetic imaging (VMI) has been shown to improve image contrast, iodine signal, and may also lead to a reduction in contrast medium dose. In recent years, VMI has been improved with the use of a new algorithm called VMI+, able to obtain the best image contrast with the least possible image noise in low-keV reconstructions. Purpose: To evaluate the impact of VMI+ DECT reconstructions on quantitative and qualitative image quality in the evaluation of the lower extremity runoff. Materials and Methods: We evaluated DECT angiography of lower extremities in patients suffering from diabetes who had undergone clinically indicated DECT examinations between January 2018 and January 2023. Images were reconstructed with standard linear blending (F_0.5) and low VMI+ series were generated from 40 to 100 keV, in an interval of 15 keV. Vascular attenuation, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated for objective analysis. Subjective analysis was performed using five-point scales to evaluate image quality, image noise, and diagnostic assessability of vessel contrast. Results: Our final study cohort consisted of 77 patients (41 males). Attenuation values, CNR, and SNR were higher in 40-keV VMI+ reconstructions compared to the remaining VMI+ and standard F_0.5 series (HU: 1180.41 ± 45.09; SNR: 29.91 ± 0.99; CNR: 28.60 ± 1.03 vs. HU 251.32 ± 7.13; SNR: 13.22 ± 0.44; CNR: 10.57 ± 0.39 in standard F_0.5 series) (p < 0.0001). Subjective image rating was significantly higher in 55-keV VMI+ images compared to the other VMI+ and standard F_0.5 series in terms of image quality (mean score: 4.77), image noise (mean score: 4.39), and assessability of vessel contrast (mean value: 4.57) (p < 0.001). Conclusions: DECT 40-keV and 55-keV VMI+ showed the highest objective and subjective parameters of image quality, respectively. These specific energy levels for VMI+ reconstructions could be recommended in clinical practice, providing high-quality images with greater diagnostic suitability for the evaluation of lower extremity runoff, and potentially needing a lower amount of contrast medium, which is particularly advantageous for diabetic patients.


  • Open Access

    Multi-Contrast Differentiation by Dual-Energy Spectral CT Angiography in a Patient with Pulmonary Barium Granulomas

    by Tommaso D’angelo, Francesco M. Arico, Lydia Broccio, Giorgio Ascenti, Silvio Mazziotti, Christian Booz, Simon S. Martin, Ibrahim Yel, Ludovica R. M. Lanzafame, Alfredo Blandino, et al.

    Barium inhalation usually relates to accidental aspiration during radiological procedures with an oral contrast agent. When present, barium lung deposits are visible as high-density opacities on chest X-ray or CT scan due to high atomic number, and they may be indistinguishable from calcifications. Dual-layer spectral CT has shown good material differentiation capabilities, due to its increased high-Z element range and smaller spectral separation between low- and high-energy spectral data. We present the case of a 17-year-old female with a history of tracheoesophageal fistula, who underwent chest CT angiography on a dual-layer spectral platform. Despite the close Z numbers and K-edge energy levels of the two different contrast materials, spectral CT was able to identify barium lung deposits from a previous swallowing study and to clearly distinguish them from calcium and the surrounding iodine-containing structures.


  • Open Access

    Febrile Urinary Tract Infections in Children: The Role of High Mobility Group Box-1

    by Roberto Chimenz, Valeria Chirico, Caterina Cuppari, Alessia Sallemi, Davide Cardile, Sergio Baldari, Giorgio Ascenti, Paolo Monardo, Antonio Lacquaniti

    Background: Differentiating between febrile lower urinary tract infection (LUTI) and acute pyelonephritis (APN) is crucial for prompt clinical management. We investigated whether the high mobility group box-1 (HMGB1) could be a useful biomarker in differentiating between LUTI or APN. Methods: We enrolled seventy-four pediatric patients with suspected LUTI/APN, according to the positive or negative renal scintigraphy (DMSA) scan. If the first DMSA findings were abnormal, a second DMSA was performed after six months. Voiding cystourethrography ruled out vesicoureteral reflux (VUR). Results: Higher serum (s) HMGB1 levels characterized the APN group when compared to LUTI patients (13.3 (11.8–14.3) versus 5.9 (5.2–6.8) ng/mL, p: 0.02), whereas there were no differences according to urine (u) HMGB1 values. sHMGB1 correlated with C-reactive protein (CRP) levels (β = 0.47; p: 0.02). Receiver operating characteristic curves identified the best diagnostic profile for detecting APN. sHMGB1 area under the curve was different from CRP (p: 0.01) and white blood cells (p: 0.003). After multivariate analyses, VUR (HR:4.81) and sHMGB1 (HR 1.16; p: 0.006) were independently associated with the risk of renal scarring development. Conclusions: sHMGB1 could represent a marker to differentiate APN from LUTI. Measurement of sHMGB1 could select children for early intervention or long-term follow-up.


  • MR-Enterography: Technique

    by Silvio Mazziotti, Tommaso D’aNgelo, Giorgio Ascenti, Giuseppe Cicero


  • MR-Enterography beyond Crohn’s Disease

    by Giuseppe Cicero, Tommaso D’aNgelo, Giorgio Ascenti, Silvio Mazziotti