J. F. Kikstra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
J. F. Kikstra has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- A. H. M. Verkooijen
Faculty of Mechanical Engineering, Delft University of Technology, P. O. Box 5073, 2600 AG Delft, The Netherlands
1 shared publication - A. H. M. Verkooijen
Faculty of Mechanical Engineering, Delft University of Technology, P.O. Box 5073, 2600 GA Delft, The Netherlands
1 shared publication
Latest Publications
- 19 June 2002
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 124 (3) , 734-743
Dynamic Modeling of a Cogenerating Nuclear Gas Turbine Plant—Part II: Dynamic Behavior and Control
Using the dynamic model of the cogenerating nuclear gas turbine plant developed in Part I of this article, the dynamic behavior of this plant is analyzed and a control structure is designed. First it is determined how several design choices affect the system dynamics. Then the requirements and options for a control system design are investigated. A number of possible control valve positions in the flowsheet are tested with transients in order to make an argued choice. The model is subsequently used to determine the optimal working conditions for different heat and power demands, these are used as set-points for the control system. Then the interaction between manipulated and controlled variables is mapped and based on this information a choice for coupling them in decentralized feedback control loops is made. This control structure is then tuned and tested. It can be concluded that both heat and power demand can be followed with acceptable performance over a wide range.
- 19 June 2002
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 124 (3) , 734-743
Dynamic Modeling of a Cogenerating Nuclear Gas Turbine Plant—Part II: Dynamic Behavior and Control
Using the dynamic model of the cogenerating nuclear gas turbine plant developed in Part I of this article, the dynamic behavior of this plant is analyzed and a control structure is designed. First it is determined how several design choices affect the system dynamics. Then the requirements and options for a control system design are investigated. A number of possible control valve positions in the flowsheet are tested with transients in order to make an argued choice. The model is subsequently used to determine the optimal working conditions for different heat and power demands, these are used as set-points for the control system. Then the interaction between manipulated and controlled variables is mapped and based on this information a choice for coupling them in decentralized feedback control loops is made. This control structure is then tuned and tested. It can be concluded that both heat and power demand can be followed with acceptable performance over a wide range.
- 19 June 2002
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 124 (3) , 725-733
Dynamic Modeling of a Cogenerating Nuclear Gas Turbine Plant—Part I: Modeling and Validation
The high-temperature gas-cooled reactor is a promising concept for inherently safe nuclear power generation. This article deals with dynamic modeling of a combined heat and power plant, based on a helium-cooled reactor in combination with a closed-cycle gas turbine system. A one-dimensional flow model describing the helium flow and the two-phase water flow is used through the whole plant, with different source terms in different pieces of equipment. A stage-by-stage model is produced for the radial compressor and axial turbine. Other models include the recuperator, water/helium heat exchangers, a natural convection evaporator, valves, etc. In Part II the model will be used to analyze the dynamic behavior and to design a control system.
- 19 June 2002
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 124 (3) , 725-733
Dynamic Modeling of a Cogenerating Nuclear Gas Turbine Plant—Part I: Modeling and Validation
The high-temperature gas-cooled reactor is a promising concept for inherently safe nuclear power generation. This article deals with dynamic modeling of a combined heat and power plant, based on a helium-cooled reactor in combination with a closed-cycle gas turbine system. A one-dimensional flow model describing the helium flow and the two-phase water flow is used through the whole plant, with different source terms in different pieces of equipment. A stage-by-stage model is produced for the radial compressor and axial turbine. Other models include the recuperator, water/helium heat exchangers, a natural convection evaporator, valves, etc. In Part II the model will be used to analyze the dynamic behavior and to design a control system.