Tomoki Nishiyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Tomoki Nishiyama has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
K Hanaoka
28 shared publicationsH Tamai
4 shared publicationsT Yokoyama
Department of Anesthesiology and Resuscitology, Kochi Medical School, Nankoku
4 shared publicationsC Yajima
3 shared publicationsKazuo Hanaoka
3 shared publicationsM Nagase
3 shared publications
Latest Publications
- 1 January 2003
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 96 (1) , 159-162
Serum and Cerebrospinal Fluid Concentrations of Midazolam After Epidural Administration in Dogs
The epidural administration of midazolam has analgesic effects that might be mediated by gamma-aminobutyric acid type A receptors in the spinal cord. In this study, we examined both serum and cerebrospinal fluid (CSF) concentrations of midazolam after epidural administration to investigate the possibility of midazolam entering CSF directly from the epidural space. Five male mongrel dogs had catheters inserted in a femoral artery, the epidural space at L3-4, and the intrathecal space at the atlanto-occipital region under general anesthesia. Midazolam 1 mg/kg was epidurally administered, and arterial blood and CSF samples were collected until 240 min after the midazolam administration to measure midazolam concentration. Serum midazolam concentration increased and reached a peak at 30 min after the administration (224.8 +/- 30.5 ng/mL) and then decreased to 25.8 +/- 6.0 ng/mL at 240 min. Midazolam concentration in the CSF was less than the detection limit at 5 min, reached a peak at 30 min after the administration (7.2 +/- 4.7 ng/mL), and decreased to 3.6 +/- 3.3 ng/mL at 240 min. In conclusion, epidurally administered midazolam enters CSF, but CSF concentrations are only 3% of those in the systemic circulation. Midazolam, which has spinally mediated analgesic potency, was epidurally administered in dogs, and serum and cerebrospinal fluid concentrations were measured. Epidurally administered midazolam enters the cerebrospinal fluid, but concentrations are only 3% of those in the systemic circulation.
- 1 January 2003
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 96 (1) , 159-162
Serum and Cerebrospinal Fluid Concentrations of Midazolam After Epidural Administration in Dogs
The epidural administration of midazolam has analgesic effects that might be mediated by gamma-aminobutyric acid type A receptors in the spinal cord. In this study, we examined both serum and cerebrospinal fluid (CSF) concentrations of midazolam after epidural administration to investigate the possibility of midazolam entering CSF directly from the epidural space. Five male mongrel dogs had catheters inserted in a femoral artery, the epidural space at L3-4, and the intrathecal space at the atlanto-occipital region under general anesthesia. Midazolam 1 mg/kg was epidurally administered, and arterial blood and CSF samples were collected until 240 min after the midazolam administration to measure midazolam concentration. Serum midazolam concentration increased and reached a peak at 30 min after the administration (224.8 +/- 30.5 ng/mL) and then decreased to 25.8 +/- 6.0 ng/mL at 240 min. Midazolam concentration in the CSF was less than the detection limit at 5 min, reached a peak at 30 min after the administration (7.2 +/- 4.7 ng/mL), and decreased to 3.6 +/- 3.3 ng/mL at 240 min. In conclusion, epidurally administered midazolam enters CSF, but CSF concentrations are only 3% of those in the systemic circulation. Midazolam, which has spinally mediated analgesic potency, was epidurally administered in dogs, and serum and cerebrospinal fluid concentrations were measured. Epidurally administered midazolam enters the cerebrospinal fluid, but concentrations are only 3% of those in the systemic circulation.
- 1 December 2001
- Vol. 50 (12) , 1357-9
[Useful tools for prone position: ProneView and OPTI-GARD].
For prone position except for neurosurgery or cervical spinal surgery, head and neck are usually turned sideways on the pillow. This position has a risk of injuries to eyes, nose, lips, ears, or facial nerve and inducing neck pain after surgery. We introduce new tools to avoid these complications from prone position. The ProneView consists of a plastic helmet with a window for eyes, nose and mouth, a sponge to fit the face attached to the helmet, and a mirror to watch eyes, nose and lips. The OPTI-GARD is the glasses made by a sponge with a plastic windows to protect eyes. Using the ProneView and the OPTI-GARD together, patient's neck and head can be kept at neutral position with eyes, nose, lips, and ears being kept free from any pressure. In addition, we can check the position of the face easily by mirror. Therefore, the ProneView and the OPTI-GARD must be useful to decrease injuries to eyes, nose, lips, ears, and facial nerve, and neck pain in prone position.
- 1 December 2001
- Vol. 50 (12) , 1357-9
[Useful tools for prone position: ProneView and OPTI-GARD].
For prone position except for neurosurgery or cervical spinal surgery, head and neck are usually turned sideways on the pillow. This position has a risk of injuries to eyes, nose, lips, ears, or facial nerve and inducing neck pain after surgery. We introduce new tools to avoid these complications from prone position. The ProneView consists of a plastic helmet with a window for eyes, nose and mouth, a sponge to fit the face attached to the helmet, and a mirror to watch eyes, nose and lips. The OPTI-GARD is the glasses made by a sponge with a plastic windows to protect eyes. Using the ProneView and the OPTI-GARD together, patient's neck and head can be kept at neutral position with eyes, nose, lips, and ears being kept free from any pressure. In addition, we can check the position of the face easily by mirror. Therefore, the ProneView and the OPTI-GARD must be useful to decrease injuries to eyes, nose, lips, ears, and facial nerve, and neck pain in prone position.
- 1 November 2001
- Vol. 50 (11) , 1239-41
[Endotracheal intubation with a lighted stylet in a patient with difficult airway from the first and second brancheal arch syndrome].
A 28 year-old-woman with the first and second brancheal arch syndrome was scheduled for the lift of the inferior part of the right ear. Difficult intubation was expected because of the mandibular hypoplasia. We chose a lightwand stylet for tracheal intubation. Anesthesia was induced with sevoflurane slowly increased to 5% in nitrous oxide 3 l.min-1 with oxygen 3 l.min-1. A spiral tube with 6.5 mm inner diameter (Safety-Flex, Mallinckrodt Medical, Ireland) was attached to the lightwand stylet (Surch-Light, Aaron, U.S.A.) and shaped to fit to pharyngo-laryngeal curve. Under spontaneous breathing, the tube was successfully inserted without laryngoscopy. No traumatic events occurred. Usually fiberoptic laryngoscopy requires more skill, more expensive equipment, and more time to prepare than the lightwand stylet technique. Moreover profuse secretions or blood in the oropharynx sometimes inhibit clear vision by fiberoptic laryngoscopy. The lightwand stylet is simple and inexpensive and it is useful for tracheal intubation in patients with difficult airway from the first and second brancheal arch syndrome.
- 1 November 2001
- Vol. 50 (11) , 1239-41
[Endotracheal intubation with a lighted stylet in a patient with difficult airway from the first and second brancheal arch syndrome].
A 28 year-old-woman with the first and second brancheal arch syndrome was scheduled for the lift of the inferior part of the right ear. Difficult intubation was expected because of the mandibular hypoplasia. We chose a lightwand stylet for tracheal intubation. Anesthesia was induced with sevoflurane slowly increased to 5% in nitrous oxide 3 l.min-1 with oxygen 3 l.min-1. A spiral tube with 6.5 mm inner diameter (Safety-Flex, Mallinckrodt Medical, Ireland) was attached to the lightwand stylet (Surch-Light, Aaron, U.S.A.) and shaped to fit to pharyngo-laryngeal curve. Under spontaneous breathing, the tube was successfully inserted without laryngoscopy. No traumatic events occurred. Usually fiberoptic laryngoscopy requires more skill, more expensive equipment, and more time to prepare than the lightwand stylet technique. Moreover profuse secretions or blood in the oropharynx sometimes inhibit clear vision by fiberoptic laryngoscopy. The lightwand stylet is simple and inexpensive and it is useful for tracheal intubation in patients with difficult airway from the first and second brancheal arch syndrome.
- 1 February 2001
- Published by Wolters Kluwer Health
- Vol. 18 (2) , 88-92
Intravenous ketamine attenuates arterial pressure changes during the induction of anaesthesia with propofol
To investigate whether the administration of ketamine before induction with propofol produces a smaller decrease in arterial pressure.Twenty-two patients were assigned to one of two groups to receive either propofol with ketamine (n = 11) or propofol alone (n = 11, control). Anaesthesia was induced with 2 mg kg-1 propofol and 0.5 mg kg-1 ketamine or 2 mg kg-1 propofol alone. Ketamine was administered 1 min prior to induction with propofol. Immediately after induction with propofol, vecuronium (0.15 mg kg-1) was administered. Four minutes after administration of vecuronium, tracheal intubation was performed. Anaesthesia was maintained using sevoflurane (0.5%) in 66% nitrous oxide until 3 min after intubation. Systolic, diastolic and mean arterial pressure and heart rate were recorded on arrival, directly before induction with propofol, prior to tracheal intubation, immediately after intubation and at 3 min after intubation.Administration of ketamine before induction with propofol preserved haemodynamic stability compared with induction with propofol alone.
- 1 February 2001
- Published by Wolters Kluwer Health
- Vol. 18 (2) , 88-92
Intravenous ketamine attenuates arterial pressure changes during the induction of anaesthesia with propofol
To investigate whether the administration of ketamine before induction with propofol produces a smaller decrease in arterial pressure.Twenty-two patients were assigned to one of two groups to receive either propofol with ketamine (n = 11) or propofol alone (n = 11, control). Anaesthesia was induced with 2 mg kg-1 propofol and 0.5 mg kg-1 ketamine or 2 mg kg-1 propofol alone. Ketamine was administered 1 min prior to induction with propofol. Immediately after induction with propofol, vecuronium (0.15 mg kg-1) was administered. Four minutes after administration of vecuronium, tracheal intubation was performed. Anaesthesia was maintained using sevoflurane (0.5%) in 66% nitrous oxide until 3 min after intubation. Systolic, diastolic and mean arterial pressure and heart rate were recorded on arrival, directly before induction with propofol, prior to tracheal intubation, immediately after intubation and at 3 min after intubation.Administration of ketamine before induction with propofol preserved haemodynamic stability compared with induction with propofol alone.
- 1 January 2001
- Vol. 50 (1) , 40-1
[Anesthesia for emergency surgery in a patient with Shy-Drager syndrome].
A 53-year-old man with Shy-Drager syndrome underwent emergency surgery for the resection of the larynx under general anesthesia. Anesthesia was induced with fentanyl 0.1 mg and thiopental 100 mg, and endotracheal intubation was facilitated with vecuronium 8 mg. The onset of action of vecuronium was very slow. Anesthesia was maintained with about 1% of sevoflurane, with nitrous oxide 3 l.min-1 in oxygen 3 l.min-1. Norepinephrine was effective for hypotension while dopamine was not. He was extubated on the first postoperative day without any complications. The effects of vecuronium, norepinephrine, and dopamine might be changed in the patient with Shy-Drager syndrome.
- 1 January 2001
- Vol. 50 (1) , 40-1
[Anesthesia for emergency surgery in a patient with Shy-Drager syndrome].
A 53-year-old man with Shy-Drager syndrome underwent emergency surgery for the resection of the larynx under general anesthesia. Anesthesia was induced with fentanyl 0.1 mg and thiopental 100 mg, and endotracheal intubation was facilitated with vecuronium 8 mg. The onset of action of vecuronium was very slow. Anesthesia was maintained with about 1% of sevoflurane, with nitrous oxide 3 l.min-1 in oxygen 3 l.min-1. Norepinephrine was effective for hypotension while dopamine was not. He was extubated on the first postoperative day without any complications. The effects of vecuronium, norepinephrine, and dopamine might be changed in the patient with Shy-Drager syndrome.
- 1 November 2000
- Vol. 49 (11) , 1267-9
[General anesthesia for a patient on hemodialysis with arteriosclerosis obliterans].
A 48-year-old man with arteriosclerosis obliterans was scheduled for axillofemoral bypass. He had chronic renal failure and on hemodialysis (HD) for 22 years. On the morning of the day of surgery he received HD and two hours later anesthesia was induced with fentanyl 300 micrograms and midazolam 6 mg, and maintained with fentanyl, nitrous oxide and intermittent isoflurane. The common carotid artery was cannulated to measure arterial blood pressure because arteries in extremities were not available. Internal jugular vein at the other side of the arterial catheterization was cannulated to measure central venous pressure. Crystalloid and blood transfusion was performed to adjust hemodynamics and central venous pressure. Hemodynamics were stable during surgery and no complication occurred regarding the common carotid arterial line. The common carotid artery was useful for blood pressure monitoring in a patient whose extremities were not available. Midazolam and fentanyl could give stable hemodynamics to a patient with arteriosclerosis obliterans and chronic renal failure.
- 1 November 2000
- Vol. 49 (11) , 1267-9
[General anesthesia for a patient on hemodialysis with arteriosclerosis obliterans].
A 48-year-old man with arteriosclerosis obliterans was scheduled for axillofemoral bypass. He had chronic renal failure and on hemodialysis (HD) for 22 years. On the morning of the day of surgery he received HD and two hours later anesthesia was induced with fentanyl 300 micrograms and midazolam 6 mg, and maintained with fentanyl, nitrous oxide and intermittent isoflurane. The common carotid artery was cannulated to measure arterial blood pressure because arteries in extremities were not available. Internal jugular vein at the other side of the arterial catheterization was cannulated to measure central venous pressure. Crystalloid and blood transfusion was performed to adjust hemodynamics and central venous pressure. Hemodynamics were stable during surgery and no complication occurred regarding the common carotid arterial line. The common carotid artery was useful for blood pressure monitoring in a patient whose extremities were not available. Midazolam and fentanyl could give stable hemodynamics to a patient with arteriosclerosis obliterans and chronic renal failure.
- 1 November 2000
- Vol. 49 (11) , 1270-3
[Airway obstruction after general anesthesia in a patient with the first and second branchial arch syndrome].
A 20-year-old female with the first and second branchial arch syndrome underwent plastic surgery. Due to her mandibular hypoplasia and trismus, tracheal intubation was difficult even with a broncho-fiberscope. Fentanyl 100 micrograms was used for nasal intubation. Anesthesia was maintained with nitrous oxide (4 l.min-1), oxygen (2 l.min-1) and sevoflurane (0.5-3%). There were no troubles during surgery. The trachea was extubated after recovery of consciousness and spontaneous respiration. Five minutes after extubation, airway was obstructed suddenly after massive nasal bleeding. Sudden massive bleeding might have caused airway obstruction. Emergency insertion of an 18 G needle followed by Mini-trach II into the trachea through the cryothyroidal ligament improved her respiratory condition. The case suggests that preparing the instrument for the emergency cryothyroidal ligament puncture (for instance Mini-trach II) is useful for a patient with a risk of bleeding in the airway and with difficult intubation.
- 1 November 2000
- Vol. 49 (11) , 1270-3
[Airway obstruction after general anesthesia in a patient with the first and second branchial arch syndrome].
A 20-year-old female with the first and second branchial arch syndrome underwent plastic surgery. Due to her mandibular hypoplasia and trismus, tracheal intubation was difficult even with a broncho-fiberscope. Fentanyl 100 micrograms was used for nasal intubation. Anesthesia was maintained with nitrous oxide (4 l.min-1), oxygen (2 l.min-1) and sevoflurane (0.5-3%). There were no troubles during surgery. The trachea was extubated after recovery of consciousness and spontaneous respiration. Five minutes after extubation, airway was obstructed suddenly after massive nasal bleeding. Sudden massive bleeding might have caused airway obstruction. Emergency insertion of an 18 G needle followed by Mini-trach II into the trachea through the cryothyroidal ligament improved her respiratory condition. The case suggests that preparing the instrument for the emergency cryothyroidal ligament puncture (for instance Mini-trach II) is useful for a patient with a risk of bleeding in the airway and with difficult intubation.
- 1 September 2000
- Vol. 49 (9) , 1030-2
[Anesthesia for a cervical myelopathy patient with tracheal stenosis].
A 71-year-old male with cervical myelopathy was scheduled for C 3-7 laminectomy. Once he had been rejected of general anesthesia in other hospital because of his tracheal stenosis. The diameter of the narrowest part of his trachea was 5 mm probably resulting from tracheostomy at 2 years of age. His cervical myelopathy seemed to be no problem for anesthesia induction because he had no problems in his neck movement and opening mouth. We evaluated his tracheal stenosis carefully using bronchofiberscopy, chest X-ray, computed tomography and pulmonary function tests. After intravenous fentanyl 100 micrograms and midazolam 2.5 mg, it was impossible to ventilate the patient. Therefore, tracheal intubation was performed immediately after lidocaine administration into the trachea. During surgery, tracheal tube dilated the narrowed portion. After surgery, the tracheal tube was removed under bronchofiberscopic observation without any problems. Tracheal stenosis was observed by chest X-ray after surgery, but he had no complaints.
- 1 September 2000
- Vol. 49 (9) , 1030-2
[Anesthesia for a cervical myelopathy patient with tracheal stenosis].
A 71-year-old male with cervical myelopathy was scheduled for C 3-7 laminectomy. Once he had been rejected of general anesthesia in other hospital because of his tracheal stenosis. The diameter of the narrowest part of his trachea was 5 mm probably resulting from tracheostomy at 2 years of age. His cervical myelopathy seemed to be no problem for anesthesia induction because he had no problems in his neck movement and opening mouth. We evaluated his tracheal stenosis carefully using bronchofiberscopy, chest X-ray, computed tomography and pulmonary function tests. After intravenous fentanyl 100 micrograms and midazolam 2.5 mg, it was impossible to ventilate the patient. Therefore, tracheal intubation was performed immediately after lidocaine administration into the trachea. During surgery, tracheal tube dilated the narrowed portion. After surgery, the tracheal tube was removed under bronchofiberscopic observation without any problems. Tracheal stenosis was observed by chest X-ray after surgery, but he had no complaints.
- 1 September 2000
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 91 (3) , 652-656
The Effects of Epidural Bupivacaine, Morphine, and Their Combination on Thermal Nociception with Different Stimulus Intensity in Rats
The analgesic effect of drugs depends on the stimulus intensity as well as the potency of the drugs. We investigated the effects of stimulus intensity on antinociceptive potencies of epidural bupivacaine + morphine. Sprague-Dawley rats implanted with chronic lumbar epidural catheters were tested for paw withdrawal response to thermal stimulation after the epidural injection of bupivacaine, morphine, or bupivacaine + morphine. Two stimulation currents were used, 5.1 and 4.6 A, to provide baseline response latency of approximately 5.0 s (high intensity) and 10.0 s (low intensity), respectively. Increasing the dose of epidural morphine in a dose range that had a maximum effect on low-intensity stimulation was not effective for high-intensity stimulation. Bupivacaine, which alone had no effect, potentiated the antinociceptive effect of epidural morphine at both high- and low-intensity stimuli similarly. We concluded that bupivacaine potentiated the analgesic effect of epidural morphine at both weak and strong nociceptive stimuli similarly, whereas increasing the dose of epidural morphine was not as effective for strong nociceptive stimulation. Therefore, adding bupivacaine might be more effective than increasing the dose of epidural morphine for intense nociception. When patients have severe pain even when receiving epidural morphine, adding bupivacaine might be more effective than increasing the dose of epidural morphine.
- 1 September 2000
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 91 (3) , 652-656
The Effects of Epidural Bupivacaine, Morphine, and Their Combination on Thermal Nociception with Different Stimulus Intensity in Rats
The analgesic effect of drugs depends on the stimulus intensity as well as the potency of the drugs. We investigated the effects of stimulus intensity on antinociceptive potencies of epidural bupivacaine + morphine. Sprague-Dawley rats implanted with chronic lumbar epidural catheters were tested for paw withdrawal response to thermal stimulation after the epidural injection of bupivacaine, morphine, or bupivacaine + morphine. Two stimulation currents were used, 5.1 and 4.6 A, to provide baseline response latency of approximately 5.0 s (high intensity) and 10.0 s (low intensity), respectively. Increasing the dose of epidural morphine in a dose range that had a maximum effect on low-intensity stimulation was not effective for high-intensity stimulation. Bupivacaine, which alone had no effect, potentiated the antinociceptive effect of epidural morphine at both high- and low-intensity stimuli similarly. We concluded that bupivacaine potentiated the analgesic effect of epidural morphine at both weak and strong nociceptive stimuli similarly, whereas increasing the dose of epidural morphine was not as effective for strong nociceptive stimulation. Therefore, adding bupivacaine might be more effective than increasing the dose of epidural morphine for intense nociception. When patients have severe pain even when receiving epidural morphine, adding bupivacaine might be more effective than increasing the dose of epidural morphine.
- 1 August 2000
- Vol. 49 (8) , 881-3
[Hoarseness after endotracheal intubation caused by submucosal hemorrage of the vocal cord and recurrent nerve palsy].
Hoarseness often follows endotracheal intubation. A 58 year old man suffered from hoarseness due to recurrent nerve palsy and submucosal hemorrhage of the right vocal cord after general anesthesia. He was scheduled for resection of chronic pyoderma of the buttocks and atheroma of the right retroauricular region. Anesthesia was induced with thiopental 300 mg and endotracheal intubation was facilitated with vecuronium 6 mg. A spiral tube with 8 mm of inner diameter (Mallinckrodt Medical) was inserted with no problems. The tube was fixed at left side of the mouth. The cuff was inflated with air but the cuff pressure was not monitored. Anesthesia was maintained with sevoflurane (1-3%) and 67% N2O in 33% O2. Respiration was controlled mechanically. The patient was turned to the prone position and his head was turned to the right. The duration of surgery was one hour and forty minutes. Extubation of the tube involved no problems. He complained of hoarseness after surgery. Right recurrent nerve palsy and submucosal hematoma were observed. Without any treatment, hematoma disappeared in 70 days and hoarseness in 183 days. These hematoma and recurrent nerve palsy might be due to the compression of the vocal cord and recurrent nerve by tracheal tube and traction of the recurrent nerve by rotation of the neck.
- 1 August 2000
- Vol. 49 (8) , 881-3
[Hoarseness after endotracheal intubation caused by submucosal hemorrage of the vocal cord and recurrent nerve palsy].
Hoarseness often follows endotracheal intubation. A 58 year old man suffered from hoarseness due to recurrent nerve palsy and submucosal hemorrhage of the right vocal cord after general anesthesia. He was scheduled for resection of chronic pyoderma of the buttocks and atheroma of the right retroauricular region. Anesthesia was induced with thiopental 300 mg and endotracheal intubation was facilitated with vecuronium 6 mg. A spiral tube with 8 mm of inner diameter (Mallinckrodt Medical) was inserted with no problems. The tube was fixed at left side of the mouth. The cuff was inflated with air but the cuff pressure was not monitored. Anesthesia was maintained with sevoflurane (1-3%) and 67% N2O in 33% O2. Respiration was controlled mechanically. The patient was turned to the prone position and his head was turned to the right. The duration of surgery was one hour and forty minutes. Extubation of the tube involved no problems. He complained of hoarseness after surgery. Right recurrent nerve palsy and submucosal hematoma were observed. Without any treatment, hematoma disappeared in 70 days and hoarseness in 183 days. These hematoma and recurrent nerve palsy might be due to the compression of the vocal cord and recurrent nerve by tracheal tube and traction of the recurrent nerve by rotation of the neck.