Nobuko Sasano
Nobuko Sasano has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Hiroshi Sasano
Nagoya City University Graduate School of Medical Sciences
2 shared publicationsYoshihito Fujita
Nagoya City University Graduate School of Medical Sciences
2 shared publicationsAi Muramatsu
Nagoya City University Graduate School of Medical Sciences
1 shared publicationAkemi Tanaka
Nagoya City West Medical Center
1 shared publicationHiroe Takasu
Nagoya Daini Red Cross Hospital
1 shared publicationHiroki Yamauchi
Graduate School of Medical Sciences
1 shared publication
Latest Publications
- 9 November 2013
- Published by Springer Nature in Journal of Anesthesia
- Vol. 28 (3) , 341-346
Tidal volume and airway pressure under percutaneous transtracheal ventilation without a jet ventilator: comparison of high-flow oxygen ventilation and manual ventilation in complete and incomplete upper airway obstruction models
Percutaneous transtracheal ventilation (PTV) can be life-saving in a cannot ventilate, cannot intubate situation. The aim of this study was to investigate the efficacy of PTV by measuring tidal volumes (VTs) and airway pressure (Paw) in high-flow oxygen ventilation and manual ventilation using a model lung. We examined 14G, 16G, 18G, and 20G intravenous catheters and minitracheotomy catheters. In high-flow oxygen ventilation, the flow was set to 10 L/min, while the inspiratory:expiratory phases (I:E) were 1 s:4 s in the complete upper airway obstruction model and 1 s:1 s in the incomplete obstruction model. In manual ventilation, I:E were 2 s:4 s in the complete obstruction model and 2 s:3 s in the incomplete obstruction model. We ventilated through each catheter for 2 min and measured VT and Paw. In high-flow ventilation, the average VTs were approximately 150 ml and <100 ml with 14G catheters in complete and incomplete upper airway obstruction, respectively. The VTs obtained were reduced when the bore size was decreased. In manual ventilation, the average VTs were over 300 ml and approximately 260 ml with 14G catheters in complete and incomplete upper airway obstruction, respectively. In high-flow ventilation, the airway pressure tended to be higher. The minitracheotomy catheters produced over 800 ml of VT and created almost no positive end-expiratory pressure. High-flow ventilation tends to result in higher airway pressure despite a smaller VT, which is probably due to a PEEP effect caused by high flow.
- 9 November 2013
- Published by Springer Nature in Journal of Anesthesia
- Vol. 28 (3) , 341-346
Tidal volume and airway pressure under percutaneous transtracheal ventilation without a jet ventilator: comparison of high-flow oxygen ventilation and manual ventilation in complete and incomplete upper airway obstruction models
Percutaneous transtracheal ventilation (PTV) can be life-saving in a cannot ventilate, cannot intubate situation. The aim of this study was to investigate the efficacy of PTV by measuring tidal volumes (VTs) and airway pressure (Paw) in high-flow oxygen ventilation and manual ventilation using a model lung. We examined 14G, 16G, 18G, and 20G intravenous catheters and minitracheotomy catheters. In high-flow oxygen ventilation, the flow was set to 10 L/min, while the inspiratory:expiratory phases (I:E) were 1 s:4 s in the complete upper airway obstruction model and 1 s:1 s in the incomplete obstruction model. In manual ventilation, I:E were 2 s:4 s in the complete obstruction model and 2 s:3 s in the incomplete obstruction model. We ventilated through each catheter for 2 min and measured VT and Paw. In high-flow ventilation, the average VTs were approximately 150 ml and <100 ml with 14G catheters in complete and incomplete upper airway obstruction, respectively. The VTs obtained were reduced when the bore size was decreased. In manual ventilation, the average VTs were over 300 ml and approximately 260 ml with 14G catheters in complete and incomplete upper airway obstruction, respectively. In high-flow ventilation, the airway pressure tended to be higher. The minitracheotomy catheters produced over 800 ml of VT and created almost no positive end-expiratory pressure. High-flow ventilation tends to result in higher airway pressure despite a smaller VT, which is probably due to a PEEP effect caused by high flow.
- 1 September 2007
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 54 (9) , 774-775
Failure of the Airway Scope to reach the larynx
- 1 September 2007
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 54 (9) , 774-775
Failure of the Airway Scope to reach the larynx
- 1 November 2004
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 51 (9) , 875-879
Cerebral fat embolism diagnosed by magnetic resonance imaging at one, eight, and 50 days after hip arthroplasty: a case report
To describe cardiovascular collapse during a cemented hip hemiarthroplasty in a patient who, despite a successful cardiopulmonary resuscitation, remained in a persistent vegetative state due to cerebral fat embolism diagnosed by magnetic resonance imaging (MRI).
- 1 November 2004
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 51 (9) , 875-879
Cerebral fat embolism diagnosed by magnetic resonance imaging at one, eight, and 50 days after hip arthroplasty: a case report
To describe cardiovascular collapse during a cemented hip hemiarthroplasty in a patient who, despite a successful cardiopulmonary resuscitation, remained in a persistent vegetative state due to cerebral fat embolism diagnosed by magnetic resonance imaging (MRI).