Ponciano Rodriguez-Montero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ponciano Rodriguez-Montero has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
A. De-Roa-Campoy
Facultad de Ciencias de la Electrónica, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
1 shared publicationB. Rodríguez-Pedroza
Instituto Nacional de Astrofisica, Optica y Electronica, Puebla, Mexico
1 shared publicationB. Sanchez
National Institute for Astrophysics, Optics and Electronics (Mexico)
1 shared publicationC. M. Gómez-Sarabia
University of Guanajuato
1 shared publicationE. Valadez-Campos
Facultad de Ciencias de la Electrónica, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
1 shared publicationI. C. Medina-Carrillo
Universidad Autónoma de Nayarit, Nayarit, México
1 shared publication
Latest Publications
- 20 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Instrumentation & Measurement Magazine
- Vol. 24 (5) , 20-27
Non-Contact Liquid Level Measurement Using Optical Interferometry and Neural Networks
Measurement of liquid levels inside containers is an important task in a number of industrial and scientific processes. In applications such as fuel monitoring, pharmaceutical industries, wastewater treatment, and food processes, the knowledge of the liquid level is of primary concern. Furthermore, the advent of new technologies and a growing number of applications require exploration of new sensors and techniques aiming at content level measurement. Over the years, several methods have been proposed to achieve this objective with pros and cons according to the specific area. At first glance, those methods can be grouped in mechanical [1], capacitive [2], [3], electromagnetic [4], [5], acoustic [6], ultrasonic [7], optical fiber sensors [8], or self-mixing interferometry [9], among others. A relevant condition of these techniques is whether they are invasive or not; for instance, transducers or sensors attached to the container or even immersed in the liquid can be unacceptable in certain applications in the pharmaceutical or food processing industries. A brief description of the principle of operation of each technique is as follows.
- 20 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Instrumentation & Measurement Magazine
- Vol. 24 (5) , 20-27
Non-Contact Liquid Level Measurement Using Optical Interferometry and Neural Networks
Measurement of liquid levels inside containers is an important task in a number of industrial and scientific processes. In applications such as fuel monitoring, pharmaceutical industries, wastewater treatment, and food processes, the knowledge of the liquid level is of primary concern. Furthermore, the advent of new technologies and a growing number of applications require exploration of new sensors and techniques aiming at content level measurement. Over the years, several methods have been proposed to achieve this objective with pros and cons according to the specific area. At first glance, those methods can be grouped in mechanical [1], capacitive [2], [3], electromagnetic [4], [5], acoustic [6], ultrasonic [7], optical fiber sensors [8], or self-mixing interferometry [9], among others. A relevant condition of these techniques is whether they are invasive or not; for instance, transducers or sensors attached to the container or even immersed in the liquid can be unacceptable in certain applications in the pharmaceutical or food processing industries. A brief description of the principle of operation of each technique is as follows.
- 31 March 2019
- Published by Universidad Nacional Autonoma de Mexico in Revista Mexicana de Astronomía y Astrofísica
- Vol. 55 (1) , 11-16
A SOLAR MID-INFRARED TELESCOPE
We developed a mid infrared (MIR) solar telescope, centered at 10 µm. Various optical layouts were analyzed based on computer simulations and a RitcheyChretien 6-inches telescope was selected with a plate scale of 2.5′′/mm using a pyroelectric 4 × 16 pixels detector. The angular resolution is 36′′/pixel with a field of view of 9.6′×2.4′. Two germanium filters are used, one at the aperture of thetelescope and another near its focal plane. The detector was characterized with alaboratory black-body. The count values follow a linear relation with the blackbody temperature. The control systems for both the telescope and the detectorwere developed. Proper mechanical supports were designed for the filters, detectorand electronics. The system has been integrated and a user interface was developed. Preliminary observations have been made giving a signal-to-noise ratio of ≈ 1000.
- 31 March 2019
- Published by Universidad Nacional Autonoma de Mexico in Revista Mexicana de Astronomía y Astrofísica
- Vol. 55 (1) , 11-16
A SOLAR MID-INFRARED TELESCOPE
We developed a mid infrared (MIR) solar telescope, centered at 10 µm. Various optical layouts were analyzed based on computer simulations and a RitcheyChretien 6-inches telescope was selected with a plate scale of 2.5′′/mm using a pyroelectric 4 × 16 pixels detector. The angular resolution is 36′′/pixel with a field of view of 9.6′×2.4′. Two germanium filters are used, one at the aperture of thetelescope and another near its focal plane. The detector was characterized with alaboratory black-body. The count values follow a linear relation with the blackbody temperature. The control systems for both the telescope and the detectorwere developed. Proper mechanical supports were designed for the filters, detectorand electronics. The system has been integrated and a user interface was developed. Preliminary observations have been made giving a signal-to-noise ratio of ≈ 1000.
- 27 February 2013
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 30 (3) , 730-735
Non-steady-state photoelectromotive force induced by a vibrating Ronchi grating: manifestation of a fractal structure
We demonstrate that the non-steady-state photoelectromotive force induced by a vibrating Ronchi grating has a very complicated but deterministic dependence on the propagation distance. The characteristic minima of this dependence are found at fractional values of the Talbot distance, and their width is determined by the maximal transversal spatial frequency resolved by the system. This permits high accuracy in the determination of the Talbot distance.
- 27 February 2013
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 30 (3) , 730-735
Non-steady-state photoelectromotive force induced by a vibrating Ronchi grating: manifestation of a fractal structure
We demonstrate that the non-steady-state photoelectromotive force induced by a vibrating Ronchi grating has a very complicated but deterministic dependence on the propagation distance. The characteristic minima of this dependence are found at fractional values of the Talbot distance, and their width is determined by the maximal transversal spatial frequency resolved by the system. This permits high accuracy in the determination of the Talbot distance.
- 11 July 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 47 (21) , 3778-3783
Adaptive photodetector for assisted Talbot effect
We use an adaptive photodetector for measuring the visibility of the Fresnel diffraction patterns generated by a grating. Visibility is measured in real time, with high spatial resolution, and without any signal processing. This method is well suited for analyzing the Talbot effect and its many applications.
- 11 July 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 47 (21) , 3778-3783
Adaptive photodetector for assisted Talbot effect
We use an adaptive photodetector for measuring the visibility of the Fresnel diffraction patterns generated by a grating. Visibility is measured in real time, with high spatial resolution, and without any signal processing. This method is well suited for analyzing the Talbot effect and its many applications.
- 4 October 1994
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2264, 178-187
High-sensitivity adaptive vibration measurements with nonsteady-state photo-EMF-based photodetectors
We present results of detailed experimental study of threshold sensitivity of GaAs adaptive photodetector at 632.8 nm. The minimal experimentally detected sinusoidal phase modulation was approximately equals 1.6 X 10-6 rad(root)mW/Hz that approached the theoretical limit for these devices (approximately equals 2 X 10-7 rad(root)mW/Hz) and allowed detection of approximately equals 1.6 X 10-7 micrometers vibration amplitudes with 1 mW laser power in 1 Hz bandwidth.
- 4 October 1994
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2264, 178-187
High-sensitivity adaptive vibration measurements with nonsteady-state photo-EMF-based photodetectors
We present results of detailed experimental study of threshold sensitivity of GaAs adaptive photodetector at 632.8 nm. The minimal experimentally detected sinusoidal phase modulation was approximately equals 1.6 X 10-6 rad(root)mW/Hz that approached the theoretical limit for these devices (approximately equals 2 X 10-7 rad(root)mW/Hz) and allowed detection of approximately equals 1.6 X 10-7 micrometers vibration amplitudes with 1 mW laser power in 1 Hz bandwidth.