Peter Kneschaurek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Peter Kneschaurek has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
S Stärk
2 shared publicationsA L Grosu
Klinik und Poliklinik für Strahlentherapie und Radiologische Onkologie, Klinikum rechts der Isar der Technischen Universität München
1 shared publicationA.L. Grosu
1 shared publicationAnca -Ligia Grosu
Klinik und Poliklinik für Strahlentherapie und Radiologische Onkologie der Technischen Universität München
1 shared publicationC Lumenta
1 shared publication- Carsten Nieder
Institute of Clinical Medicine, Faculty of Health Sciences, UiT – The Arctic University of Norway, Tromsø, Norway
1 shared publication
Latest Publications
- 29 September 2012
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 188 (3) , 245-252
Entwicklung von Bestrahlungsmethoden und Geräten
- 29 September 2012
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 188 (3) , 245-252
Entwicklung von Bestrahlungsmethoden und Geräten
- Open Access
- 1 December 2007
- Published by Springer Nature in Radiation Oncology
- Vol. 2 (1) , 1-7
Influence of different treatment techniques on radiation dose to the LAD coronary artery
Background: The purpose of this proof-of-principle study was to test the ability of an intensity-modulated radiotherapy (IMRT) technique to reduce the radiation dose to the heart plus the left ventricle and a coronary artery. Radiation-induced heart disease might be a serious complication in long-term cancer survivors. Methods: Planning CT scans from 6 female patients were available. They were part of a previous study of mediastinal IMRT for target volumes used in lymphoma treatment that included 8 patients and represent all cases where the left anterior descending coronary artery (LAD) could be contoured. We compared 6 MV AP/PA opposed fields to a 3D conformal 4-field technique and an optimised 7-field step-and-shoot IMRT technique and evaluated DVH's for several structures. The planning system was BrainSCAN 5.21 (BrainLAB, Heimstetten, Germany). Results: IMRT maintained target volume coverage but resulted in better dose reduction to the heart, left ventricle and LAD than the other techniques. Selective dose reduction could be accomplished, although not to the degree initially attempted. The median LAD dose was approximately 50% lower with IMRT. In 5 out of 6 patients, IMRT was the best technique with regard to heart sparing. Conclusion: IMRT techniques are able to reduce the radiation dose to the heart. In addition to dose reduction to whole heart, individualised dose distributions can be created, which spare, e.g., one ventricle plus one of the coronary arteries. Certain patients with well-defined vessel pathology might profit from an approach of general heart sparing with further selective dose reduction, accounting for the individual aspects of pre-existing damage.
- 1 December 2007
- Published by Springer Nature in Radiation Oncology
- Vol. 2 (1) , 1-7
Open AccessInfluence of different treatment techniques on radiation dose to the LAD coronary artery
Background: The purpose of this proof-of-principle study was to test the ability of an intensity-modulated radiotherapy (IMRT) technique to reduce the radiation dose to the heart plus the left ventricle and a coronary artery. Radiation-induced heart disease might be a serious complication in long-term cancer survivors. Methods: Planning CT scans from 6 female patients were available. They were part of a previous study of mediastinal IMRT for target volumes used in lymphoma treatment that included 8 patients and represent all cases where the left anterior descending coronary artery (LAD) could be contoured. We compared 6 MV AP/PA opposed fields to a 3D conformal 4-field technique and an optimised 7-field step-and-shoot IMRT technique and evaluated DVH's for several structures. The planning system was BrainSCAN 5.21 (BrainLAB, Heimstetten, Germany). Results: IMRT maintained target volume coverage but resulted in better dose reduction to the heart, left ventricle and LAD than the other techniques. Selective dose reduction could be accomplished, although not to the degree initially attempted. The median LAD dose was approximately 50% lower with IMRT. In 5 out of 6 patients, IMRT was the best technique with regard to heart sparing. Conclusion: IMRT techniques are able to reduce the radiation dose to the heart. In addition to dose reduction to whole heart, individualised dose distributions can be created, which spare, e.g., one ventricle plus one of the coronary arteries. Certain patients with well-defined vessel pathology might profit from an approach of general heart sparing with further selective dose reduction, accounting for the individual aspects of pre-existing damage.
- 1 October 1999
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 45 (3) , 811-815
Volume-based dose optimization in brachytherapy
- 1 October 1999
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 45 (3) , 811-815
Volume-based dose optimization in brachytherapy
- 1 June 1999
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 175 (2) , 8-9
Treatment planning for conformal stereotactic radiotherapy.
- 1 June 1999
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 175 (2) , 8-9
Treatment planning for conformal stereotactic radiotherapy.
- 1 May 1999
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 175 (5) , 197-207
Inverse bestrahlungsplanung
In der klinischen Praxis gibt es immer wieder Fälle, bei denen mit konventionellen Methoden keine zufriedenstellende Dosisverteilung erzielt werden kann. Für diese Fälle können die inverse Bestrahlungsplanung und eine Strahlentherapie mit intensitätsmodulierten Feldern möglicherweise eine Lösung bieten.
- 1 May 1999
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 175 (5) , 197-207
Inverse bestrahlungsplanung
In der klinischen Praxis gibt es immer wieder Fälle, bei denen mit konventionellen Methoden keine zufriedenstellende Dosisverteilung erzielt werden kann. Für diese Fälle können die inverse Bestrahlungsplanung und eine Strahlentherapie mit intensitätsmodulierten Feldern möglicherweise eine Lösung bieten.
- 1 September 1998
- Vol. 174 (9)
[Remarks on the dosage problem in HDR brachytherapy].
- 1 September 1998
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 174 (9) , 468-472
Anmerkungen zum Problem der Dosierung in der HDR-Brachytherapie
In der High-dose-rate (HDR-)Brachytherapie sind Aktivitätsverteilungen möglich, wie sie in der Lowdose-rate-(LDR-)Brachytherapie sind Aktivitätsverteilungen möglich, wie sie in der Lowdose-rate-(LDR-) Brachtytherapie nicht bekannt waren. Aus diesem Grunde müssen für die HDR-Brachytherapie geänderte Dosierungskonzepte entwickelt werden.
- 1 September 1998
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 174 (9) , 468-472
Anmerkungen zum Problem der Dosierung in der HDR-Brachytherapie
In der High-dose-rate (HDR-)Brachytherapie sind Aktivitätsverteilungen möglich, wie sie in der Lowdose-rate-(LDR-)Brachytherapie sind Aktivitätsverteilungen möglich, wie sie in der Lowdose-rate-(LDR-) Brachtytherapie nicht bekannt waren. Aus diesem Grunde müssen für die HDR-Brachytherapie geänderte Dosierungskonzepte entwickelt werden.
- 30 September 1997
- Published by Elsevier in European Journal of Cancer
- Vol. 33, S204
921: Stereotactic external beam radiotherapy of brain metastases — Clinical results of a prospective study
- 30 September 1997
- Published by Elsevier in European Journal of Cancer
- Vol. 33, S204
921: Stereotactic external beam radiotherapy of brain metastases — Clinical results of a prospective study