ASA. Nicolaas Schreuder

A. Nicolaas Schreuder

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


A. Nicolaas Schreuder has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The NAC proton treatment planning system

    by Andries N. Schreuder, Dan T. L. Jones, Julyan E. Symons, Evan A. De Kock, Jan K. Hough, Jenny Wilson, Fred J. A. Vernimmen, Wolfgang Schlegel, Angelika Höss, Michael Lee

    A three-dimensional proton treatment planning system called PROXELPLAN has been used at the National Accelerator Centre (NAC) since October 1994. This system is entirely based on the VOXELPLAN planning system, developed at the Deutches Krebsforschungszentrum (DKFZ), Heidelberg, Germany. The VOXELPLAN system provides the treatment planning infrastructure while the proton dose distributions are calculated using a software module that was initially developed at the Royal Marsden Hospital, UK. The proton module has been extensively modified and refined. It uses a rayline-tracing algorithm which is suitable for planning current treatments but is not sufficiently dynamic to accommodate the use of compensators. A sophisticated pencil beam algorithm is currently under development.


  • Status report of the NAC particle therapy programme

    by Dan T. L. Jones, A. Nicolaas Schreuder, Julyan E. Symons, Evan A. de Kock, Frederick J. A. Vernimmen, Clare E. Stannard, Jennifer Wilson, Gerd Schmitt

    Summary The 200 MeV cyclotron facility at the National Accelerator Centre has been operational since 1987. Between September 1988 and December 1997 a total of 973 patients (26,916 fields) had been treated on the 66 MeV p+Be isocentric neutron therapy system. Patients are currently being treated according to several protocols, including tumors of the head and neck, salivary gland and breast and soft tissue sarcomas, uterine sarcomas and paranasal sinuses. A multiblade post-collimator trimmer has recently being installed. This device procides improved neutron beam shaping capability. Between September 1993 and December 1997 a total of 243 patients (4008 fields) had been treated (mainly intracranial stereotactic irradiations) on the fixed horizontal 200 MeV proton therapy facility. The facility incorporates an innovative automatic patient positioning system. Two new fixed beam lines for proton therapy are presently being designed (horizontal and 30° to the vertical) for an existing unused treatment vault. Spot scanning systems will be developed for both beam lines.


    • 1 August 1996
      • Vol. 41  (8) , 1524-7

    Comments on 'The calibration of CT Hounsfield units for radiotherapy treatment planning'.

    by E A De Kock, A N Schreuder