PKPatricia L. Kleinman

Patricia L. Kleinman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Patricia L. Kleinman has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Pediatric CT Dose Reduction for Suspected Appendicitis: A Practice Quality Improvement Project Using Artificial Gaussian Noise—Part 1, Computer Simulations

    by Michael J. Callahan, Patricia L. Kleinman, Keith J. Strauss, Andriy Bandos, George A. Taylor, Andy Tsai, Paul K. Kleinman

    The purpose of this study was to develop a departmental practice quality improvement project to systematically reduce CT doses for the evaluation of suspected pediatric appendicitis by introducing computer-generated gaussian noise.Two hundred MDCT abdominopelvic examinations of patients younger than 20 years performed with girth-based scanning parameters for suspected appendicitis were reviewed. Two judges selected 45 examinations in which the diagnosis of appendicitis was excluded (14, appendix not visualized; 31, normal appendix visualized). Gaussian noise was introduced into axial image series, creating five additional series acquired at 25-76% of the original dose. Two readers reviewed 270 image series for appendix visualization (4-point Likert scale and arrow localization). Volume CT dose index (CTDIvol) and size-specific dose estimate (SSDE) were calculated by use of patient girth. Confidence ratings and localization accuracy were analyzed with mixed models and nonparametric bootstrap analysis at a 0.05 significance level.The mean baseline SSDE for the 45 patients was 16 mGy (95% CI, 12-20 mGy), and the corresponding CTDIvol was 10 mGy (95% CI, 4-16 mGy). Changes in correct appendix localization frequencies were minor. There was no substantial trend with decreasing simulated dose level (p = 0.46). Confidence ratings decreased with increasing dose reduction (p = 0.007). The average decreases were -0.27 for the 25% simulated dose (p = 0.01), -0.17 for 33% (p = 0.03), and -0.03 for 43% (p = 0.65).Pediatric abdominal MDCT can be performed with 43% of the original dose (SSDE, 7 mGy; CTDIvol, 4.3 mGy) without substantially affecting visualization of a normal appendix.


  • Patient Size Measured on CT Images as a Function of Age at a Tertiary Care Children's Hospital

    by Patricia L. Kleinman, Keith J. Strauss, David Zurakowski, Kevin S. Buckley, George A. Taylor

    OBJECTIVE. The purpose of our study was to measure patient size on CT images as a function of age at a large tertiary care children's hospital to develop current patient size data for modeling optimal x-ray exposure factors in children.MATERIALS AND METHODS. Anteroposterior and transverse dimensions of the head, thorax, abdomen, and pelvis were measured on CT examinations of pediatric patients less than 21 years old performed between June and November 2007. Patients with diseases that could affect measurements were excluded. From 1,009 patients, 336 examinations of each of four body regions were selected; 2,688 measurements were made and separated into 21 groups. Statistical model building and prediction equations were established for each region and 95% prediction intervals were used for analyses.RESULTS. Rapid growth of the head occurred from birth to approximately 2 years followed by a gradual plateau until 21 years. The thoracic, abdominal, and pelvic regions showed a linear relationship between age a...