HKHee-Joung Kim

Hee-Joung Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hee-Joung Kim has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • P. David Mozley

    Department of Radiology, University of Pennsylvania Medical Center, Philadelphia, Pennsylvania 19104

    3 shared publications
  • Hank F. Kung

    Department of Radiology, University of Pennsylvania Medical Center, Philadelphia, Pennsylvania 19104

    2 shared publications
  • Zhi-Ping Zhuang

    Departments of Radiology and Pharmacology, University of Pennsylvania, Philadelphia, Pennsylvania 19104

    2 shared publications
  • Abass Alavi

    University of Pennsylvania

    1 shared publication
  • Chyng-Yann Shiue

    Department of Radiology, University of Pennsylvania Medical Center, Philadelphia 19104, USA

    1 shared publication
  • D. Andrew Stevenson

    Departments of Radiology and Pharmacology, University of Pennsylvania, Philadelphia, Pennsylvania 19104

    1 shared publication

Latest Publications

  • p-[18F]-MPPF: A potential radioligand for PET studies of 5-HT1A receptors in humans

    by Chyng-Yann Shiue, Grace G. Shiue, P. David Mozley, Mei-Ping Kung, Zhi-Ping Zhuang, Hee-Joung Kim, Hank F. Kung

    The purpose of this study was to develop a radiopharmaceutical that could be used to selectively image 5-HT1A receptors with positron emission tomography (PET). No-carrier-added 4-(2'-methoxyphenyl)-1-[2'-(N-2"-pyridinyl)-p-[18F] fluorobenzamido]ethylpiperazine (p-[18F]-MPPF, 2) was synthesized by the nucleophilic substitution of the corresponding nitro precursor 1 with K[18F]/Kryptofix 2.2.2. in dimethyl sulfoxide (DMSO) at 140 degrees C for 20 min followed by purification with high-performance liquid chromatography (HPLC) in 10% yield in a synthesis time of 90 min from end of bombardment (EOB). Specific activity was 1-4 Ci/microM. Biodistribution studies in rats showed that the initial uptake of 2 in the brain was high (0.7% dose/g tissue at 2 min). It was then rapidly eliminated. Rates of elimination were significantly slower in brain regions with high concentrations of 5-HT1A receptors (hippocampus, cortex, and hypothalamus) than in control regions. The maximum hippocampal/cerebellar ratio was 5.6:1 at 30 min postinjection. Uptake values in serotonergic, but not in control, regions were significantly reduced by prior treatment with either (+/-)-8-OH-DPAT (2 mg/kg, i.v., 5 min prior) or WAY 100635 (1 mg/kg, i.v., 5 min prior). Radioactivity in the femur did not increase with time, suggesting that in vivo defluorination may not be the major route of metabol sm. PET studies of 2 in a monkey demonstrated selective uptake and retention of 2 in the hippocampus. The hippocampal/cerebellar ratio was 3:1 at 30 min postinjection. The ratio was reduced to 1:1 by administering (+/-)-8-OH-DPAT (2 mg/kg, i.v.) 23 min postinjection of 2. Analyses of arterial plasma by HPLC revealed that 20% of radioactivity in the plasma remained as the parent compound 2 at 30 min postinjection. The results suggest that p-[18F]-MPPF may be a useful radioligand for studying cerebral 5-HT1A receptors in humans with PET techniques.


  • In vivo SPECT imaging of 5‐HT1A receptors with [123I] p‐MPPI in nonhuman primates

    by Hank F. Kung, Dana Frederick, Hee‐Joung Kim, William McElgin, Mei‐Ping Kung, Mu Mu, P. David Mozley, Janet M. Vessotskie, D. Andrew Stevenson, Steven A. Kushner, et al.


  • Simulating technetium-99m cerebral perfusion studies with a three-dimensional Hoffman brain phantom: Collimator and filter selection in SPECT neuroimaging

    by Hee-Joung Kim, Joel S. Karp, P. David Mozley, Seoung-Oh Yang, Dae Hyuk Moon, Hank F. Kung, Hee Kyung Lee, Abass Alavi

    The choice of a collimator and the selection of a filter can affect the quality of clinical SPECT images of the brain. The compromises that 4 different collimators make between spatial resolution and sensitivity were studied by imaging a three-dimensional Hoffman brain phantom. The planar data were acquired with each collimator on a three-headed SPECT system and were reconstructed with both a standard Butterworth filter and a Wiener pre-filter. The reconstructed images were then evaluated by specialists in nuclear medicine and were also quantitatively analyzed with specific regions of interest (ROI) in the brain. All observers preferred the Wiener filter reconstructed images regardless of the collimator used to acquire the planar images. With this filter, the ultrahigh-resolution fan-beam collimator was the most subjectively preferable and quantitatively produced the highest contrast ratios. The findings support suggestions that higher resolution collimators are preferable to higher sensitivity collimators, and indicate that fan-beam collimators are preferable to parallel-hole collimators for clinical SPECT studies of cerebral perfusion. The results also suggest that the Wiener filter enhances the quality of SPECT brain images regardless of which collimator is used to acquire the data.