LBLucia Bascaran

Lucia Bascaran

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lucia Bascaran has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Javier Mendicute

    Ophthalmology Department, Donostia University Hospital, San Sebastián 20014, Spain

    4 shared publications
  • Itziar Martinez-Soroa

    Ophthalmology Department, Donostia University Hospital, San Sebastián 20014, Spain

    2 shared publications
  • Nahia Goñi

    From the Ophthalmology Department (Alberdi, Mendicute, Bascarán, Goñi), Donostia Universitary Hospital, and the Biodonostia Health Research Institute (Barandika, Ruiz Ederra), Donostia-San Sebastian, Spain

    2 shared publications
  • Txomin Alberdi

    Department of Ophthalmology, Donostia University Hospital, Donostia-San Sebastian 20014, Spain

    2 shared publications
  • Beatriz Macias-Murelaga

    1 shared publication
  • Beatriz Macías-Murelaga

    1 shared publication

Latest Publications

  • Open Access

    Differences in energy and corneal endothelium between femtosecond laser-assisted and conventional cataract surgeries: prospective, intraindividual, randomized controlled trial

    by Lucia Bascaran, Txomin Alberdi, Itziar Martinez-Soroa, Cristina Sarasqueta, Javier Mendicute

    AIM: To compare intraoperative phacoemulsification parameters and its effect on the corneal endothelium of eyes undergoing femtosecond laser-assisted cataract surgery (FLACS) versus conventional phacoemulsification (CP) cataract surgery. METHODS: Two hundred eyes from one hundred patients were included in a prospective, non-blinded, randomized, controlled, intraindividual clinical study. One hundred eyes underwent FLACS while their one hundred fellow eyes underwent CP. All surgeries were performed using the Victus (R) femtosecond laser platform and Infinity (R) Vision System phacoemulsification machine. Primary outcome measure was endothelial cell density 6mo after surgery. Secondary outcome measures included central corneal thickness (CCT), average cell area, standard deviation, coefficient of variation and hexagonality before surgery and 6mo after surgery and endothelial cell density loss during this period were also evaluated. Intraoperative efficiency parameters [cumulative dissipated energy (CDE), total intraocular surgery time, total ultrasound time, total phacoemulsification time, total torsional energy time, total aspiration time, ultrasound energy, torsional amplitude and fluid required during surgery] were also collated. RESULTS: Data from these patients was not considered for analysis. Data from 92 patients were analysed. Postoperative endothelial cell density (cells/mm(2)) between groups (2211.88 +/- 392.49 CP; 2246.31 +/- 403.48 FLACS) was not statistically significant (P=0.869). Total ultrasound time, torsional energy time, CDE and fluid requirements were significantly lower the FLACS group (P<0.05). Other parameters did not show statistically significant difference between FLACS and CP. CONCLUSION: FLACS displays significant improvements in phacoemulsification parameters in comparison to CP. There are no significant differences in corneal endothelium measures between FLACS and CP.


  • Anterior capsule opacification after femtosecond laser–assisted cataract surgery: Clinical classification versus Scheimpflug device densitometry values

    by Txomin Alberdi, Javier Mendicute, Lucía Bascarán, Nahia Goñi, Olatz Barandika, Javier Ruiz-Ederra

    None of the authors has a financial or proprietary interest in any material or method mentioned.


  • Efficacy and Stability of AT TORBI 709 M Toric IOL

    by Lucia Bascaran, Javier Mendicute, Beatriz Macias-Murelaga, Nagore Arbelaitz, Itziar Martinez-Soroa

    PURPOSE: To describe the intraocular rotational stability and refractive results of the toric AT TORBI 709 M (former AT.Comfort 464 TLC) intraocular lens (IOL) (Carl Zeiss Meditec AG, Jena, Germany). METHODS: Forty-eight eyes of 32 consecutive patients with cataract and greater than 1 diopter of corneal astigmatism were included. Implantation of the toric IOL was performed after phacoemulsification. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual refractive sphere, residual keratometric and refractive cylinders, and toric IOL axis were measured before and 1, 3, and 6 months after surgery. RESULTS: Mean logMAR UDVA and CDVA improved significantly after surgery ( P < .05). UDVA was 20/40 or better in 88.1% of eyes and 20/25 or better in 61.9%. CDVA was 20/40 or better in 100% of eyes and 20/25 or better in 90.2%. Mean refractive cylinder decreased significantly from −2.23 ± 1.72 before to −0.43 ± 0.53 after surgery ( P < .05). Vector analysis of attempted versus achieved correction showed 100% of eyes within ± 1.00 D and 95.2% within ± 0.50 D for J 0 and 100% of eyes were within ± 1.00 D and 95.2% within ± 0.50 D for J 45 . Mean toric IOL axis rotation was 4.42 ± 4.31 degrees (range: 0 to 16 degrees) and 86% of the lenses rotated less than 10 degrees. CONCLUSIONS: The AT TORBI 709 M IOL has proved to be a predictable and effective device with good rotational stability for the correction of preexisting astigmatism during cataract surgery.


  • Rotational Stability and Visual Quality in Eyes With Rayner Toric Intraocular Lens Implantation

    by Txomin Alberdi, Beatriz Macías-Murelaga, Lucía Bascarán, Nahia Goñi, Sandra Sáez de Arregui, Javier Mendicute

    PURPOSE: To assess astigmatic reduction and rotational stability of Rayner T-flex toric intraocular lenses (IOL) (573T and 623T; Rayner Intraocular Lenses Ltd) in a series of cataract surgery patients with corneal astigmatism >1.50 diopters (D). METHODS: This prospective, observational study included 27 eyes from 22 consecutive patients with pre-operative regular corneal astigmatism ⩾1.50 D in which Rayner T-flex toric IOL implantation was performed after phacoemulsification. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual refractive sphere, residual keratometric and refractive cylinder, and deviation from attempted toric IOL axis were measured. RESULTS: Mean UDVA 3 months after surgery was 0.1042±0.1290 with 20/40 or better in 96% of eyes and 20/25 or better in 52% of eyes. Mean refractive postoperative sphere was 0.25±0.37 D and mean refractive postoperative cylinder was 0.52±0.63 D. Vector analysis of attempted versus achieved visual correction showed that 100% of eyes were within ⩾1.00 D and 87% of eyes were within ⩾0.50 D. Mean change in keratometric astigmatism was 0.54±1.33 for J 0 and −0.24±1.17 for J 45 ( P >.05). Twenty-five (92.6%) eyes had IOL rotation <10°. CONCLUSIONS: Rayner T-flex toric IOL implantation is an effective and reliable option to correct preexisting astigmatism in cataract surgery.