Jon B. Stephenson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jon B. Stephenson has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Joseph Austin
Georgia Bureau of Investigation Division of Forensic Sciences, Decatur, USA
2 shared publicationsBailey Carney
Georgia Bureau of Investigation Division of Forensic Sciences, Decatur, USA
1 shared publicationDavid E. Golz
GBI Division of Forensic Sciences, P.O. Box 370808, Decatur, Georgia
1 shared publicationDenise N. Carter
Georgia Bureau of Investigation Division of Forensic Sciences
1 shared publicationJessica M Mehan
GBI Division of Forensic Sciences, P.O. Box 370808, Decatur, GA, USA
1 shared publicationLisa A Holt
GBI Division of Forensic Sciences, P.O. Box 370808, Decatur, GA, USA
1 shared publication
Latest Publications
- 24 June 2025
- Published by Springer Nature in Forensic Toxicology
- Vol. 43 (2) , 377-384
Quantitative analysis of stimulants in whole blood using an evaporation free precipitation salt assisted liquid–liquid extraction (SALLE) sample preparation approach
Purpose The increasing prevalence of methamphetamine and cocaine in postmortem toxicology casework has placed significant demands on forensic laboratories. This study introduces and validates a streamlined method using salt assisted liquid–liquid extraction (SALLE) coupled with liquid chromatography-tandem mass spectrometry (LC–MS/MS) to improve the efficiency and reliability of detecting amphetamine-type stimulants (ATS) and cocaine metabolites in forensic toxicology. Methods A new SALLE method was developed to analyze a panel of drugs, including amphetamine, methamphetamine, phentermine, 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), pseudoephedrine, cocaine, cocaethylene, and benzoylecgonine (BZE). Calibration models, bias, precision, recovery, matrix effects, interferences, limits of detection (LOD) and quantitation (LOQ), dilution integrity, carryover, and sample stability were evaluated following AAFS standard 036 guidelines. The method was applied to over 150 postmortem and human performance toxicology cases and compared with the traditional gas chromatography-mass spectrometry (GC/MS) approach. Results The SALLE-LC–MS/MS method exhibited high accuracy, with all analytes meeting bias and precision criteria (< 20%). Percent recovery values exceeded 80%, while matrix effect values (ion suppression/enhancement) remained below 20%. LODs ranged from 5–25 µg/L, and LOQs ranged from 10–50 µg/L across analytes. Processed samples were stable for up to 8 days. Analysis of 150 cases showed strong agreement with the GC/MS method, with average percent differences ranging from 5.4 to 19.4% for most analytes. The new method reduced sample preparation time by 67% and data-processing time by 80%, resulting in overall time savings of 8 h per batch. Conclusions The resulting validated SALLE procedure represents a significant advancement in the analysis of stimulant drugs within forensic toxicology. Its adoption at the Georgia Bureau of Investigation not only addresses current analytical challenges but also sets a precedent for the development of more efficient and reliable methods in the field.
- 24 June 2025
- Published by Springer Nature in Forensic Toxicology
- Vol. 43 (2) , 377-384
Quantitative analysis of stimulants in whole blood using an evaporation free precipitation salt assisted liquid–liquid extraction (SALLE) sample preparation approach
Purpose The increasing prevalence of methamphetamine and cocaine in postmortem toxicology casework has placed significant demands on forensic laboratories. This study introduces and validates a streamlined method using salt assisted liquid–liquid extraction (SALLE) coupled with liquid chromatography-tandem mass spectrometry (LC–MS/MS) to improve the efficiency and reliability of detecting amphetamine-type stimulants (ATS) and cocaine metabolites in forensic toxicology. Methods A new SALLE method was developed to analyze a panel of drugs, including amphetamine, methamphetamine, phentermine, 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), pseudoephedrine, cocaine, cocaethylene, and benzoylecgonine (BZE). Calibration models, bias, precision, recovery, matrix effects, interferences, limits of detection (LOD) and quantitation (LOQ), dilution integrity, carryover, and sample stability were evaluated following AAFS standard 036 guidelines. The method was applied to over 150 postmortem and human performance toxicology cases and compared with the traditional gas chromatography-mass spectrometry (GC/MS) approach. Results The SALLE-LC–MS/MS method exhibited high accuracy, with all analytes meeting bias and precision criteria (< 20%). Percent recovery values exceeded 80%, while matrix effect values (ion suppression/enhancement) remained below 20%. LODs ranged from 5–25 µg/L, and LOQs ranged from 10–50 µg/L across analytes. Processed samples were stable for up to 8 days. Analysis of 150 cases showed strong agreement with the GC/MS method, with average percent differences ranging from 5.4 to 19.4% for most analytes. The new method reduced sample preparation time by 67% and data-processing time by 80%, resulting in overall time savings of 8 h per batch. Conclusions The resulting validated SALLE procedure represents a significant advancement in the analysis of stimulant drugs within forensic toxicology. Its adoption at the Georgia Bureau of Investigation not only addresses current analytical challenges but also sets a precedent for the development of more efficient and reliable methods in the field.
- Open Access
- 16 June 2020
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 45 (3) , 243-251
Comprehensive Drug Screening of Whole Blood by LC–HRMS–MS in a Forensic Laboratory
As the number of prescriptions, over-the-counter medications and drugs of abuse continue to increase, forensic laboratories are faced with the challenge of developing more comprehensive screening methods in order to detect them in whole blood samples. Another challenge faced by forensic laboratories is detecting and identifying novel synthetic compounds as they emerge and change. Traditional drug screening methods include enzyme immunoassay (EIA) and either gas or liquid chromatography paired with mass spectrometry (GC–MS or LC–MS-MS, respectively). While these methods are good, they have their disadvantages. For example, EIA requires special reagents for each drug class, GC–MS requires extensive sample preparation, and LC–MS-MS only detects drugs on a known inclusion lists of compounds of interest. Described here is the development of a robust and comprehensive screening method for drugs in whole blood samples that eliminates the aforementioned disadvantages of the traditional methods. Using a Q Exactive Focus™ liquid chromatography–high-resolution accurate mass spectrometer (LC–HRMS-MS), a method was developed that is capable of detecting ~200 drugs at a concentration of 2 μg/L for most analytes. This method also employs a more automated data processing feature which reduces processing time. Finally, it has the added benefit of retroactive data analysis, which allows it to be used for unknown drug analysis as well. Used as an initial screening method, the comprehensive drug screen using LC–HRMS-MS has the potential to take on two of the most important challenges faced by forensic laboratories today.
- 16 June 2020
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 45 (3) , 243-251
Open AccessComprehensive Drug Screening of Whole Blood by LC–HRMS–MS in a Forensic Laboratory
As the number of prescriptions, over-the-counter medications and drugs of abuse continue to increase, forensic laboratories are faced with the challenge of developing more comprehensive screening methods in order to detect them in whole blood samples. Another challenge faced by forensic laboratories is detecting and identifying novel synthetic compounds as they emerge and change. Traditional drug screening methods include enzyme immunoassay (EIA) and either gas or liquid chromatography paired with mass spectrometry (GC–MS or LC–MS-MS, respectively). While these methods are good, they have their disadvantages. For example, EIA requires special reagents for each drug class, GC–MS requires extensive sample preparation, and LC–MS-MS only detects drugs on a known inclusion lists of compounds of interest. Described here is the development of a robust and comprehensive screening method for drugs in whole blood samples that eliminates the aforementioned disadvantages of the traditional methods. Using a Q Exactive Focus™ liquid chromatography–high-resolution accurate mass spectrometer (LC–HRMS-MS), a method was developed that is capable of detecting ~200 drugs at a concentration of 2 μg/L for most analytes. This method also employs a more automated data processing feature which reduces processing time. Finally, it has the added benefit of retroactive data analysis, which allows it to be used for unknown drug analysis as well. Used as an initial screening method, the comprehensive drug screen using LC–HRMS-MS has the potential to take on two of the most important challenges faced by forensic laboratories today.
- 3 November 2019
- Published by Springer Nature in Forensic Toxicology
- Vol. 38 (1) , 292-296
Surface adsorption of cannabinoids in LC–MS/MS applications
- 3 November 2019
- Published by Springer Nature in Forensic Toxicology
- Vol. 38 (1) , 292-296
Surface adsorption of cannabinoids in LC–MS/MS applications
- 25 August 2016
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 40 (8) , 649-652
Analysis of Valproic Acid, Salicylic Acid and Ibuprofen in Whole Blood by GC-MS
The Georgia Bureau of Investigation utilized a silylation method of analysis for low molecular weight carboxylic acids in the past. Due to the negative impact such derivatizations can have on gas chromatography-mass spectrometry (GC-MS) systems an alternative means of analysis was investigated. The described method is a whole blood solid phase extraction of valproic acid, salicylic acid and ibuprofen utilizing butylation for sensitivity and improved chromatography by GC-MS. The method produced a limit of detection and limit of quantitation at 1 mg/L for valproic acid, 2 mg/L for salicylic acid and 0.25 mg/L for ibuprofen. The variability based upon the middle of the calibration curve estimated to be 7% for valproic acid, 8% for salicylic acid and 11% for ibuprofen established upon a 95% confidence interval, with the highest percent coefficient of variation being 5.3% for ibuprofen.
- 25 August 2016
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 40 (8) , 649-652
Analysis of Valproic Acid, Salicylic Acid and Ibuprofen in Whole Blood by GC-MS
The Georgia Bureau of Investigation utilized a silylation method of analysis for low molecular weight carboxylic acids in the past. Due to the negative impact such derivatizations can have on gas chromatography-mass spectrometry (GC-MS) systems an alternative means of analysis was investigated. The described method is a whole blood solid phase extraction of valproic acid, salicylic acid and ibuprofen utilizing butylation for sensitivity and improved chromatography by GC-MS. The method produced a limit of detection and limit of quantitation at 1 mg/L for valproic acid, 2 mg/L for salicylic acid and 0.25 mg/L for ibuprofen. The variability based upon the middle of the calibration curve estimated to be 7% for valproic acid, 8% for salicylic acid and 11% for ibuprofen established upon a 95% confidence interval, with the highest percent coefficient of variation being 5.3% for ibuprofen.
- Open Access
- 27 August 2013
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 37 (8) , 495-499
Analysis of Buprenorphine in Whole Blood Using Liquid Chromatography-Tandem Mass Spectrometry
With buprenorphine use on the rise it has become more important than ever for the forensic laboratory to be capable of analyzing for it. Described is the approach used by the Georgia Bureau of Investigation for the screening and confirmation of buprenorphine in whole blood by liquid chromatography-tandem mass spectrometry (LC–MS-MS), along with case reviews for the first 2 months of method implementation. Screening by LC–MS-MS is capable of identifying buprenorphine cases at concentrations as low as 1–2 µg/L. Confirmatory testing is performed on both indicatively screened samples and cases where buprenorphine is specifically requested. Confirmatory analysis by LC–MS-MS has a limit of detection and limit of quantitation of 0.75 µg/L with estimated uncertainties of 7.2% at 1 µg/L, 3.5% at 10 µg/L and 4.8% at 20 µg/L based on a 95% confidence interval, with the highest percent coefficient of variation being 3.7% for the 1 µg/L level. Since its implementation, the laboratory has reported out nine cases for buprenorphine. Seven of those cases were detected by the initial screen and two were identified by a specific request for buprenorphine. The cases’ average concentration was 4.25 µg/L with a mode of 3.1 µg/L.
- 27 August 2013
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 37 (8) , 495-499
Open AccessAnalysis of Buprenorphine in Whole Blood Using Liquid Chromatography-Tandem Mass Spectrometry
With buprenorphine use on the rise it has become more important than ever for the forensic laboratory to be capable of analyzing for it. Described is the approach used by the Georgia Bureau of Investigation for the screening and confirmation of buprenorphine in whole blood by liquid chromatography-tandem mass spectrometry (LC–MS-MS), along with case reviews for the first 2 months of method implementation. Screening by LC–MS-MS is capable of identifying buprenorphine cases at concentrations as low as 1–2 µg/L. Confirmatory testing is performed on both indicatively screened samples and cases where buprenorphine is specifically requested. Confirmatory analysis by LC–MS-MS has a limit of detection and limit of quantitation of 0.75 µg/L with estimated uncertainties of 7.2% at 1 µg/L, 3.5% at 10 µg/L and 4.8% at 20 µg/L based on a 95% confidence interval, with the highest percent coefficient of variation being 3.7% for the 1 µg/L level. Since its implementation, the laboratory has reported out nine cases for buprenorphine. Seven of those cases were detected by the initial screen and two were identified by a specific request for buprenorphine. The cases’ average concentration was 4.25 µg/L with a mode of 3.1 µg/L.
- Open Access
- 16 October 2012
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 37 (1) , 25-29
Phenazepam and its Effects on Driving
Phenazepam use in the state of Georgia has increasingly become a trend for a drug market looking at new and different recreational drugs. This paper examines the psychomotor effects of phenazepam on individuals and their ability to operate a motor vehicle. This study reviewed phenazepam cases of impaired drivers that were submitted to the Georgia Bureau of Investigation's Division of Forensic Sciences between March, 2010, and August, 2011. A total of 11 cases were reviewed, of which five had only phenazepam detected and six had multiple drugs detected in addition to phenazepam. Concentrations ranged from 0.04 to 3.2 mg/L, with a median of 0.17 mg/L and a mean of 0.50 mg/L (0.23 mg/L, excluding the 3.2 mg/L blood concentration). The observed effects where symptomatic of central nervous system depression with slurred speech, lack of balance, slow reactions, drowsiness and confusion. This review indicates that the use of phenazepam at concentrations similar to other low-dose benzodiazepines such as clonazepam can have a significant impact on an individual's ability to drive.
- 16 October 2012
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 37 (1) , 25-29
Open AccessPhenazepam and its Effects on Driving
Phenazepam use in the state of Georgia has increasingly become a trend for a drug market looking at new and different recreational drugs. This paper examines the psychomotor effects of phenazepam on individuals and their ability to operate a motor vehicle. This study reviewed phenazepam cases of impaired drivers that were submitted to the Georgia Bureau of Investigation's Division of Forensic Sciences between March, 2010, and August, 2011. A total of 11 cases were reviewed, of which five had only phenazepam detected and six had multiple drugs detected in addition to phenazepam. Concentrations ranged from 0.04 to 3.2 mg/L, with a median of 0.17 mg/L and a mean of 0.50 mg/L (0.23 mg/L, excluding the 3.2 mg/L blood concentration). The observed effects where symptomatic of central nervous system depression with slurred speech, lack of balance, slow reactions, drowsiness and confusion. This review indicates that the use of phenazepam at concentrations similar to other low-dose benzodiazepines such as clonazepam can have a significant impact on an individual's ability to drive.