Mohamed Farid Shehab
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohamed Farid Shehab has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Mohammed Atef
Department of Oral and Maxillofacial Surgery, Faculty of Dentistry Cairo University Cairo Egypt
3 shared publications - Abdullah G.A. Alawlaqi1 shared publication
Ahmed A. Barakat
1 shared publication- Ahmed Farid Shehab
Faculty of Oral and Dental Medicine, Future University, Cairo, Egypt
1 shared publication Ahmed Mokhtar Elmardenly
Faculty of Oral and Dental Medicine, Cairo University, Oral and Maxillofacial Surgery Department, Cairo, Egypt
1 shared publication- Ahmed Talaat Temerek
South Valley University
1 shared publication
Latest Publications
- 17 August 2026
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
Assessment of Virtual Digital Articulation Versus Hand-Articulation Accuracy for Occlusal Registration in Orthognathic Surgery (A Randomized Clinical Trial)
Purpose: To compare the accuracy of digital occlusal articulation versus hand occlusal articulation for orthognathic surgical planning. Methods: This prospective, randomized clinical trial included 18 patients requiring orthognathic surgery, randomly assigned to a digital articulation group (n=9) or a hand articulation group (n=9). Linear displacements (X, Y, Z axes) at 5 maxillary and 5 mandibular landmarks and rotational errors (roll, pitch, and yaw) were measured postoperatively. Three blinded observers performed triplicate measurements. Interobserver reliability was assessed using intraclass correlation coefficients (ICC). Paired t tests were used for comparisons. Clinical tolerance was defined as P P =0.367). In the mandible, the digital method showed significantly larger mean error (0.720±0.281 mm) than hand (0.430±0.268 mm) ( P P =0.03), Y ( P =0.006), and Z ( P =0.005). Rotational errors were P =0.04). The largest mean linear error was 1.03 mm (digital mandibular left molar), well below the 2 mm clinical tolerance. Conclusion: Digital occlusal articulation is as accurate as hand articulation in the maxilla and produces statistically larger but clinically acceptable errors in the mandible. Both methods are reliable and suitable for orthognathic surgical planning.
- 17 August 2026
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
Assessment of Virtual Digital Articulation Versus Hand-Articulation Accuracy for Occlusal Registration in Orthognathic Surgery (A Randomized Clinical Trial)
Purpose: To compare the accuracy of digital occlusal articulation versus hand occlusal articulation for orthognathic surgical planning. Methods: This prospective, randomized clinical trial included 18 patients requiring orthognathic surgery, randomly assigned to a digital articulation group (n=9) or a hand articulation group (n=9). Linear displacements (X, Y, Z axes) at 5 maxillary and 5 mandibular landmarks and rotational errors (roll, pitch, and yaw) were measured postoperatively. Three blinded observers performed triplicate measurements. Interobserver reliability was assessed using intraclass correlation coefficients (ICC). Paired t tests were used for comparisons. Clinical tolerance was defined as P P =0.367). In the mandible, the digital method showed significantly larger mean error (0.720±0.281 mm) than hand (0.430±0.268 mm) ( P P =0.03), Y ( P =0.006), and Z ( P =0.005). Rotational errors were P =0.04). The largest mean linear error was 1.03 mm (digital mandibular left molar), well below the 2 mm clinical tolerance. Conclusion: Digital occlusal articulation is as accurate as hand articulation in the maxilla and produces statistically larger but clinically acceptable errors in the mandible. Both methods are reliable and suitable for orthognathic surgical planning.
- 28 January 2023
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 51 (4) , 217-223
Comparative study between patient specific titanium plates versus conventional miniplates for treatment of mandibular fractures: Randomized clinical trial
- 28 January 2023
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 51 (4) , 217-223
Comparative study between patient specific titanium plates versus conventional miniplates for treatment of mandibular fractures: Randomized clinical trial
- Open Access
- 22 August 2022
- Published by Universidad Tecnica de Manabi in International journal of health sciences
- p. 2735-2744
Evaluation of neurosensory disturbance after using separators vs using chisels in bilateral sagittal split osteotomy
Aim: To evaluate neurosensory disturbance after using separators Vs chisels in bilateral sagittal split osteotomy. Methods: A total of (18 patients) 36 sides indicated for BSSO randomly assigned to 2 equal parallel groups; 9 patients (18 sides) treated using chisels (control group) and 9 patients (18 sides) were treated by separators (intervention group). The neurosensory disturbance was assessed for each side. Result: After one year follow up in separator group showed neurosensory dysfunction by 11.1% while chisel group showed 44.4%. Conclusion: The use of separators (splitting forceps and elevators) led to a low percentage of persistent post-operative neurosensory dysfunction.
- 22 August 2022
- Published by Universidad Tecnica de Manabi in International journal of health sciences
- p. 2735-2744
Open AccessEvaluation of neurosensory disturbance after using separators vs using chisels in bilateral sagittal split osteotomy
Aim: To evaluate neurosensory disturbance after using separators Vs chisels in bilateral sagittal split osteotomy. Methods: A total of (18 patients) 36 sides indicated for BSSO randomly assigned to 2 equal parallel groups; 9 patients (18 sides) treated using chisels (control group) and 9 patients (18 sides) were treated by separators (intervention group). The neurosensory disturbance was assessed for each side. Result: After one year follow up in separator group showed neurosensory dysfunction by 11.1% while chisel group showed 44.4%. Conclusion: The use of separators (splitting forceps and elevators) led to a low percentage of persistent post-operative neurosensory dysfunction.
- 1 April 2021
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 67 (2) , 1111-1122
Three-Dimensional Evaluation Of The Oropharyngeal Airway Changes After Bimaxillary Orthognathic Surgery Using Cone-Beam Computer Tomography: A Retrospective Analysis
Objectives: The purpose of this study was to assess and compare the volumetric, cross sectional surface area, and linear changes of the oropharyngeal airway in patients following bimaxillary orthognathic surgery using 3-D cone beam computer tomography (CBCT) imaging. Material and Methods: A total thirty patients have been included in the study. Fifteen patients underwent maxillary and mandibular advancements (Group A), while the other fifteen patients underwent maxillary advancement and mandibular setback (Group B). Volume changes in airways, surface area, and linear values from specified hard and soft tissue parameters have been reported. Results: Statistical analysis comparing the results of the two groups showed that Group A was statistically significantly higher mean % increase than Group B in volumetric, surface area and linear measurements. Both groups failed to show a statistically significant change in surface area post-operatively. Group B showed no statistically significant change in linear measurements at any levels. Conclusion: Significant changes in the measured parameters was observed in patients performing maxillary and mandibular advancement thus increasing the airway volume; which can provide surgeons with a greater confidence that this combination movement is not altering the airway in a negative way.
- 1 April 2021
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 67 (2) , 1111-1122
Three-Dimensional Evaluation Of The Oropharyngeal Airway Changes After Bimaxillary Orthognathic Surgery Using Cone-Beam Computer Tomography: A Retrospective Analysis
Objectives: The purpose of this study was to assess and compare the volumetric, cross sectional surface area, and linear changes of the oropharyngeal airway in patients following bimaxillary orthognathic surgery using 3-D cone beam computer tomography (CBCT) imaging. Material and Methods: A total thirty patients have been included in the study. Fifteen patients underwent maxillary and mandibular advancements (Group A), while the other fifteen patients underwent maxillary advancement and mandibular setback (Group B). Volume changes in airways, surface area, and linear values from specified hard and soft tissue parameters have been reported. Results: Statistical analysis comparing the results of the two groups showed that Group A was statistically significantly higher mean % increase than Group B in volumetric, surface area and linear measurements. Both groups failed to show a statistically significant change in surface area post-operatively. Group B showed no statistically significant change in linear measurements at any levels. Conclusion: Significant changes in the measured parameters was observed in patients performing maxillary and mandibular advancement thus increasing the airway volume; which can provide surgeons with a greater confidence that this combination movement is not altering the airway in a negative way.
- 1 January 2021
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 67 (1) , 277-284
Evaluation of Virtual Surgical Planning and CAD/CAM techniques in Treatment of Mandibular Fractures via Three-Dimensional Patient-Specific Titanium Plates: A Case series.
Background: The study aimed to evaluate and assess the clinical stability and efficacy of 3D patient-specific computer-guided titanium plates (3D-PSP) for accurate reduction and fixation of mandibular fractures. Methods: Ten patients were selected suffering from mandibular body/ para-symphyseal fractures, treated with 3D-PSP. Clinical evaluation included; Patient satisfaction, Pain, Occlusion and Occlusal Bite force. Radiographic parameter evaluated was fracture gap distance. The operating time was also measured during the surgery. Results: The occlusal bite forces showed significant increase at 3 months (p≤0.05) follow up. The fracture gap distance revealed a mean of 0.64±0.40 mm at one week and 0.30±0.38 mm at 3 months. The operating time showed a mean of 8:58±02:39 mins:secs. Conclusions: 3D patient specific plates showed accurate reduction and stability of mandibular fractures with decreased operative time. Superior adaptation on bony surfaces offered increased biting forces and decreased risk of plate fracture and design flexibility avoided mental nerve damage.
- 1 January 2021
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 67 (1) , 277-284
Evaluation of Virtual Surgical Planning and CAD/CAM techniques in Treatment of Mandibular Fractures via Three-Dimensional Patient-Specific Titanium Plates: A Case series.
Background: The study aimed to evaluate and assess the clinical stability and efficacy of 3D patient-specific computer-guided titanium plates (3D-PSP) for accurate reduction and fixation of mandibular fractures. Methods: Ten patients were selected suffering from mandibular body/ para-symphyseal fractures, treated with 3D-PSP. Clinical evaluation included; Patient satisfaction, Pain, Occlusion and Occlusal Bite force. Radiographic parameter evaluated was fracture gap distance. The operating time was also measured during the surgery. Results: The occlusal bite forces showed significant increase at 3 months (p≤0.05) follow up. The fracture gap distance revealed a mean of 0.64±0.40 mm at one week and 0.30±0.38 mm at 3 months. The operating time showed a mean of 8:58±02:39 mins:secs. Conclusions: 3D patient specific plates showed accurate reduction and stability of mandibular fractures with decreased operative time. Superior adaptation on bony surfaces offered increased biting forces and decreased risk of plate fracture and design flexibility avoided mental nerve damage.
- Open Access
- 1 January 2020
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 66, 240-256
Computer guided resection and reconstruction of intra-osseous zygomatic hemangioma: Case report and systematic review of literature
To systemically integrate the available data on various published treatment strategies for intraosseous hemangioma of the zygoma in an updated comprehensive systematic review, and to present a new case of treated resection and immediate reconstruction using computer guided patient specific composite graft. A 29 years old female patient with intraosseos zygomatic hemangioma treated using computer guided resection and immediate reconstruction. The resection was performed using a resection template constructed based on preoperative 3D planning. The reconstruction was performed using ramus bone graft and titanium mesh. The patient was followed up for 3 years with no complications. An electronic search was performed on 3 data bases; additional hand search of bibliographies of selected articles was performed. Eligibility criteria include human studies presenting intraosseous zygomatico-orbital hemangioma with clearly reported therapeutic strategies. 53 articles with 73 cases were included. The lesion was highly prevalent in females compared to males (2.28:1). Fifth decade represents the highest prevalence with mean age of 44.1 ± 1.8 years. The main patient concern was swelling and facial deformity. Total tumor resection can assure no recurrence, while partial resection and curettage are associated with high recurrence rate.
- 1 January 2020
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 66, 240-256
Open AccessComputer guided resection and reconstruction of intra-osseous zygomatic hemangioma: Case report and systematic review of literature
To systemically integrate the available data on various published treatment strategies for intraosseous hemangioma of the zygoma in an updated comprehensive systematic review, and to present a new case of treated resection and immediate reconstruction using computer guided patient specific composite graft. A 29 years old female patient with intraosseos zygomatic hemangioma treated using computer guided resection and immediate reconstruction. The resection was performed using a resection template constructed based on preoperative 3D planning. The reconstruction was performed using ramus bone graft and titanium mesh. The patient was followed up for 3 years with no complications. An electronic search was performed on 3 data bases; additional hand search of bibliographies of selected articles was performed. Eligibility criteria include human studies presenting intraosseous zygomatico-orbital hemangioma with clearly reported therapeutic strategies. 53 articles with 73 cases were included. The lesion was highly prevalent in females compared to males (2.28:1). Fifth decade represents the highest prevalence with mean age of 44.1 ± 1.8 years. The main patient concern was swelling and facial deformity. Total tumor resection can assure no recurrence, while partial resection and curettage are associated with high recurrence rate.
- 12 November 2019
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 24 (1) , 19-24
Comparison of biting force when using a combination of one microplate and one miniplate versus two miniplates for fixation of parasymphyseal mandibular fracture: the use of microplates for parasymphyseal mandibular fracture
This study was to assess the efficiency of using a combination of one microplate and one miniplate for management of patients with parasymphyseal mandibular fractures versus two miniplates through measurement of the biting force.
- 12 November 2019
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 24 (1) , 19-24
Comparison of biting force when using a combination of one microplate and one miniplate versus two miniplates for fixation of parasymphyseal mandibular fracture: the use of microplates for parasymphyseal mandibular fracture
This study was to assess the efficiency of using a combination of one microplate and one miniplate for management of patients with parasymphyseal mandibular fractures versus two miniplates through measurement of the biting force.
- 1 January 2019
- Published by Egyptian Knowledge Bank in Egyptian Journal of Oral and Maxillofacial Surgery
- Vol. 10 (1) , 1-8
Density of bone formed after sinus augmentation with Nanobone versus that of bone formed after sinus lift with tenting technique : Preliminary study
Aim: Comparing the density of bone formed after sinus lifting and augmentation with Nanobone graft to that of the newly formed bone after non-augmented sinus lifting with tenting technique.Materials and Methods: A total of 12 maxillary sinuses requiring lifting and augmentation procedures were divided into two groups: Group 1: comprised six patients in which grafted maxillary sinus lifting with Nanobone graft procedures were performed, Group 2: comprised six patients in which non-grafted maxillary sinus lifting procedures were performed.Simultaneous implant placement was performed in both groups. Implants were left for six months after placement in bone to ensure complete osseointegration before loading.Results: Immediately post-operative, after 6 months and after 9 months, the mean bone density of grafted group showed statistically significantly higher value than non grafted group. This is due to the continued bone formation in the grafted group.Conclusion: There is significant increase in density of bone formed after augmented sinus lifting with Nanobone more than that of newly formed bone after non-augmented sinus lifting in the first nine months after the maxillary sinus lifting operation with simultaneous implants placement.
- 1 January 2019
- Published by Egyptian Knowledge Bank in Egyptian Journal of Oral and Maxillofacial Surgery
- Vol. 10 (1) , 1-8
Density of bone formed after sinus augmentation with Nanobone versus that of bone formed after sinus lift with tenting technique : Preliminary study
Aim: Comparing the density of bone formed after sinus lifting and augmentation with Nanobone graft to that of the newly formed bone after non-augmented sinus lifting with tenting technique.Materials and Methods: A total of 12 maxillary sinuses requiring lifting and augmentation procedures were divided into two groups: Group 1: comprised six patients in which grafted maxillary sinus lifting with Nanobone graft procedures were performed, Group 2: comprised six patients in which non-grafted maxillary sinus lifting procedures were performed.Simultaneous implant placement was performed in both groups. Implants were left for six months after placement in bone to ensure complete osseointegration before loading.Results: Immediately post-operative, after 6 months and after 9 months, the mean bone density of grafted group showed statistically significantly higher value than non grafted group. This is due to the continued bone formation in the grafted group.Conclusion: There is significant increase in density of bone formed after augmented sinus lifting with Nanobone more than that of newly formed bone after non-augmented sinus lifting in the first nine months after the maxillary sinus lifting operation with simultaneous implants placement.
- 21 February 2018
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 14 (3) , e1895
Immediate mandibular reconstruction via patient‐specific titanium mesh tray using electron beam melting/CAD/rapid prototyping techniques: One‐year follow‐up
Background: Immediate mandibular reconstruction was performed using a patient‐specific titanium mesh tray fabricated by electron beam melting (EBM) /rapid prototyping techniques.Methods: Patient‐specific titanium trays were virtually designed and fabricated using EBM technology/rapid prototyping for patients requiring mandibular resection and immediate reconstruction using an iliac crest bone graft. Dental implants were placed in the grafted sites and the patients received prosthetic rehabilitation with a follow‐up of one year. Clinical data, postoperative bone formation and complications were evaluated.Results: A symmetric appearance of facial contours was achieved. The titanium tray incorporated the particulate iliac crest bone graft that provided significant bone formation (mean 18.97 ± 1.45 mm) and predictable results. Stability of the dental implants was achieved.Conclusion: The patient‐specific titanium meshes and immediate particulate autogenous bone graft showed satisfactory clinical and surgical results in improving patients’ quality of life and decreasing the overall treatment time with adequate functional rehabilitation.
- 21 February 2018
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 14 (3) , e1895
Immediate mandibular reconstruction via patient‐specific titanium mesh tray using electron beam melting/CAD/rapid prototyping techniques: One‐year follow‐up
Background: Immediate mandibular reconstruction was performed using a patient‐specific titanium mesh tray fabricated by electron beam melting (EBM) /rapid prototyping techniques.Methods: Patient‐specific titanium trays were virtually designed and fabricated using EBM technology/rapid prototyping for patients requiring mandibular resection and immediate reconstruction using an iliac crest bone graft. Dental implants were placed in the grafted sites and the patients received prosthetic rehabilitation with a follow‐up of one year. Clinical data, postoperative bone formation and complications were evaluated.Results: A symmetric appearance of facial contours was achieved. The titanium tray incorporated the particulate iliac crest bone graft that provided significant bone formation (mean 18.97 ± 1.45 mm) and predictable results. Stability of the dental implants was achieved.Conclusion: The patient‐specific titanium meshes and immediate particulate autogenous bone graft showed satisfactory clinical and surgical results in improving patients’ quality of life and decreasing the overall treatment time with adequate functional rehabilitation.
- 1 February 2013
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 115 (2) , e16-e25
A novel design of a computer-generated splint for vertical repositioning of the maxilla after Le Fort I osteotomy
- 1 February 2013
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 115 (2) , e16-e25
A novel design of a computer-generated splint for vertical repositioning of the maxilla after Le Fort I osteotomy