Vishvanath Karande
Research Subjects
Research Interests
Vishvanath Karande has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Norbert Gleicher
Center for Human Reproduction and the Foundation for Reproductive Medicine, Chicago, Illinois, USA
3 shared publicationsJohn Rinehart
2 shared publicationsRandy Morris
2 shared publicationsAlan Korn
1 shared publicationCarli Chapman
1 shared publicationDavid Hazlett
Center for Human Reproduction and the Foundation for Reproductive Medicine, Chicago, Illinois, USA
1 shared publication
Latest Publications
- Open Access
- 8 September 2015
- Published by Springer Nature in The Journal of Obstetrics and Gynecology of India
- Vol. 65 (5) , 350-352
LigaSure™ 5-mm Blunt Tip Laparoscopic Instrument
- 8 September 2015
- Published by Springer Nature in The Journal of Obstetrics and Gynecology of India
- Vol. 65 (5) , 350-352
Open AccessLigaSure™ 5-mm Blunt Tip Laparoscopic Instrument
- Open Access
- 17 January 2011
- Published by Springer Nature in Middle East Fertility Society Journal
- Vol. 16 (1) , 101
The Fallopian Tube, Gautam N. Allahbadia, Ertan Saridogan, Ovrang Djahanbakhch (Eds.). Foreword by Ivo Brosens. Anshan Ltd. (2009). p. 723
- 17 January 2011
- Published by Springer Nature in Middle East Fertility Society Journal
- Vol. 16 (1) , 101
Open AccessThe Fallopian Tube, Gautam N. Allahbadia, Ertan Saridogan, Ovrang Djahanbakhch (Eds.). Foreword by Ivo Brosens. Anshan Ltd. (2009). p. 723
- 1 January 2003
- Published by Springer Nature in Treatments in Endocrinology
- Vol. 2 (4) , 257-272
Managing and Predicting Low Response to Standard In Vitro Fertilization Therapy
Low responders remain a difficult group of patients to manage in an in vitro fertilization (IVF) program. Such patients have low peak estradiol concentrations (in vitro maturation of oocytes are potentially exciting strategies that are still being investigated. Ultrasound measurements of ovarian volume, baseline antral follicle counts, and Doppler measurement of ovarian stromal blood flow now make it possible to predict low response to IVF therapy. Low response can be expected if the smaller ovary has a volume 3, or the mean ovarian diameter in the two longest planes is <20mm. Antral follicle counts of ≤3 in each ovary are also associated with low response. Data on ovarian stromal blood flow are still unclear, but an ovarian peak systolic velocity of <10 cm/sec is associated with low response. If low response is anticipated based on baseline ultrasound scan, a switch to one of the two effective stimulation protocols should be initiated. This would reduce cancellation rates and improve pregnancy rates in the first cycle of IVF.
- 1 January 2003
- Published by Springer Nature in Treatments in Endocrinology
- Vol. 2 (4) , 257-272
Managing and Predicting Low Response to Standard In Vitro Fertilization Therapy
Low responders remain a difficult group of patients to manage in an in vitro fertilization (IVF) program. Such patients have low peak estradiol concentrations (in vitro maturation of oocytes are potentially exciting strategies that are still being investigated. Ultrasound measurements of ovarian volume, baseline antral follicle counts, and Doppler measurement of ovarian stromal blood flow now make it possible to predict low response to IVF therapy. Low response can be expected if the smaller ovary has a volume 3, or the mean ovarian diameter in the two longest planes is <20mm. Antral follicle counts of ≤3 in each ovary are also associated with low response. Data on ovarian stromal blood flow are still unclear, but an ovarian peak systolic velocity of <10 cm/sec is associated with low response. If low response is anticipated based on baseline ultrasound scan, a switch to one of the two effective stimulation protocols should be initiated. This would reduce cancellation rates and improve pregnancy rates in the first cycle of IVF.
- 1 April 2002
- Published by Elsevier in Fertility and Sterility
- Vol. 77 (4) , 826-830
A prospective randomized comparison of the Wallace catheter and the Cook Echo-Tip® catheter for ultrasound-guided embryo transfer
- 1 April 2002
- Published by Elsevier in Fertility and Sterility
- Vol. 77 (4) , 826-830
A prospective randomized comparison of the Wallace catheter and the Cook Echo-Tip® catheter for ultrasound-guided embryo transfer
- 1 June 1999
- Published by Elsevier in Fertility and Sterility
- Vol. 71 (6) , 1001-1009
Impact of the “physician factor” on pregnancy rates in a large assisted reproductive technology program: do too many cooks spoil the broth?
- 1 June 1999
- Published by Elsevier in Fertility and Sterility
- Vol. 71 (6) , 1001-1009
Impact of the “physician factor” on pregnancy rates in a large assisted reproductive technology program: do too many cooks spoil the broth?