HYHaruo Yamauchi

Haruo Yamauchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Haruo Yamauchi has a total of 104 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Short-term lanthanum carbonate reduces calcification of cryopreserved aortic allografts in the young: A Porcine circulatory transplant model

    by Yangsin Lee, Haruo Yamauchi, Hiromichi Asahina, Minoru Ono

    Objectives Cryopreserved aortic allografts in pediatric patients have limited durability due to graft calcification, resulting in high rate of reoperations. Physiological hyperphosphatemia in the young, coupled with inflammatory responses against post-transplant allografts, accelerates allograft calcification in a rat model. We aimed to examine the anti-calcification effect of a phosphate binder, lanthanum carbonate, on aortic allografts in a growing porcine model with blood flow and pressure that resembled clinical settings. Methods Four-week-old male specific pathogen-free crossbred piglets were used as donors and recipients. The descending aortas harvested from 5 donors were divided, cryopreserved, and transplanted into the descending aorta of 10 recipient piglets. The lanthanum group received lanthanum carbonate (45 mg/kg/day for 1 week preoperatively and 4 weeks postoperatively; n = 5) and was compared to the control group (without lanthanum carbonate; n = 5). The conduits were explanted at 8 weeks and examined using von Kossa staining and for calcium content quantification by atomic absorption spectroscopy. The sera and femurs were also retrieved to analyze adverse events of lanthanum carbonate. Results In the lanthanum group, allograft medial calcification developed less frequently, and the calcium content of the allografts was significantly lower than that in controls (p = 0.009). Body weight, hematocrit levels, and femur mineral density did not differ significantly between the groups at 8 weeks. Conclusions Our results suggest that short-term lanthanum carbonate administration may alleviate cryopreserved allograft calcification in young recipients, without adverse effects.

  • Open Access

    High-Resolution CT–Based Virtual Simulation of an Unruptured Sinus of Valsalva Aneurysm for Aortic Root Reimplantation: A Case Report

    by Haruo Yamauchi, Masahiko Ando, Yasuhiro Hoshino, Hiroyuki Kaneko, Katsura Soma, Yasutaka Hirata, Minoru Ono

    INTRODUCTION: Valve-sparing aortic root replacement (VSRR) for sinus of Valsalva aneurysm (SVA) is rarely reported due to technical challenges. In this case report, high-resolution CT data were used for 3D computer graphics (3DCG) visualization and precise measurement of aortic root geometry, facilitating VSRR in a patient with a markedly disproportionate, unruptured SVA.CASE PRESENTATION: A 36-year-old female experienced heart failure at delivery. Echocardiography revealed an SVA involving a dilated noncoronary sinus (NCS) (43 mm) extending over the right atrium, a dilated sinotubular junction, and moderate aortic regurgitation (AR). To assess the feasibility of VSRR, electrocardiogram-gated CT data were analyzed in 2 ways. First, multiplanar reconstruction of CT images allowed measurement of the virtual basal ring area (566.6 mm2, corresponding to 26.9 mm), cusp angles (left-coronary, right-coronary, and noncoronary cusps: 110°, 117°, and 133°, respectively), and commissural heights (16.2, 6.3, and 19.6 mm at the non–left, left–right, and right–non intercusp commissures, respectively). Second, high-quality 3DCG images were generated to simulate the surgeon’s intraoperative view. VSRR using the reimplantation technique was performed. Under an aortic cross-clamp, the SVA wall was incised, leaving a 5-mm margin above the annulus. The subvalvular tissue beneath the SVA appeared thin and fragile. A 32-mm straight graft was plicated to 29 mm at the bottom for subvalvular fixation. For the NCS, additional running sutures were applied between the graft’s bottom skirt and the remnant SVA wall to secure hemostasis. Commissures were fixed at predicted heights based on CT measurements; one commissure required a 1-mm adjustment using the water test. Supravalvular aortic rims were then secured inside the graft with 4-0 monofilament running sutures. No additional cusp repair was necessary. The patient was weaned from cardiopulmonary bypass smoothly, and her postoperative course was uneventful. Transthoracic echocardiography at discharge showed mild AR, which remained stable after 1 year.CONCLUSIONS: This case demonstrates successful aortic root reimplantation for an unruptured SVA. CT-based aortic root visualization and measurement provided clear virtual images, facilitating surgical planning and increasing confidence in performing valve-sparing procedures for SVAs with unusual anatomy.

  • Prognostic Implications of the Periaortic Fat Attenuation Index in Uncomplicated Type B Aortic Dissection

    by Yusuke Adachi, Kazutaka Ueda, Yuka Otaki, Masaki Hashimoto, Hiroyuki Sowa, Takuya Kawahara, Genri Numata, Shun Nakamura, Munetoshi Hinata, Masae Uehara, et al.

    Periaortic fat attenuation index measured at noncontrast CT was high in patients with acute aortic dissection and predicted adverse events in uncomplicated type B aortic dissection, aiding in risk stratification and personalized treatment.


  • Open Access

    Deep Learning-Based Fully Automated Aortic Valve Leaflets and Root Measurement From Computed Tomography Images ― A Feasibility Study ―

    by Haruo Yamauchi, Gakuto Aoyama, Hiroyuki Tsukihara, Kenji Ino, Naoki Tomii, Shu Takagi, Katsuhiko Fujimoto, Takuya Sakaguchi, Ichiro Sakuma, Minoru Ono

    Background: The aim of this study was to retrain our existing deep learning-based fully automated aortic valve leaflets/root measurement algorithm, using computed tomography (CT) data for root dilatation (RD), and assess its clinical feasibility.Methods and Results: 67 ECG-gated cardiac CT scans were retrospectively collected from 40 patients with RD to retrain the algorithm. An additional 100 patients’ CT data with aortic stenosis (AS, n=50) and aortic regurgitation (AR) with/without RD (n=50) were collected to evaluate the algorithm. 45 AR patients had RD. The algorithm provided patient-specific 3-dimensional aortic valve/root visualization. The measurements of 100 cases automatically obtained by the algorithm were compared with an expert’s manual measurements. Overall, there was a moderate-to-high correlation, with differences of 6.1–13.4 mm2for the virtual basal ring area, 1.1–2.6 mm for sinus diameter, 0.1–0.6 mm for coronary artery height, 0.2–0.5 mm for geometric height, and 0.9 mm for effective height, except for the sinotubular junction of the AR cases (10.3 mm) with an indefinite borderline over the dilated sinuses, compared with 2.1 mm in AS cases. The measurement time (122 s) per case by the algorithm was significantly shorter than those of the experts (618–1,126 s).Conclusions: This fully automated algorithm can assist in evaluating aortic valve/root anatomy for planning surgical and transcatheter treatments while saving time and minimizing workload.


  • XOR-Derived ROS in Tie2-Lineage Cells Including Endothelial Cells Promotes Aortic Aneurysm Progression in Marfan Syndrome

    by Hiroki Yagi, Hiroshi Akazawa, Qing Liu, Kimiko Yamamoto, Kan Nawata, Akiko Saga-Kamo, Masahiko Umei, Hiroshi Kadowaki, Ryo Matsuoka, Akito Shindo, et al.

    BACKGROUND: Marfan syndrome (MFS) is an inherited disorder caused by mutations in the FBN1 gene encoding fibrillin-1, a matrix component of extracellular microfibrils. The main cause of morbidity and mortality in MFS is thoracic aortic aneurysm and dissection, but the underlying mechanisms remain undetermined. METHODS: To elucidate the role of endothelial XOR (xanthine oxidoreductase)–derived reactive oxygen species in aortic aneurysm progression, we inhibited in vivo function of XOR either by endothelial cell (EC)–specific disruption of the Xdh gene or by systemic administration of an XOR inhibitor febuxostat in MFS mice harboring the Fbn1 missense mutation p.(Cys1041Gly). We assessed the aberrant activation of mechanosensitive signaling in the ascending aorta of Fbn1 C1041G/+ mice. Further analysis of human aortic ECs investigated the mechanisms by which mechanical stress upregulates XOR expression. RESULTS: We found a significant increase in reactive oxygen species generation in the ascending aorta of patients with MFS and Fbn1 C1041G/+ mice, which was associated with a significant increase in protein expression and enzymatic activity of XOR protein in aortic ECs. Genetic disruption of Xdh in ECs or treatment with febuxostat significantly suppressed aortic aneurysm progression and improved perivascular infiltration of macrophages. Mechanistically, mechanosensitive signaling involving FAK (focal adhesion kinase)–p38 MAPK (p38 mitogen-activated protein kinase) and Egr-1 (early growth response-1) was aberrantly activated in the ascending aorta of Fbn1 C1041G/+ mice, and mechanical stress on human aortic ECs upregulated XOR expression through Egr-1 upregulation. Consistently, EC-specific knockout of XOR or systemic administration of febuxostat in Fbn1 C1041G/+ mice suppressed reactive oxygen species generation, FAK–p38 MAPK activation, and Egr-1 upregulation. CONCLUSIONS: Aberrant activation of mechanosensitive signaling in vascular ECs triggered endothelial XOR activation and reactive oxygen species generation, which contributes to the progression of aortic aneurysms in MFS. These findings highlight a drug repositioning approach using a uric acid–lowering drug febuxostat as a potential therapy for MFS.


  • Open Access

    Posttraumatic aortic regurgitation and root pseudoaneurysm following blunt chest trauma: a case report

    by Hiroaki Aizawa, Haruo Yamauchi, Masahiko Ando, Minoru Ono

    Background: The simultaneous diagnosis of severe aortic regurgitation and aortic root pseudoaneurysm resulting from traffic injury is extremely rare. This report presents the case of a patient with Marfan syndrome who experienced aortic root pseudoaneurysm and subacute severe aortic regurgitation following a traffic accident. Case presentation: A 64-year-old woman was diagnosed with Marfan syndrome 16 years ago and is undergoing ongoing follow-up at an outpatient clinic. Eight years previously, the patient underwent total arch replacement combined with J-graft open stent graft® (JGOS; Japan Lifeline Co., Tokyo, Japan) deployment for acute type A dissection. Five months before presentation, the patient suffered a left rib fracture in a traffic accident and received conservative management at a local hospital. The patient presented to the emergency room with worsening shortness of breath and orthopnea. Echocardiography revealed severe aortic regurgitation and moderate tricuspid regurgitation. Computed tomography revealed new-onset pseudoaneurysm at the aortic root. Surgical repair was successfully performed using a modified Bentall procedure with a bioprosthetic valve and tricuspid annuloplasty. Intraoperative findings revealed pseudoaneurysm with perforation of the right sinus of Valsalva. Although the left and right aortic valve leaflets were normal, the noncoronary leaflet exhibited a ruptured fibrous strand of a cusp fenestration, resulting in acute aortic regurgitation. Conclusions: This case report highlights the rare occurrence of aortic root pseudoaneurysm and subacute aortic regurgitation following a traffic accident. In cases of blunt chest trauma, particularly in patients with Marfan syndrome, frequent examination is crucial to assess the possibility of posttraumatic aortic regurgitation and aortic injury.

  • A beaded aneurysm of the descending aorta due to wrapping 35 years ago in a Marfan syndrome patient

    by Seimei Go, Haruo Yamauchi, Masahiko Ando, Hiroyuki Kaneko, Minoru Ono

    Seimei Go, MD, PhD, Haruo Yamauchi, MD, PhD, Masahiko Ando, MD, PhD, MPH, Hiroyuki Kaneko, MD, Minoru Ono, MD, PhD; Beaded aneurysm of the descending aorta

  • Open Access

    A case of total arch replacement in a patient with Marfan syndrome using a continuous-flow left ventricular assist device

    by Shun Tanaka, Haruo Yamauchi, Masahiko Ando, Hidetomi Takahashi, Hiroaki Aizawa, Minoru Ono

  • Open Access

    Recurrent aneurysm 11 years after thoracoabdominal aortic replacement due to recanalization of intercostal arteries of the wrapping native aorta in Marfan syndrome: a case report

    by Shun Tanaka, Haruo Yamauchi, Sachito Minegishi, Minoru Ono

    Background: Persistent blood flow is common in aortic aneurysms following endovascular repair. However, the recanalization of thrombosed intercostal arteries after open aortic repair is rare. We report a case of aortic aneurysm recurrence 11 years after thoracoabdominal aortic replacement resulting from recanalization of the intercostal arteries like a type II endoleak in a patient with Marfan syndrome. Case presentation: A 50-year-old woman with Marfan syndrome presented with left-sided back pain after meals. She underwent abdominal aortic replacement at 35 years of age, distal aortic arch and thoracoabdominal aortic replacement for type B chronic aortic dissection at 38 years of age, and aortic root to the remnant arch replacement with a mechanical valve conduit for type A acute aortic dissection at 43 years of age, which resulted in complete replacement of the entire aorta with prosthetic grafts. The patient has been taking warfarin since then. The prothrombin time-international normalized ratio levels were controlled almost within the range of 1.5–2.5 during the follow-up period, but it was elevated up to 3.4 at 1 month before she felt back pain and kept high at 4.2 on admission. Enhanced computed tomography (CT) revealed an aneurysm between the descending graft and the remaining native aortic wall, compressing the esophagus. However, there were no abnormal findings on the CT performed 10 months prior to admission. Surgery revealed that the orifices of the intercostal arteries were patent with backflow. We closed the patent intercostal arteries using nonabsorbable sutures. The patient’s postoperative course was uneventful, and the CT performed 1 year later showed no aneurysmal recurrence. Conclusions: Here, we describe a rare case of recurrent aortic aneurysm long term after graft replacement due to recanalization of the intercostal arteries of the remaining aortic wall. Our findings suggest that closing all orifices of the intercostal arteries during aortic repair, regardless of backflow, could prevent delayed reopening; systemic anticoagulation after aortic replacement may be a risk factor for recanalization, and that postoperative periodic CT follow-up is essential, especially in patients receiving anticoagulant therapy.


  • Open Access

    Automatic Aortic Valve Cusps Segmentation from CT Images Based on the Cascading Multiple Deep Neural Networks

    by Gakuto Aoyama, Longfei Zhao, Shun Zhao, Xiao Xue, Yunxin Zhong, Haruo Yamauchi, Hiroyuki Tsukihara, Eriko Maeda, Kenji Ino, Naoki Tomii, et al.

    Accurate morphological information on aortic valve cusps is critical in treatment planning. Image segmentation is necessary to acquire this information, but manual segmentation is tedious and time consuming. In this paper, we propose a fully automatic aortic valve cusps segmentation method from CT images by combining two deep neural networks, spatial configuration-Net for detecting anatomical landmarks and U-Net for segmentation of aortic valve components. A total of 258 CT volumes of end systolic and end diastolic phases, which include cases with and without severe calcifications, were collected and manually annotated for each aortic valve component. The collected CT volumes were split 6:2:2 for the training, validation and test steps, and our method was evaluated by five-fold cross validation. The segmentation was successful for all CT volumes with 69.26 s as mean processing time. For the segmentation results of the aortic root, the right-coronary cusp, the left-coronary cusp and the non-coronary cusp, mean Dice Coefficient were 0.95, 0.70, 0.69, and 0.67, respectively. There were strong correlations between measurement values automatically calculated based on the annotations and those based on the segmentation results. The results suggest that our method can be used to automatically obtain measurement values for aortic valve morphology.