H. Jonathon Mamin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
H. Jonathon Mamin has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- D. Rugar
IBM Research Division, Almaden Research Center, 650 Harry Road, San Jose, California 95120-6099
9 shared publications D. Rugar
IBM Research Division Almaden Research Center 650 Harry Rd. 95120 San Jose CA
4 shared publications- Daniel Rugar
IBM Research Division Almaden Research Center 95120 San Jose CA USA
4 shared publications M. H. Sherwood
IBM Quantum IBM Almaden Research Center 95120 San Jose CA USA
4 shared publicationsC. T. Rettner
IBM Quantum IBM Almaden Research Center 95120 San Jose CA USA
3 shared publicationsS. E. Lambert
IBM Research Division, Almaden Research Center, 650 Harry Road, San Jose, California 95120-6099
3 shared publications
Latest Publications
- Open Access
Merged-Element Transmons: Design and Qubit Performance
We have demonstrated a novel type of superconducting transmon qubit in which a Josephson junction has been engineered to act as its own parallel shunt capacitor. This merged-element transmon (MET) potentially offers a smaller footprint and simpler fabrication than conventional transmons. Because it concentrates the electromagnetic energy inside the junction, it reduces relative electric field participation from other interfaces. By combining micrometer-scale Al/AlOx/Al junctions with long oxidations and novel processing, we have produced functional devices with $E_{J}$/$E_{C}$ in the low transmon regime ($E_{J}$/$E_{C}$ $\lesssim$30). Cryogenic I-V measurements show sharp dI/dV structure with low sub-gap conduction. Qubit spectroscopy of tunable versions show a small number of avoided level crossings, suggesting the presence of two-level systems (TLS). We have observed mean T1 times typically in the range of 10-90 microseconds, with some annealed devices exhibiting T1 > 100 microseconds over several hours. The results suggest that energy relaxation in conventional, small-junction transmons is not limited by junction loss.Open AccessMerged-Element Transmons: Design and Qubit Performance
We have demonstrated a novel type of superconducting transmon qubit in which a Josephson junction has been engineered to act as its own parallel shunt capacitor. This merged-element transmon (MET) potentially offers a smaller footprint and simpler fabrication than conventional transmons. Because it concentrates the electromagnetic energy inside the junction, it reduces relative electric field participation from other interfaces. By combining micrometer-scale Al/AlOx/Al junctions with long oxidations and novel processing, we have produced functional devices with $E_{J}$/$E_{C}$ in the low transmon regime ($E_{J}$/$E_{C}$ $\lesssim$30). Cryogenic I-V measurements show sharp dI/dV structure with low sub-gap conduction. Qubit spectroscopy of tunable versions show a small number of avoided level crossings, suggesting the presence of two-level systems (TLS). We have observed mean T1 times typically in the range of 10-90 microseconds, with some annealed devices exhibiting T1 > 100 microseconds over several hours. The results suggest that energy relaxation in conventional, small-junction transmons is not limited by junction loss. - 13 August 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 16 (2) , 024023
Merged-Element Transmons: Design and Qubit Performance
We demonstrate a superconducting transmon qubit in which a Josephson junction has been engineered to act as its own parallel shunt capacitor. This merged-element transmon potentially offers a smaller footprint than conventional transmons. Because it concentrates the electromagnetic energy inside the junction, it reduces the relative electric field participation from other interfaces. By combining micrometer-scale // junctions with long oxidations, we produce functional devices with in the low-transmon regime (). Cryogenic - measurements show a sharp structure with low subgap conduction. Qubit spectroscopy of tunable versions shows a small number of avoided level crossings, suggesting the presence of two-level systems. We observe mean times typically in the range of , with some annealed devices exhibiting over several hours. The results suggest that energy relaxation in conventional small-junction transmons is not limited by junction loss.- 13 August 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 16 (2) , 024023
Merged-Element Transmons: Design and Qubit Performance
We demonstrate a superconducting transmon qubit in which a Josephson junction has been engineered to act as its own parallel shunt capacitor. This merged-element transmon potentially offers a smaller footprint than conventional transmons. Because it concentrates the electromagnetic energy inside the junction, it reduces the relative electric field participation from other interfaces. By combining micrometer-scale // junctions with long oxidations, we produce functional devices with in the low-transmon regime (). Cryogenic - measurements show a sharp structure with low subgap conduction. Qubit spectroscopy of tunable versions shows a small number of avoided level crossings, suggesting the presence of two-level systems. We observe mean times typically in the range of , with some annealed devices exhibiting over several hours. The results suggest that energy relaxation in conventional small-junction transmons is not limited by junction loss.- 10 January 2017
- Published by Springer Nature in Nature Nanotechnology
- Vol. 12 (1) , 5-6
New life for hard-disk write heads
- 10 January 2017
- Published by Springer Nature in Nature Nanotechnology
- Vol. 12 (1) , 5-6
New life for hard-disk write heads
- Open Access
Multipulse Double-Quantum Magnetometry With Near-Surface Nitrogen Vacancy Centers
We discuss multipulse magnetometry that exploits all three magnetic sublevels of the S=1 nitrogen-vacancy center in diamond to achieve enhanced magnetic field sensitivity. Based on dual frequency microwave pulsing, the scheme works in arbitrary magnetic bias fields and is twice as sensitive to ac magnetic fields as conventional two-level magnetometry. We derive the spin evolution operator for dual frequency microwave excitation and show its effectiveness for double-quantum state swaps. Using multipulse sequences of up to 128 pulses under optimized conditions, we show enhancement of the SNR by up to a factor of 2 in detecting NMR statistical signals, with a 4 times enhancement theoretically possible.
Open AccessMultipulse Double-Quantum Magnetometry With Near-Surface Nitrogen Vacancy Centers
We discuss multipulse magnetometry that exploits all three magnetic sublevels of the S=1 nitrogen-vacancy center in diamond to achieve enhanced magnetic field sensitivity. Based on dual frequency microwave pulsing, the scheme works in arbitrary magnetic bias fields and is twice as sensitive to ac magnetic fields as conventional two-level magnetometry. We derive the spin evolution operator for dual frequency microwave excitation and show its effectiveness for double-quantum state swaps. Using multipulse sequences of up to 128 pulses under optimized conditions, we show enhancement of the SNR by up to a factor of 2 in detecting NMR statistical signals, with a 4 times enhancement theoretically possible.
- 17 July 2014
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 113 (3) , 030803
Multipulse Double-Quantum Magnetometry with Near-Surface Nitrogen-Vacancy Centers
We discuss multipulse magnetometry that exploits all three magnetic sublevels of the nitrogen-vacancy center in diamond to achieve enhanced magnetic field sensitivity. Based on dual frequency microwave pulsing, the scheme is twice as sensitive to ac magnetic fields as conventional two-level magnetometry. We derive the spin evolution operator for dual frequency microwave excitation and show its effectiveness for double-quantum state swaps. Using multipulse sequences of up to 128 pulses under optimized conditions, we show enhancement of the SNR by up to a factor of 2 in detecting NMR statistical signals, with a enhancement theoretically possible.- 17 July 2014
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 113 (3) , 030803
Multipulse Double-Quantum Magnetometry with Near-Surface Nitrogen-Vacancy Centers
We discuss multipulse magnetometry that exploits all three magnetic sublevels of the nitrogen-vacancy center in diamond to achieve enhanced magnetic field sensitivity. Based on dual frequency microwave pulsing, the scheme is twice as sensitive to ac magnetic fields as conventional two-level magnetometry. We derive the spin evolution operator for dual frequency microwave excitation and show its effectiveness for double-quantum state swaps. Using multipulse sequences of up to 128 pulses under optimized conditions, we show enhancement of the SNR by up to a factor of 2 in detecting NMR statistical signals, with a enhancement theoretically possible.- 20 November 2012
- Published by American Physical Society (APS) in Physical Review B
- Vol. 86 (19)
Detecting external electron spins using nitrogen-vacancy centers
Near-surface nitrogen-vacancy (NV) centers have been created in diamond through low-energy implantation of 15N to sense electron spins that are external to the diamond. By performing double resonance experiments, we have verified the presence of g = 2 spins on a diamond crystal that was subjected to various surface treatments, including coating with a polymer film containing the free radical 2,2-diphenyl-1-picrylhydrazyl. Subsequent acid cleaning eliminated the spin signal without otherwise disrupting the NV center, providing strong evidence that the spins were at the surface. A clear correlation was observed between the strength of the external spin signal and the relaxation time T2 for the six NV centers studied. We have developed a model that takes into account the finite correlation time of the fluctuating magnetic fields generated by the external spins, and used it to infer the signal strength and correlation time of the magnetic fields from these spins. This model also highlights the sensitivity advantage of active manipulation of the longitudinal spin component via double resonance over passive detection schemes that measure the transverse component of spin.
- 20 November 2012
- Published by American Physical Society (APS) in Physical Review B
- Vol. 86 (19)
Detecting external electron spins using nitrogen-vacancy centers
Near-surface nitrogen-vacancy (NV) centers have been created in diamond through low-energy implantation of 15N to sense electron spins that are external to the diamond. By performing double resonance experiments, we have verified the presence of g = 2 spins on a diamond crystal that was subjected to various surface treatments, including coating with a polymer film containing the free radical 2,2-diphenyl-1-picrylhydrazyl. Subsequent acid cleaning eliminated the spin signal without otherwise disrupting the NV center, providing strong evidence that the spins were at the surface. A clear correlation was observed between the strength of the external spin signal and the relaxation time T2 for the six NV centers studied. We have developed a model that takes into account the finite correlation time of the fluctuating magnetic fields generated by the external spins, and used it to infer the signal strength and correlation time of the magnetic fields from these spins. This model also highlights the sensitivity advantage of active manipulation of the longitudinal spin component via double resonance over passive detection schemes that measure the transverse component of spin.
- 30 June 2011
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 21 (8)
Patterned cracks improve yield in the release of compliant microdevices from silicon-on-insulator wafers
- 30 June 2011
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 21 (8)
Patterned cracks improve yield in the release of compliant microdevices from silicon-on-insulator wafers
- Open Access
- 2 April 2008
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 100 (13) , 137601
Nuclear Spin Relaxation Induced by a Mechanical Resonator
We report on measurements of the spin lifetime of nuclear spins strongly coupled to a micromechanical cantilever as used in magnetic resonance force microscopy. We find that the rotating-frame correlation time of the statistical nuclear polarization is set by the magnetomechanical noise originating from the thermal motion of the cantilever. Evidence is based on the effect of three parameters: (1) the magnetic field gradient (the coupling strength), (2) the Rabi frequency of the spins (the transition energy), and (3) the temperature of the low-frequency mechanical modes. Experimental results are compared to relaxation rates calculated from the spectral density of the magnetomechanical noise.
- 2 April 2008
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 100 (13) , 137601
Open AccessNuclear Spin Relaxation Induced by a Mechanical Resonator
We report on measurements of the spin lifetime of nuclear spins strongly coupled to a micromechanical cantilever as used in magnetic resonance force microscopy. We find that the rotating-frame correlation time of the statistical nuclear polarization is set by the magnetomechanical noise originating from the thermal motion of the cantilever. Evidence is based on the effect of three parameters: (1) the magnetic field gradient (the coupling strength), (2) the Rabi frequency of the spins (the transition energy), and (3) the temperature of the low-frequency mechanical modes. Experimental results are compared to relaxation rates calculated from the spectral density of the magnetomechanical noise.
- 31 May 2007
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 25 (4) , 545
Magnetic resonance force microscopy — the quest for a molecular structure microscope
- 31 May 2007
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 25 (4) , 545
Magnetic resonance force microscopy — the quest for a molecular structure microscope
- 1 March 2000
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 9 (1) , 52-57
Air-bearing sliders and plane-plane-concave tips for atomic force microscope cantilevers
This paper explores strategies for fabricating and maintaining a sharp atomic force microscope (AFM) tip suitable for AFM data storage applications. To this end, AFM cantilevers have been incorporated into micromachined sled carriers and air-bearing sliders. These supports act to limit the maximum loading force on the AFM tip and allow for improved vibration immunity for the AFM cantilever in comparison to macroscopic loading schemes. Readback from a patterned rotating disk has been demonstrated using these devices. Silicon-carbide AFM cantilevers with diamond tips have been fabricated in a process compatible with that of the sleds and sliders. Molded silicon-nitride tips defined by the intersection of three surfaces have also been fabricated for AFM cantilevers. The molds for plane-plane-concave tips are defined by two silicon {111} planes and a silicon-dioxide curved surface. By geometry, the three surfaces necessarily have a unique intersection point, which may improve the consistency in sharpness of these tips relative to conventional pyramidal tips.
- 1 March 2000
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 9 (1) , 52-57
Air-bearing sliders and plane-plane-concave tips for atomic force microscope cantilevers
This paper explores strategies for fabricating and maintaining a sharp atomic force microscope (AFM) tip suitable for AFM data storage applications. To this end, AFM cantilevers have been incorporated into micromachined sled carriers and air-bearing sliders. These supports act to limit the maximum loading force on the AFM tip and allow for improved vibration immunity for the AFM cantilever in comparison to macroscopic loading schemes. Readback from a patterned rotating disk has been demonstrated using these devices. Silicon-carbide AFM cantilevers with diamond tips have been fabricated in a process compatible with that of the sleds and sliders. Molded silicon-nitride tips defined by the intersection of three surfaces have also been fabricated for AFM cantilevers. The molds for plane-plane-concave tips are defined by two silicon {111} planes and a silicon-dioxide curved surface. By geometry, the three surfaces necessarily have a unique intersection point, which may improve the consistency in sharpness of these tips relative to conventional pyramidal tips.