Christoph Zysset
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Christoph Zysset has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Gerhard Tröster
4 shared publications- Luisa Petti
Faculty of Engineering, Free University of Bozen-Bolzano, Bozen-Bolzano 39100, Italy
4 shared publications - Niko Münzenrieder
Faculty of Engineering, Free University of Bozen-Bolzano, Bozen-Bolzano 39100, Italy
4 shared publications - Giovanni Antonio Salvatore
Department of Molecular Science and Nanosystems, Cà Foscari University of Venice, Venice, Italy
3 shared publications Thomas Kinkeldei
Electronics Laboratory, Swiss Federal Institute of Technology, Gloriastrasse 35, 8092 Zürich, Switzerland
2 shared publications- Thomas Kinkeldei
Wearable Computing Lab, Swiss Federal Institute of Technology, Zurich, Switzerland
2 shared publications
Latest Publications
- 1 September 2013
- Published by Elsevier in Solid-State Electronics
- Vol. 87, 17-20
Room temperature fabricated flexible NiO/IGZO pn diode under mechanical strain
- 1 September 2013
- Published by Elsevier in Solid-State Electronics
- Vol. 87, 17-20
Room temperature fabricated flexible NiO/IGZO pn diode under mechanical strain
- 1 February 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (3) , 3213-3224
Textile integrated sensors and actuators for near-infrared spectroscopy
Being the closest layer to our body, textiles provide an ideal platform for integrating sensors and actuators to monitor physiological signals. We used a woven textile to integrate photodiodes and light emitting diodes. LEDs and photodiodes enable near-infrared spectroscopy (NIRS) systems to monitor arterial oxygen saturation and oxygenated and deoxygenated hemoglobin in human tissue. Photodiodes and LEDs are mounted on flexible plastic strips with widths of 4 mm and 2 mm, respectively. The strips are woven during the textile fabrication process in weft direction and interconnected with copper wires with a diameter of 71 μm in warp direction. The sensor textile is applied to measure the pulse waves in the fingertip and the changes in oxygenated and deoxygenated hemoglobin during a venous occlusion at the calf. The system has a signal-to-noise ratio of more than 70 dB and a system drift of 0.37% ± 0.48%. The presented work demonstrates the feasibility of integrating photodiodes and LEDs into woven textiles, a step towards wearable health monitoring devices.
- 1 February 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (3) , 3213-3224
Textile integrated sensors and actuators for near-infrared spectroscopy
Being the closest layer to our body, textiles provide an ideal platform for integrating sensors and actuators to monitor physiological signals. We used a woven textile to integrate photodiodes and light emitting diodes. LEDs and photodiodes enable near-infrared spectroscopy (NIRS) systems to monitor arterial oxygen saturation and oxygenated and deoxygenated hemoglobin in human tissue. Photodiodes and LEDs are mounted on flexible plastic strips with widths of 4 mm and 2 mm, respectively. The strips are woven during the textile fabrication process in weft direction and interconnected with copper wires with a diameter of 71 μm in warp direction. The sensor textile is applied to measure the pulse waves in the fingertip and the changes in oxygenated and deoxygenated hemoglobin during a venous occlusion at the calf. The system has a signal-to-noise ratio of more than 70 dB and a system drift of 0.37% ± 0.48%. The presented work demonstrates the feasibility of integrating photodiodes and LEDs into woven textiles, a step towards wearable health monitoring devices.
- 1 January 2013
- Published by Elsevier
Contributor contact details
- 4 December 2012
- Published by SAGE Publications in Textile Research Journal
- Vol. 83 (11) , 1130-1142
Combining electronics on flexible plastic strips with textiles
Electronic textiles are an enabling technology for a variety of applications in health care, rehabilitation or sports. In this paper, three methods to combine flexible plastic strips with textiles are discussed. Flexible plastic strips serve as carriers for electronic devices. The first approach uses a roving frame to wrap flexible plastic strips with cotton fibers. For the second method, flexible plastic strips are woven into textiles using a narrow fabric loom and a rapier loom. In the third approach, flexible plastic strips are embroidered on a shuttle embroidery machine. Due to the flexible plastic strips, electronic devices mounted on the strips are exposed to strain with the potential to damage the electronics. For the three presented methods, strain on the surface of a flexible plastic strip is investigated: roving causes strain >25%, embroidery approximately 6% and weaving 15%. Weaving flexible plastic strips is investigated in more detail because it offers possibilities to embed thin-film devices, surface mount devices and integrated circuits into textiles. Conductive yarns within the textile are used to contact the electronics. Weaving flexible plastic strips is first applied to fabricate a textile patch with woven flexible plastic strips carrying thin-film temperature sensors. In a second textile patch, a flexible plastic strip carrying an accelerometer is woven in the weft direction and connected with conductive yarns in the warp direction. The textile-integrated accelerometer can have an angular deviation of up to 10° from the textile surface. Nevertheless, applications in rehabilitation and health care can benefit from textile-integrated accelerometers.
- 4 December 2012
- Published by SAGE Publications in Textile Research Journal
- Vol. 83 (11) , 1130-1142
Combining electronics on flexible plastic strips with textiles
Electronic textiles are an enabling technology for a variety of applications in health care, rehabilitation or sports. In this paper, three methods to combine flexible plastic strips with textiles are discussed. Flexible plastic strips serve as carriers for electronic devices. The first approach uses a roving frame to wrap flexible plastic strips with cotton fibers. For the second method, flexible plastic strips are woven into textiles using a narrow fabric loom and a rapier loom. In the third approach, flexible plastic strips are embroidered on a shuttle embroidery machine. Due to the flexible plastic strips, electronic devices mounted on the strips are exposed to strain with the potential to damage the electronics. For the three presented methods, strain on the surface of a flexible plastic strip is investigated: roving causes strain >25%, embroidery approximately 6% and weaving 15%. Weaving flexible plastic strips is investigated in more detail because it offers possibilities to embed thin-film devices, surface mount devices and integrated circuits into textiles. Conductive yarns within the textile are used to contact the electronics. Weaving flexible plastic strips is first applied to fabricate a textile patch with woven flexible plastic strips carrying thin-film temperature sensors. In a second textile patch, a flexible plastic strip carrying an accelerometer is woven in the weft direction and connected with conductive yarns in the warp direction. The textile-integrated accelerometer can have an angular deviation of up to 10° from the textile surface. Nevertheless, applications in rehabilitation and health care can benefit from textile-integrated accelerometers.
- Open Access
In Tube Integrated Electronic Nose System on a Flexible Polymer Substrate
The fabrication of electronic devices, such as gas sensors on flexible polymer substrates, enables the use of electronics in applications where conventional devices on stiff substrates could not be used. We demonstrate the development of a new intra-tube electronic-nose (e-nose) gas sensor device with multiple sensors fabricated and integrated on a flexible substrate. For this purpose, we developed a new method of fabricating a sensor array of four gas sensors on a flexible polymer substrate. The method allowed the use of lithography techniques to pattern different polymers with a broad range of solubility parameters. Conductive polymer composites were used as a gas sensitive layer due to the high stretchability of the material. Each of the 30 e-nose devices on one substrate was designed to fit on a polymer strip with a width of 2 mm. A single e-nose strip was successfully integrated into the inlet tube of a gas-measurement apparatus with an inner-tube diameter of 3 mm. Using the e-nose, we were able to differentiate between four different volatile solvent vapors. The tube-integrated e-nose outperformed a chamber-integrated e-nose of the same type in terms of response time and flow-rate influences. The sensor array inside the tube showed a faster response time and detected short pulses of analyte exposure compared to the same sensor array outside of the tube. We measured gas flow rates from 1,000 to 30 sccm without significant changes in sensor performance using this intra-tube e-nose prototype. The tube could be bent to radii < 15 mm with a sensor performance similar to an unbent sensor.
Open AccessIn Tube Integrated Electronic Nose System on a Flexible Polymer Substrate
The fabrication of electronic devices, such as gas sensors on flexible polymer substrates, enables the use of electronics in applications where conventional devices on stiff substrates could not be used. We demonstrate the development of a new intra-tube electronic-nose (e-nose) gas sensor device with multiple sensors fabricated and integrated on a flexible substrate. For this purpose, we developed a new method of fabricating a sensor array of four gas sensors on a flexible polymer substrate. The method allowed the use of lithography techniques to pattern different polymers with a broad range of solubility parameters. Conductive polymer composites were used as a gas sensitive layer due to the high stretchability of the material. Each of the 30 e-nose devices on one substrate was designed to fit on a polymer strip with a width of 2 mm. A single e-nose strip was successfully integrated into the inlet tube of a gas-measurement apparatus with an inner-tube diameter of 3 mm. Using the e-nose, we were able to differentiate between four different volatile solvent vapors. The tube-integrated e-nose outperformed a chamber-integrated e-nose of the same type in terms of response time and flow-rate influences. The sensor array inside the tube showed a faster response time and detected short pulses of analyte exposure compared to the same sensor array outside of the tube. We measured gas flow rates from 1,000 to 30 sccm without significant changes in sensor performance using this intra-tube e-nose prototype. The tube could be bent to radii < 15 mm with a sensor performance similar to an unbent sensor.