FSFelix Schwab

Felix Schwab

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Felix Schwab has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Lung tumors on multimodal radiographs derived from grating-based X-ray imaging – A feasibility study

    by Felix G. Meinel, Felix Schwab, Andre Yaroshenko, Astrid Velroyen, Martin Bech, Katharina Hellbach, Jeanette Fuchs, Thorsten Stiewe, Ali Ö. Yildirim, Fabian Bamberg, et al.


  • Tracer kinetic modeling in myocardial perfusion quantification using MRI

    by Felix Schwab, Michael Ingrisch, Roy Marcus, Fabian Bamberg, Kristof Hildebrandt, Christine Adrion, Christopher Gliemi, Konstantin Nikolaou, Maximilian Reiser, Daniel Theisen

    Purpose To investigate and compare several quantification methods of myocardial perfusion measurements, paying special attention to the relation between the techniques and the required measurement duration. Methods Seven patients underwent contrast‐enhanced rest and stress cardiac perfusion measurements at 3T. Three slices were acquired in each patient and were divided into 16 segments, leading to 112 rest and stress data curves, which were analyzed using various tracer kinetic models as well as a model‐free deconvolution. Plasma flow, plasma volume, and myocardial perfusion reserve were analyzed for the complete acquisition as well as for the first pass data only. Results Deconvolution analysis yielded stable results for both rest and stress analysis, while Fermi and one compartment models agree well for first pass data (rest measurements only) and prolonged data acquisition (stress measurements only). More complex models do not yield satisfactory results for the short measurement times investigated in this study. Conclusions When performing MRI‐based quantification of myocardial perfusion, care must be taken that the method used is appropriate for the time frame under investigation. When a numerical deconvolution is used instead of tracer kinetic models, more stable results are obtained. Magn Reson Med, 2014.


  • Open Access

    Comparison of Contrast-to-Noise Ratios of Transmission and Dark-Field Signal in Grating-Based X-ray Imaging for Healthy Murine Lung Tissue

    by F. Schwab, S. Schleede, D. Hahn, M. Bech, J. Herzen, S. Auweter, F. Bamberg, K. Achterhold, A.ö. Yildirim, A. Bohla, et al.


  • Free Breathing Real-Time Cardiac Cine Imaging With Improved Spatial Resolution at 3 T

    by Felix Schwab, Florian Schwarz, Olaf Dietrich, Titus Lanz, Frank Resmer, Tobias Msc Wichmann, Bernd J. Wintersperger, Fabian Bamberg, Konstantin Nikolaou, Maximilian Md Reiser, et al.

    Objectives The aim of this study was to evaluate free-breathing single-shot real-time cine imaging for functional cardiac imaging at 3 T with increased spatial resolution. Special emphasis of this study was placed on the influence of parallel imaging techniques. Materials and Methods Gradient echo phantom images were acquired with GRAPPA and modified SENSE reconstruction using both integrated and separate reference scans as well as TGRAPPA and TSENSE. In vivo measurements were performed for GRAPPA reconstruction with an integrated and a separate reference scan, as well as TGRAPPA using balanced steady-state free precession protocols. Three clinical protocols, rtLRInt (Tres = 51.3 milliseconds; voxel, 2.5 × 5.0 × 10 mm3), rtMRSep (Tres = 48.8 milliseconds; voxel, 1.9 × 3.1 × 10 mm3), and rtHRSep (Tres = 48.3 milliseconds; voxel, 1.6 × 2.6 × 10 mm3), were investigated on 20 volunteers using GRAPPA reconstruction with internal as well as separate reference scans. End-diastolic volume, end-systolic volume, ejection fraction, peak ejection rate, peak filling rate, and myocardial mass were evaluated for the left ventricle and compared with an electrocardiogram-triggered segmented readout cine protocol used as standard of reference. All studies were performed at 3 T. Results Phantom and in vivo data demonstrate that the combination of GRAPPA reconstruction with a separate reference scan provides an optimal compromise of image quality as well as spatial and temporal resolution. Functional values (P values) for the standard of reference, rtLRInt, rtMRSep, and rtHRSep end-diastolic volume were 141 ± 24 mL, 138 ± 21 mL, 138 ± 19 mL, and 128 ± 33 mL, respectively (P = 0.7, 0.7, 0.4); end-systolic volume, 55 ± 15 mL, 61 ± 14 mL, 58 ± 12 mL, and 55 ± 20 mL, respectively (P = 0.23, 0.43, 0.62); ejection fraction, 61% ± 5%, 57% ± 5%, 58% ± 4%, and 56% ± 8%, respectively (P = 0.01, 0.11, 0.06); peak ejection rate, 481 ± 73 mL/s, 425 ± 62 mL/s, 434 ± 67 mL/s, and 381 ± 86 mL/s, respectively (P = 0.03, 0.04, 0.01); peak filling rate, 555 ± 80 mL/s, 480 ± 70 mL/s, 500 ± 70 mL/s, and 438 ± 108 mL/s, respectively (P= 0.007, 0.05, 0.004); and myocardial mass, 137 ± 26 g, 141 ± 25 g, 141 ± 23 g, and 130 ± 31 g, respectively (P = 0.62, 0.54, 0.99). Conclusions Using a separate reference scan and high acceleration factors up to R = 6, single-shot real-time cardiac imaging offers adequate temporal and spatial resolution for accurate assessment of global left ventricular function in free breathing with short examination times.