NSNicolò Speciale

Nicolò Speciale

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nicolò Speciale has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 December 2010
      • Vol. 82  (4) , 238-41

    A retrospective study to reduce prostate biopsy cores by a real time interactive tool.

    by Nicola Testoni, Nicolò Speciale, Alessandro Bertaccini, Debora Marchiori, Michelangelo Fiorentino, Fabio Manferrari, Riccardo Schiavina, Riccardo Cividini, Francesca Galluzzo, Simona Maggio, et al.

    Prostate carcinoma (PCa) is one of the most frequent neoplasms, with more than 110.000 new cases/year in Europe. As PCa is not clearly demonstrable at transrectal ultrasound (TRUS), guidelines on TRUS guided biopsy suggest to perform a random tissue sampling (at least 8-12 "cores" depending on gland volume). Although accuracy grows with core number, patient discomfort and adverse event probability grow as well. Thus it would be worth to aim to reduce the number of prostate biopsy cores without loss of diagnostic accuracy. A retrospective study was performed to evaluate the feasibility of an improved version of a rtCAB tool developed at DEIS (University of Bologna) for the reduction of prostate biopsy cores. rtCAB is an innovative processing technique which enhances TRUS video stream by a live false color overlay image that helps the physician to perform the biopsy by guiding the sampling into target zones. In order to train rtCAB, a monocentric, single operator prostate gland adenocarcinoma database has been built. The database enlists 81 patients, for a total of 743 prostate byoptic (PBx) cores and 14860 ROI. For each patient we collected age, PSA levels, digital rectal examination (DRE) findings, presence or absence of focal lesions, and prostate volume. During TRUS, raw ultrasound data were acquired and associated to each PBx core. For each core we collected both the radio frequency (RF) signal and the histological outcome. The whole system was optimized for reducing the number of false positives while preserving an acceptable number of false negatives. Comparing to a classical PBx approach (8-12 cores), the estimated positive predictive value (PPV) of our method increased from 25% to 40%, with an overall sensitivity of 85%. Preliminary results show that the proposed tool can provide real-time feedback to the operator during TRUS. Sensitivity and PPV values suggest that a reduction of almost 50% the number of biopsy cores without losing in diagnostic accuracy is feasible. A prospective study is needed to further confirm these preliminary retrospective results.

  • Thermofluid Analysis of Ultra Low Power Hotplates for a MOX Gas Sensing Device

    by Marco Messina, Francesco Franze, Nicolò Speciale, Enrico Cozzani, Alberto Roncaglia

    This work presents a full three-dimensional finite-element multiphysics simulation of the conjugate heat transfer for a gas sensing device composed by a two-element array of ultra low power (ULP) metal oxide semiconductor (MOX) sensors operated in a miniaturized sampling chamber. The heat equation in a solid, the Poisson equation for the electric potential and the incompressible Navier-Stokes and energy equations for a fluid have been solved in a coupled manner. Validation of the simulation results has been performed comparing the simulated power dissipated by the array with a set of experimental data under different operating conditions. A maximum relative error of less than 7% between the simulations and the experiments has been obtained without application of any fitting strategy on the physical properties. A negligible effect on the power dissipated by the sensor, in presence of volumetric fluxes in the sampling chamber, has been observed both numerically and experimentally. Finally, a real operational condition has been simulated and examined.


  • Wavelet Adaptivity for 3-D Device Simulation

    by Luca De Marchi, Emanuele Baravelli, Francesco Franze, Nicolò Speciale

    A new technique has been implemented with the aim of providing an adaptive tool for the generation of computational meshes for 3-D semiconductor device simulation. The core of the proposed wavelet-based adaptive method (WAM) is a refinement algorithm based on the wavelet transform, which gives an estimation of solution regularity and progressively adapts the grid by increasing the resolution only in regions where the important physical phenomena take place. WAM is inserted into a validation tool that provides the interfacing filters with both the solver and a meshing engine. Additional features assure the quality of the generated meshes by increasing the selectivity properties of the refinement tool, preventing numerical instabilities or artifacts, such as abrupt variations of I-V curves between successive bias points during quasi-stationary simulations. Simulation results are provided, which show the effectiveness of the proposed approach as a means to guide the automatic refinement of the discretization grid, preserving accuracy with negligible computational overhead and no skilled control from the user.


  • 3D simulation of conjugate heat transfer of ULP hotplates for a MOX gas sensing device

    by Marco Messina, Francesco Franze, Nicolo Speciale, Enrico Cozzani, Alberto Roncaglia

    This work presents a full three dimensional finite element multi-physics simulation of the conjugate heat transfer for a gas sensing device composed by a two-element array of Ultra Low Power (ULP) Metal Oxide Semiconductor (MOX) sensors operated in a miniaturized sampling chamber. The heat equation in a solid, the Poisson equation for the electric potential and the incompressible Navier-Stokes and energy equations for a fluid have been solved in a coupled manner. Validation of the simulation results has been performed comparing the power dissipated by the array with a set of experimental data under different operating conditions. Good agreement between the simulations and the experiments has been obtained. A small effect on the power dissipated by the sensor, in presence of volumetric fluxes in the sampling chamber, has been observed both numerically and experimentally.

  • Wavelet-based adaptive mesh generation for device simulation

    by Luca De Marchi, Francesco Franzè, Emanuele Baravelli, Nicolò Speciale