Morly Fisher

Morly Fisher

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Morly Fisher has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Neutralization of SARS-CoV-2 Variants by rVSV-ΔG-Spike-Elicited Human Sera

    by Yfat Yahalom-Ronen, Noam Erez, Morly Fisher, Hadas Tamir, Boaz Politi, Hagit Achdout, Sharon Melamed, Itai Glinert, Shay Weiss, Inbar Cohen-Gihon, et al.

    The emergence of rapidly spreading variants of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) poses a major challenge to the ability of vaccines and therapeutic antibodies to provide immunity. These variants contain mutations of specific amino acids that might impede vaccine efficacy. BriLife® (rVSV-ΔG-spike) is a newly developed SARS-CoV-2 vaccine candidate currently in phase II clinical trials. It is based on a replication-competent vesicular stomatitis virus (VSV) platform. The rVSV-ΔG-spike contains several spontaneously acquired spike mutations that correspond to SARS-CoV-2 variants’ mutations. We show that human sera from BriLife® vaccinees preserve comparable neutralization titers towards alpha, gamma, and delta variants and show less than a three-fold reduction in the neutralization capacity of beta and omicron compared to the original virus. Taken together, we show that human sera from BriLife® vaccinees overall maintain a neutralizing antibody response against all tested variants. We suggest that BriLife®-acquired mutations may prove advantageous against future SARS-CoV-2 VOCs.


  • Open Access

    Epitope Binning of Novel Monoclonal Anti F1 and Anti LcrV Antibodies and Their Application in a Simple, Short, HTRF Test for Clinical Plague Detection

    by Adva Mechaly, Einat B. Vitner, Yinon Levy, David Gur, Moria Barlev-Gross, Assa Sittner, Michal Koren, Haim Levy, Emanuelle Mamroud, Morly Fisher

    Mouse monoclonal antibodies were raised against plague disease biomarkers: the bacterial capsular protein fraction 1 (F1) and the low-calcium response—LcrV virulence factor (Vag). A novel tandem assay, employing BioLayer Interferometry (BLI), enabled the isolation of antibodies against four different epitopes on Vag. The tandem assay was carried out with hybridoma supernatants, circumventing the need for antibody purification. The BioLayer assay was further adopted for characterization of epitope-repetitive antigens, enabling the discovery of two unique epitopes on F1. The selected antibodies were purified and applied as “oligo-clonal” reagents for the immuno-detection of both biomarkers. The developed Homogenous Time Resolved Fluorescence (HTRF) tests were short (10 min) and simple (no washing steps), allowing for detection of 10 ng/mL F1 and 2.5 ng/mL Vag. The tests were successfully applied for detection of disease biomarkers produced by various Y. pestis strains during growth in blood culture vials.


  • Open Access

    Improved production of monoclonal antibodies against the LcrV antigen of Yersinia pestis using FACS-aided hybridoma selection

    by Assa Sittner, Adva Mechaly, Einat Vitner, Moshe Aftalion, Yinon Levy, Haim Levy, Emanuelle Mamroud, Morly Fisher

    For about four decades, hybridoma technologies have been the “work horse” of monoclonal antibody production. These techniques proved to be robust and reliable, albeit laborious. Over the years, several major improvements have been introduced into the field, but yet, antibody production still requires many hours of labor and considerable resources. In this work, we present a leap forward in the advancement of hybridoma-based monoclonal antibody production, which saves labor and time and increases yield, by combining hybridoma technology, fluorescent particles and fluorescence-activated cell sorting (FACS). By taking advantage of the hybridomas’ cell-surface associated antibodies, we can differentiate between antigen-specific and non-specific cells, based on their ability to bind the particles. The speed and efficiency of antibody discovery, and subsequent cell cloning, are of high importance in the field of infectious diseases. Therefore, as a model system, we chose the protein LcrV, a major virulence factor of the plague pathogen Yersinia pestis, an important re-emerging pathogen and a possible bioterror agent.


  • Simultaneous Immunodetection of Anthrax, Plague, and Tularemia from Blood Cultures by Use of Multiplexed Suspension Arrays

    by Adva Mechaly, Einat Vitner, Haim Levy, Shay Weiss, Elad Bar-David, David Gur, Michal Koren, Hila Cohen, Ofer Cohen, Emanuelle Mamroud, et al.

    Multiplexed detection technologies are becoming increasingly important given the possibility of bioterrorism attacks, for which the range of suspected pathogens can vary considerably. In this work, we describe the use of Luminex MagPlex magnetic microspheres for the construction of two multiplexed diagnostic suspension arrays, enabling antibody-based detection of bacterial pathogens and their related disease biomarkers directly from blood cultures. The first 4-plex diagnostic array enabled the detection of both anthrax and plague infections using soluble disease biomarkers, including protective antigen (PA) and anthrax capsular antigen for anthrax detection and the capsular F1 and LcrV antigens for plague detection. The limits of detection (LODs) ranged between 0.5 and 5 ng/ml for the different antigens. The second 2-plex diagnostic array facilitated the detection of Yersinia pestis (LOD of 1 × 10 6 CFU/ml) and Francisella tularensis (LOD of 1 × 10 4 CFU/ml) from blood cultures. Inoculated, propagated blood cultures were processed (15 to 20 min) via 2 possible methodologies (Vacutainer or a simple centrifugation step), allowing the direct detection of bacteria in each sample, and the entire assay could be performed in 90 min. While detection of bacteria and soluble markers from blood cultures using PCR Luminex suspension arrays has been widely described, to our knowledge, this study is the first to demonstrate the utility of the Luminex system for the immunodetection of both bacteria and soluble markers directly from blood cultures. Targeting both the bacterial pathogens as well as two different disease biomarkers for each infection, we demonstrated the benefit of the multiplexed developed assays for enhanced, reliable detection. The presented arrays could easily be expanded to include antibodies for the detection of other pathogens of interest in hospitals or labs, demonstrating the applicability of this technology for the accurate detection and confirmation of a wide range of potential select agents.


  • An internal standard approach for homogeneous TR–FRET immunoassays facilitates the detection of bacteria, biomarkers, and toxins in complex matrices

    by Noam Cohen, Eran Zahavy, Ran Zichel, Morly Fisher

    The recent development of a homogeneous time-resolved Förster resonance energy transfer (TR–FRET) immunoassay enables one-step, rapid (minutes), and direct detection compared to the multistep, time-consuming (hours), heterogeneous ELISA-type immunoassays. The use of the time-resolved effect of a donor lanthanide complex with a delay time of microseconds and large Stokes shift enables the separation of positive signals from the background autofluorescence of the sample. However, this study shows that the sample matrices directly interfere with donor fluorescence and that interference cannot be eliminated by time-resolved settings alone. Moreover, the reduction in donor emission did not appear to be equivalent to the reduction in acceptor emission, resulting in incorrect FRET signal measurements. To overcome this limitation, an internal standard approach was developed using an isotype control antibody. This new approach was used to develop TR–FRET assays for rapid detection (15–30 min) of Bacillus anthracis spores and botulinum toxin (type E) in beverages, which are major concerns in bioterrorism involving deliberate food contamination. Additionally, we demonstrate the detection of B. anthracis-secreted protective antigen (PA) and the Yersinia pestis-secreted markers F1 and LcrV in blood cultures, which are early markers of bacteremia in infected hosts following a possible bioterror attack. The use of an internal standard enables the calculation of correct ΔF values without the need for an external standard. Thus, the use of the internal standard approach in homogeneous immunoassays facilitates the examination of any sample regardless of its origin, and therefore expands the applicability of TR–FRET assays for complex matrices.


  • A Rapid Method for Bacillus anthracis Genotyping

    by Haim Levy, Morly Fisher, Naomi Ariel, Shay Weiss, Anat Zvi, David Kobiler, Zeev Altboum

  • Open Access

    A combined immunomagnetic separation and lateral flow method for a sensitive on-site detection ofBacillus anthracisspores - assessment in water and dairy products

    by M. Fisher, Y. Atiya-Nasagi, I. Simon, M. Gordin, A. Mechaly, S. Yitzhaki

    Combination of immunomagnetic separation (IMS) and lateral flow device (LFD) assays for the development of a sensitive, rapid, on-site methodology that enables concentration and detection of Bacillus anthracis spores in complex samples. The data presents the development of an optimized, 30 min, IMS assay, with about 95% capture of B. anthracis spores from different dairy products (n = 38). No cross reactivity was detected with typical milk flora and some closely related Bacilli. To enable direct application of the IMS captured spores on the LFD, spores were eluted from the bead-spore complex utilizing 95% (v/v) formamide-10 mmol l(-1) EDTA for 30 s in a microwave oven. Detached spores were analysed on LFD enabling detection within 10 min. The combined IMS-LFD methodology (40 min) demonstrates a 60-fold improvement in sensitivity, relative to samples that were applied directly on the LFD without the IMS concentrating step. The IMS-LFD method is a powerful platform, combining rapidity, specificity and efficiency for concentrating and detecting B. anthracis from water and milk contaminated samples. The combination of IMS and LFD enhances the sensitivity and flexibility of B. anthracis spore detection from complex samples. This method can potentially be extended to other toxins and micro-organisms in a variety of matrices.


  • Open Access

    Development and Implementation of a Single-Chain Fv Antibody for Specific Detection of Bacillus anthracis Spores

    by A. Mechaly, E. Zahavy, M. Fisher

    A single-chain Fv (scFv) antibody was developed and applied for efficient and specific detection of Bacillus anthracis spores. The antibody was isolated from a phage display library prepared from spleens of mice immunized with a water-soluble extract of the outer membrane of the B. anthracis spore (exosporium). The library (7 × 10 6 PFU) was biopanned against live, native B. anthracis ATCC Δ14185 spores suspended in solution, resulting in the isolation of a unique soluble scFv antibody. The antibody was affinity purified and its affinity constant (3 × 10 8 ± 1 × 10 8 M −1 ) determined via flow cytometry (FCM). Preliminary characterization of scFv specificity indicated that the scFv antibody does not cross-react with representatives of some phylogenetically related Bacillus spores. The potential use of scFv antibodies in detection platforms was demonstrated by the successful application of the soluble purified scFv antibody in enzyme-linked immunosorbent assays, immunofluorescence assays, and FCM.