Paula Peres
Research Subjects
Paula Peres has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
M. Schuhmacher
CAMECA 29 quai des Grésillons 92622 Gennevilliers Cedex France
3 shared publicationsA. Merkulov
CAMECA 29 quai des Grésillons 92622 Cedex Gennevilliers France
1 shared publication- Chiao Yu Liu
Semilab Semiconductor Physics Laboratory Co. Ltd
1 shared publication Clotilde Gaillard
Université de Lyon, Université Claude Bernard Lyon-1, Institut de Physique Nucléaire de Lyon (IPNL) , 69 622 Villeurbanne, France
1 shared publicationDenis Mangin
Institut Jean Lamour , 54 011 Nancy, France
1 shared publication- Dénes Zoltán Ullrich
Semilab Semiconductor Physics Laboratory Co. Ltd
1 shared publication
Latest Publications
- 4 September 2026
- Published by Springer Nature
- p. 243-344
Metrology for Ion Implantation Process Control
- 4 September 2026
- Published by Springer Nature
- p. 243-344
Metrology for Ion Implantation Process Control
- Open Access
- 23 March 2020
- Published by Copernicus GmbH
Innovative Detection Strategies on Large Geometry SIMS open new challenging applications for light isotope ratio analyses
Large Geometry Secondary Ion Mass Spectrometry (LG-SIMS), operating in multicollection mode, allows high precision light isotope ratio measurements at high lateral resolution (tens of μm down to sub-μm range). For some challenging applications involving fine scale analysis of low abundance isotopes (i.e. 17O or 36S) or low-concentration elements (i.e. nitrogen in diamonds) measurement of low signal intensities is required. Traditionally, count rates between the upper level of pulse counting systems ~105 c/s and the lower level of Faraday Cup (FC) measurements ~106 c/s are considered to be in a “gap area” where neither detection protocol can achieve performance better than the 1‰ level.Faraday Cup detectors (FC) offer high precision with no need for gain monitoring, however the uncertainty of FC measurements depends on the signal to noise ratio. One approach for measuring low signal intensities is to use FCs coupled to electrometers with high ohmic resistors. CAMECA LG-SIMS can now be equipped with low noise 1012 Ω resistor FC preamplifier boards for measuring signal intensities down to the ~ 3 x 105 c/s range with precision better than the 0.5‰ level (1SD).For measurement of low-abundance isotopes, a complementary approach consists of using discrete-dynode pulse counting electron multiplier (EM) detectors, for which drift and aging effects are minimized using a fast automated EM high voltage adjustment routine.During this PICO presentation, we will discuss the relevance of the detector choice (FC 1012 Ω vs EM) for few examples of innovative applications.Example of mass independent fractionation:In addition to classical isotopic ratio measurements (e.g. δ13C, δ15N, δ18O or δ34S), for which the instrumental mass fractionation (IMF) correction is mostly limited by the natural heterogeneity (chemical and isotopic) of the reference material, SIMS is particularly well suited for the measurement of mass independent fractionation (MIF, e.g. ∆33S, ∆36S and ∆17O). Along with classical geochemical processes, the degree of isotopic fractionation scales with the difference in mass of the isotopes involved (i.e. δ33S ≈ 0.515 * δ34S). MIF refers to non-conventional ratios that depart from these mass dependent rules. As instrumental mass fractionation has been shown to be strictly mass dependent, MIF measurements are not subject to IMF correction and are therefore measured directly. The use of SIMS in this specific case is particularly well suited and allows to fully explore the rich phenomenology of MIF source processes. We will discuss the advantages and disadvantages of using FC 1012 Ω for the minor Sulphur isotope (36S) measurement.Carbon and Nitrogen in diamond:We will also show a recent analytical development aiming to measure δ13C in diamonds at mass resolution of ~5000 (allowing the full separation of 13C- and 12CH-) as well as N-content and N-isotopes in diamonds at a mass resolution of ~9000 (full separation of 12C14N- and 13C13C-). For this purpose, the use of FC 1012 Ω greatly improves the data quality and allows the simultaneous measurement of N-content and δ15N.
- 23 March 2020
- Published by Copernicus GmbH
Open AccessInnovative Detection Strategies on Large Geometry SIMS open new challenging applications for light isotope ratio analyses
Large Geometry Secondary Ion Mass Spectrometry (LG-SIMS), operating in multicollection mode, allows high precision light isotope ratio measurements at high lateral resolution (tens of μm down to sub-μm range). For some challenging applications involving fine scale analysis of low abundance isotopes (i.e. 17O or 36S) or low-concentration elements (i.e. nitrogen in diamonds) measurement of low signal intensities is required. Traditionally, count rates between the upper level of pulse counting systems ~105 c/s and the lower level of Faraday Cup (FC) measurements ~106 c/s are considered to be in a “gap area” where neither detection protocol can achieve performance better than the 1‰ level.Faraday Cup detectors (FC) offer high precision with no need for gain monitoring, however the uncertainty of FC measurements depends on the signal to noise ratio. One approach for measuring low signal intensities is to use FCs coupled to electrometers with high ohmic resistors. CAMECA LG-SIMS can now be equipped with low noise 1012 Ω resistor FC preamplifier boards for measuring signal intensities down to the ~ 3 x 105 c/s range with precision better than the 0.5‰ level (1SD).For measurement of low-abundance isotopes, a complementary approach consists of using discrete-dynode pulse counting electron multiplier (EM) detectors, for which drift and aging effects are minimized using a fast automated EM high voltage adjustment routine.During this PICO presentation, we will discuss the relevance of the detector choice (FC 1012 Ω vs EM) for few examples of innovative applications.Example of mass independent fractionation:In addition to classical isotopic ratio measurements (e.g. δ13C, δ15N, δ18O or δ34S), for which the instrumental mass fractionation (IMF) correction is mostly limited by the natural heterogeneity (chemical and isotopic) of the reference material, SIMS is particularly well suited for the measurement of mass independent fractionation (MIF, e.g. ∆33S, ∆36S and ∆17O). Along with classical geochemical processes, the degree of isotopic fractionation scales with the difference in mass of the isotopes involved (i.e. δ33S ≈ 0.515 * δ34S). MIF refers to non-conventional ratios that depart from these mass dependent rules. As instrumental mass fractionation has been shown to be strictly mass dependent, MIF measurements are not subject to IMF correction and are therefore measured directly. The use of SIMS in this specific case is particularly well suited and allows to fully explore the rich phenomenology of MIF source processes. We will discuss the advantages and disadvantages of using FC 1012 Ω for the minor Sulphur isotope (36S) measurement.Carbon and Nitrogen in diamond:We will also show a recent analytical development aiming to measure δ13C in diamonds at mass resolution of ~5000 (allowing the full separation of 13C- and 12CH-) as well as N-content and N-isotopes in diamonds at a mass resolution of ~9000 (full separation of 12C14N- and 13C13C-). For this purpose, the use of FC 1012 Ω greatly improves the data quality and allows the simultaneous measurement of N-content and δ15N.
- 26 February 2018
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 36 (3) , 03F117
Dynamic SIMS for materials analysis in nuclear science
Offering high sensitivity, depth profiling and ion imaging capabilities together with high throughput, dynamic secondary ion mass spectrometry (SIMS) proves extremely useful for a wide range of nuclear science applications. The CAMECA IMS 7f/7f-Auto is a versatile magnetic sector SIMS well suited for such applications. In this work, various examples of material analyses that are of interest for nuclear science are presented: depth profiling of the xenon and mapping of contaminants in CeO2, in-depth distribution of iodine in SiC using the energy filtering technique for improving the I detection limit, and depth profiling analysis of molybdenum in UO2 using eucentric sample rotation for minimizing surface roughness development (thus improving data quality).
- 26 February 2018
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 36 (3) , 03F117
Dynamic SIMS for materials analysis in nuclear science
Offering high sensitivity, depth profiling and ion imaging capabilities together with high throughput, dynamic secondary ion mass spectrometry (SIMS) proves extremely useful for a wide range of nuclear science applications. The CAMECA IMS 7f/7f-Auto is a versatile magnetic sector SIMS well suited for such applications. In this work, various examples of material analyses that are of interest for nuclear science are presented: depth profiling of the xenon and mapping of contaminants in CeO2, in-depth distribution of iodine in SiC using the energy filtering technique for improving the I detection limit, and depth profiling analysis of molybdenum in UO2 using eucentric sample rotation for minimizing surface roughness development (thus improving data quality).
- Open Access
- 29 October 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 30 (12) , 2516-2524
Multiple ion counting measurement strategies by SIMS – a case study from nuclear safeguards and forensics
A primary tool of nuclear safeguards authorities for detecting undeclared nuclear activities is environmental sample analysis containing uranium-bearing aerosol particles. SIMS (Secondary Ion Mass Spectrometry) has been established as a powerful technique for performing uranium isotope analysis on safeguards samples. Typically, a screening of the sample for locating the particles of interest is followed by micro-beam measurements of individual particles in order to obtain their precise isotopic composition. The uncertainty of these measurements, in particular for the minor isotopes 234U and 236U, is mainly limited by the counting statistics as the total amount of uranium available is very low, usually less than 1 pg. This uncertainty can be reduced when recording several isotopes simultaneously using a multi-collection system. This has been available commercially for many years and has been used for different applications in geosciences on Large Geometry-SIMS (LG-SIMS) instruments. This paper will describe and discuss how isotope measurements of low content uranium materials can be optimized using a multi-ion counting system consisting of five discrete dynode electron multiplier (EM) detectors. The results obtained for uranium isotope ratios are presented for different measurement protocols: static multi-collector, dynamic multi-collector and single collector measurements. Some of the fundamental properties of the detector system that affect the overall measurement uncertainty are discussed. Best practices are also suggested based on the current experience.
- 29 October 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 30 (12) , 2516-2524
Open AccessMultiple ion counting measurement strategies by SIMS – a case study from nuclear safeguards and forensics
A primary tool of nuclear safeguards authorities for detecting undeclared nuclear activities is environmental sample analysis containing uranium-bearing aerosol particles. SIMS (Secondary Ion Mass Spectrometry) has been established as a powerful technique for performing uranium isotope analysis on safeguards samples. Typically, a screening of the sample for locating the particles of interest is followed by micro-beam measurements of individual particles in order to obtain their precise isotopic composition. The uncertainty of these measurements, in particular for the minor isotopes 234U and 236U, is mainly limited by the counting statistics as the total amount of uranium available is very low, usually less than 1 pg. This uncertainty can be reduced when recording several isotopes simultaneously using a multi-collection system. This has been available commercially for many years and has been used for different applications in geosciences on Large Geometry-SIMS (LG-SIMS) instruments. This paper will describe and discuss how isotope measurements of low content uranium materials can be optimized using a multi-ion counting system consisting of five discrete dynode electron multiplier (EM) detectors. The results obtained for uranium isotope ratios are presented for different measurement protocols: static multi-collector, dynamic multi-collector and single collector measurements. Some of the fundamental properties of the detector system that affect the overall measurement uncertainty are discussed. Best practices are also suggested based on the current experience.
- 5 June 2012
- Published by Wiley in Surface and Interface Analysis
- Vol. 45 (1) , 553-556
New sample holder geometry for high precision isotope analyses
Secondary ion mass spectrometry is applied to a wide range of Geoscience applications because of its capability to provide direct in situ measurement of elemental and isotopic composition. The CAMECA IMS 1280 and 1280‐HR are large geometry ultra‐high sensitivity ion microprobes that provide excellent precision and reproducibility for isotope ratio measurements. A precision at the tenth permil level is routinely achieved for the measurement of 18 O/ 16 O ratio from 10 µm spots using multicollection Faraday Cups. However, analytical artifacts related to the surface topography and to the location of the analysis in the sample (X–Y effects) are known to bias the precision for isotope analysis. The X–Y effects have been investigated using a CAMECA prototype sample holder design. Results show a significant improvement in terms of reproducibility for analyses performed over a large area of the sample. Detailed analytical data using the new sample holder will be presented. Copyright © 2012 John Wiley & Sons, Ltd.
- 5 June 2012
- Published by Wiley in Surface and Interface Analysis
- Vol. 45 (1) , 553-556
New sample holder geometry for high precision isotope analyses
Secondary ion mass spectrometry is applied to a wide range of Geoscience applications because of its capability to provide direct in situ measurement of elemental and isotopic composition. The CAMECA IMS 1280 and 1280‐HR are large geometry ultra‐high sensitivity ion microprobes that provide excellent precision and reproducibility for isotope ratio measurements. A precision at the tenth permil level is routinely achieved for the measurement of 18 O/ 16 O ratio from 10 µm spots using multicollection Faraday Cups. However, analytical artifacts related to the surface topography and to the location of the analysis in the sample (X–Y effects) are known to bias the precision for isotope analysis. The X–Y effects have been investigated using a CAMECA prototype sample holder design. Results show a significant improvement in terms of reproducibility for analyses performed over a large area of the sample. Detailed analytical data using the new sample holder will be presented. Copyright © 2012 John Wiley & Sons, Ltd.
- 15 May 2012
- Published by Wiley in Surface and Interface Analysis
- Vol. 45 (1) , 437-440
Characterization of LED materials using dynamic SIMS
Improving the manufacturing yield in light emitting diode highly competitive market requires process control strategy similar to what has been applied to integrated circuit (IC) manufacturing for years. Dynamic secondary ion mass spectrometry (SIMS) is a key analytical technique, as it provides depth profiles with excellent detection sensitivity for dopants and impurities, while keeping high analysis throughput. Dynamic SIMS data obtained using the CAMECA IMS 7f will be presented. Based on a double focusing magnetic sector mass spectrometer, this instrument achieves benchmark performance in terms of sensitivity, depth resolution and mass resolution. Depth profiling and detection limits for dopants as well as for light elements will be shown. A method for evaluating the light elements content on high purity samples will also be detailed. Copyright © 2012 John Wiley & Sons, Ltd.
- 15 May 2012
- Published by Wiley in Surface and Interface Analysis
- Vol. 45 (1) , 437-440
Characterization of LED materials using dynamic SIMS
Improving the manufacturing yield in light emitting diode highly competitive market requires process control strategy similar to what has been applied to integrated circuit (IC) manufacturing for years. Dynamic secondary ion mass spectrometry (SIMS) is a key analytical technique, as it provides depth profiles with excellent detection sensitivity for dopants and impurities, while keeping high analysis throughput. Dynamic SIMS data obtained using the CAMECA IMS 7f will be presented. Based on a double focusing magnetic sector mass spectrometer, this instrument achieves benchmark performance in terms of sensitivity, depth resolution and mass resolution. Depth profiling and detection limits for dopants as well as for light elements will be shown. A method for evaluating the light elements content on high purity samples will also be detailed. Copyright © 2012 John Wiley & Sons, Ltd.
- 11 May 2012
- Published by Wiley in Surface and Interface Analysis
- Vol. 45 (1) , 561-565
Nuclear safeguards applications using LG‐SIMS with automated screening capabilities
A primary tool for detecting undeclared nuclear activities is the analysis of uranium‐bearing particles collected on cotton swipes. For many years, secondary ion mass spectrometry (SIMS) has been used as one of the mainstay techniques for particle analysis of nuclear safeguards samples. SIMS is unique in that it is the only technique that can both localize the particles of interest and also provide the isotopic composition of single particles. This paper presents data obtained on standard uranium particle samples using large geometry (LG)‐SIMS instruments equipped with the newly developed, automated particle measurement screening software. Both sample screening measurements and microbeam analyses on individual particles are presented. The enhanced performance of the SIMS method for nuclear safeguards applications using LG‐SIMS instruments equipped with automated screening capabilities is also discussed. Copyright © 2012 John Wiley & Sons, Ltd. and Crown copyright
- 11 May 2012
- Published by Wiley in Surface and Interface Analysis
- Vol. 45 (1) , 561-565
Nuclear safeguards applications using LG‐SIMS with automated screening capabilities
A primary tool for detecting undeclared nuclear activities is the analysis of uranium‐bearing particles collected on cotton swipes. For many years, secondary ion mass spectrometry (SIMS) has been used as one of the mainstay techniques for particle analysis of nuclear safeguards samples. SIMS is unique in that it is the only technique that can both localize the particles of interest and also provide the isotopic composition of single particles. This paper presents data obtained on standard uranium particle samples using large geometry (LG)‐SIMS instruments equipped with the newly developed, automated particle measurement screening software. Both sample screening measurements and microbeam analyses on individual particles are presented. The enhanced performance of the SIMS method for nuclear safeguards applications using LG‐SIMS instruments equipped with automated screening capabilities is also discussed. Copyright © 2012 John Wiley & Sons, Ltd. and Crown copyright