YXYan Xu

Yan Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yan Xu has a total of 32 co-authors. Here are the top co-authors by number of shared publications:

  • Fangting Han

    College of Life and Environment Sciences, Shanghai Normal University,100 Guilin Road, Shanghai 200234, People's Republic of China

    2 shared publications
  • Furong Tan

    Key Laboratory of Development and Application of Rural Renewable Energy, Ministry of Agriculture and Rural Affairs, Biogas Institute of Ministry of Agriculture and Rural Affairs, Chengdu, China

    2 shared publications
  • Kai Zhao

    Key Laboratory of Agricultural Genetics and Breeding, Shanghai Academy of Agricultural Sciences, 2901 Beidi Road, Shanghai, 201106, People's Republic of China

    2 shared publications
  • Lianlong Zhu

    Key Laboratory of Agricultural Genetics and Breeding, Shanghai Academy of Agricultural Sciences, 2901 Beidi Road, Shanghai, 201106, People's Republic of China

    2 shared publications
  • Shiru Tao

    Key Laboratory of Agricultural Genetics and Breeding, Shanghai Academy of Agricultural Sciences, 2901 Beidi Road, Shanghai, 201106, People's Republic of China

    2 shared publications
  • Xueming Tang

    Key Laboratory of Agricultural Genetics and Breeding, Shanghai Academy of Agricultural Sciences, 2901 Beidi Road, Shanghai, 201106, People's Republic of China

    2 shared publications

Latest Publications

  • Open Access

    A high-throughput analysis method of microdroplet PCR coupled with fluorescence spectrophotometry

    by Yanan Du, Xiao Zhao, Binan Zhao, Yan Xu, Wei Shi, Fangfang Ren, Yangyang Wu, Ruili Hu, Xiaorui Fan, Qi Zhang, et al.

    Here we report a novel microdroplet PCR method combined with fluorescence spectrophotometry (MPFS), which allows for qualitative, quantitative and high -throughput detection of multiple DNA targets. In this study, each pair of primers was labeled with a specific fluorophore. Through microdroplet PCR, a target DNA was amplified and labeled with the same fluorophore. After products purification, the DNA products tagged with different fluorophores could be analyzed qualitatively by the fluorescent intensity determination. The relative fluorensence unit was also measured to construct the standard curve and to achieve quantitative analysis. In a reaction, the co -amplified products with different fluorophores could be simultaneously analyzed to achieve high -throughput detection. We used four kinds of GM maize as a model to confirm this theory. The qualitative results revealed high specificity and sensitivity of 0.5% (w / w). The quantitative results revealed that the limit of detection was 10 3 copies and with good repeatability. Moreover, reproducibility assay were further performed using four foodborne pathogenic bacteria. Consequently, the same qualitative, quantitative and high-throughput results were confirmed as the four GM maize.

  • Open Access

    Specific, simple and rapid detection of porcine circovirus type 2 using the loop-mediated isothermal amplification method

    by Kai Zhao, Wei Shi, Fangting Han, Yan Xu, Lianlong Zhu, Yong Zou, Xiao Wu, Hong Zhu, Furong Tan, Shiru Tao, et al.

    Background: Porcine circovirus type 2 (PCV2) is the causative agent of postweaning multisystemic wasting syndrome (PMWS), and porcine dermatitis and nephropathy syndrome (PDNS). It has caused heavy losses in global agriculture in recent decades. Rapid detection of PCV2 is very important for the effective prophylaxis and treatment of PMWS. Results: A loop-mediated isothermal amplification (LAMP) assay was used to detect PCV2 in this study. Three pairs of primers were specially designed for recognizing eight distinct sequences of the ORF2 gene. This gene lies in the PCV2 virus genome sequence, and encodes the Rep protein that is involved in virus replication. Time and temperature conditions for amplification of PCV2 genes were optimized to be 55 min at 59°C. The analysis of clinical samples indicated that the LAMP method was highly sensitive. The detection limit for PCV2 by the LAMP assay was 10 copies, whereas the limit by conventional PCR was 1000 copies. The assay did not cross-react with PCV1, porcine reproductive and respiratory syndrome virus, porcine epidemic diarrhea virus, transmissible gastroenteritis of pigs virus or rotavirus. When 110 samples were tested using the established LAMP system, 95 were detected as positive. Conclusion: The newly developed LAMP detection method for PCV2 was more specific, sensitive, rapid and simple than before. It complements and extends previous methods for PCV2 detection and provides an alternative approach for detection of PCV2.


  • Open Access

    Rapid detection of porcine circovirus type 2 using a TaqMan-based real-time PCR

    by Kai Zhao, Fangting Han, Yong Zou, Lianlong Zhu, Chunhua Li, Yan Xu, Chunling Zhang, Furong Tan, Jinbin Wang, Shiru Tao, et al.

    Porcine circovirus type 2 (PCV2) and the associated disease postweaning multisystemic wasting syndrome (PMWS) have caused heavy losses in global agriculture in recent decades. Rapid detection of PCV2 is very important for the effective prophylaxis and treatment of PMWS. To establish a sensitive, specific assay for the detection and quantitation of PCV2, we designed and synthesized specific primers and a probe in the open reading frame 2. The assay had a wide dynamic range with excellent linearity and reliable reproducibility, and detected between 102 and 1010 copies of the genomic DNA per reaction. The coefficient of variation for Ct values varied from 0.59% to 1.05% in the same assay and from 1.9% to 4.2% in 10 different assays. The assay did not cross-react with porcine circovirus type 1, porcine reproductive and respiratory, porcine epidemic diarrhea, transmissible gastroenteritis of pigs and rotavirus. The limits of detection and quantitation were 10 and 100 copies, respectively. Using the established real-time PCR system, 39 of the 40 samples we tested were detected as positive.