Lukas Schaupp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Lukas Schaupp has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Peter Beck
3 shared publications- Stephan Spat
Institute of Medical Technologies and Health Management, Joanneum Research Forschungsgesellschaft mbH, Graz, Austria
3 shared publications - Johannes Plank
Med Univ Graz, Dept Internal Med, A-8036 Graz, Austria
2 shared publications Katharina Neubauer
2 shared publicationsMartin Ellmerer
Department of Internal Medicine, Division of Endocrinology and Metabolism, Medical University of Graz, Graz, Austria
2 shared publicationsThomas R. Pieber
Department of Internal Medicine, Division of Endocrinology and Metabolism, Medical University of Graz, Graz, Austria
2 shared publications
Latest Publications
- 17 April 2014
- Published by Bioscientifica in Endocrine Abstracts
Basal bolus insulin therapy in hospitalised patients with diabetes mellitus type 2 using two algorithms embedded in a tablet PC
Current guidelines recommend pre-meal blood glucose (BG) levels of 2; refined algorithm: seven females, age 73±11 years, HbA1c 62±18 mmol/mol, and BMI 30±7 kg/m2). Mean BG was 163±34 mg/dl (initial algorithm) vs. 148±25 mg/dl (refined algorithm). 6/456 (1.3%) and 7/457 (1.5%) measurements were in the hypoglycaemic range (.
- 17 April 2014
- Published by Bioscientifica in Endocrine Abstracts
Basal bolus insulin therapy in hospitalised patients with diabetes mellitus type 2 using two algorithms embedded in a tablet PC
Current guidelines recommend pre-meal blood glucose (BG) levels of 2; refined algorithm: seven females, age 73±11 years, HbA1c 62±18 mmol/mol, and BMI 30±7 kg/m2). Mean BG was 163±34 mg/dl (initial algorithm) vs. 148±25 mg/dl (refined algorithm). 6/456 (1.3%) and 7/457 (1.5%) measurements were in the hypoglycaemic range (.
- 21 November 2013
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 406 (2) , 549-554
Recirculation—a novel approach to quantify interstitial analytes in living tissue by combining a sensor with open-flow microperfusion
We report a novel approach to quantify interstitial analytes in living tissue by combining open-flow microperfusion (OFM) with a sensor and the re-circulation method. OFM is based on the unrestricted exchange of molecules between the interstitial fluid (ISF) and a perfusion medium through macroscopic perforations that enables direct access to the ISF. By re-circulating the perfusate and monitoring the changes of the analytes’ concentration with a sensor, the absolute analyte concentration in the ISF can be calculated. In order to validate the new concept, the absolute electrical conductivity of the ISF was identified in six subjects to be 1.33 ± 0.08 S/m (coefficient of variation CV = 6 %), showing the robustness of this approach. The most striking feature of this procedure is the possibility to monitor several compounds simultaneously by applying different sensors which will allow not only the determination of the concentration of a single substance in vivo but also the simultaneous dynamics of different analytes. This will open new fields in analytical chemistry, pharmacology, as well as clinical experimental research.
- 21 November 2013
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 406 (2) , 549-554
Recirculation—a novel approach to quantify interstitial analytes in living tissue by combining a sensor with open-flow microperfusion
We report a novel approach to quantify interstitial analytes in living tissue by combining open-flow microperfusion (OFM) with a sensor and the re-circulation method. OFM is based on the unrestricted exchange of molecules between the interstitial fluid (ISF) and a perfusion medium through macroscopic perforations that enables direct access to the ISF. By re-circulating the perfusate and monitoring the changes of the analytes’ concentration with a sensor, the absolute analyte concentration in the ISF can be calculated. In order to validate the new concept, the absolute electrical conductivity of the ISF was identified in six subjects to be 1.33 ± 0.08 S/m (coefficient of variation CV = 6 %), showing the robustness of this approach. The most striking feature of this procedure is the possibility to monitor several compounds simultaneously by applying different sensors which will allow not only the determination of the concentration of a single substance in vivo but also the simultaneous dynamics of different analytes. This will open new fields in analytical chemistry, pharmacology, as well as clinical experimental research.
- 1 January 2013
- Vol. 186, 187-91
Automatic system testing of a decision support system for insulin dosing using Google Android.
Hyperglycaemia in hospitalized patients is a common and costly health care problem. The GlucoTab system is a mobile workflow and decision support system, aiming to facilitate efficient and safe glycemic control of non-critically ill patients. Being a medical device, the GlucoTab requires extensive and reproducible testing. A framework for high-volume, reproducible and automated system testing of the GlucoTab system was set up applying several Open Source tools for test automation and system time handling. The REACTION insulin titration protocol was investigated in a paper-based clinical trial (PBCT). In order to validate the GlucoTab system, data from this trial was used for simulation and system tests. In total, 1190 decision support action points were identified and simulated. Four data points (0.3%) resulted in a GlucoTab system error caused by a defective implementation. In 144 data points (12.1%), calculation errors of physicians and nurses in the PBCT were detected. The test framework was able to verify manual calculation of insulin doses and detect relatively many user errors and workflow anomalies in the PBCT data. This shows the high potential of the electronic decision support application to improve safety of implementation of an insulin titration protocol and workflow management system in clinical wards.
- 1 January 2013
- Vol. 186, 187-91
Automatic system testing of a decision support system for insulin dosing using Google Android.
Hyperglycaemia in hospitalized patients is a common and costly health care problem. The GlucoTab system is a mobile workflow and decision support system, aiming to facilitate efficient and safe glycemic control of non-critically ill patients. Being a medical device, the GlucoTab requires extensive and reproducible testing. A framework for high-volume, reproducible and automated system testing of the GlucoTab system was set up applying several Open Source tools for test automation and system time handling. The REACTION insulin titration protocol was investigated in a paper-based clinical trial (PBCT). In order to validate the GlucoTab system, data from this trial was used for simulation and system tests. In total, 1190 decision support action points were identified and simulated. Four data points (0.3%) resulted in a GlucoTab system error caused by a defective implementation. In 144 data points (12.1%), calculation errors of physicians and nurses in the PBCT were detected. The test framework was able to verify manual calculation of insulin doses and detect relatively many user errors and workflow anomalies in the PBCT data. This shows the high potential of the electronic decision support application to improve safety of implementation of an insulin titration protocol and workflow management system in clinical wards.
- 1 January 2012
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 45 (18) , 420-425
A new Perspective on Closed-Loop Glucose Control using a Physiology-Based Pharmacokinetic / Pharmacodynamic Model Kernel
- 1 January 2012
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 45 (18) , 420-425
A new Perspective on Closed-Loop Glucose Control using a Physiology-Based Pharmacokinetic / Pharmacodynamic Model Kernel
- 1 February 2011
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 13 (2) , 127-134
Prediction of Glucose Concentration in Post-Cardiothoracic Surgery Patients Using Continuous Glucose Monitoring
Objective: This study evaluated the predictive capability of simple linear extrapolation of continuous glucose data in postsurgical patients undergoing intensive care. Methods: Twenty patients, both with or without an established diagnosis of diabetes mellitus, scheduled to undergo cardiothoracic surgery were included. Glucose was continuously monitored in the intensive care unit with a microdialysis-based subcutaneous glucose monitoring system. The prediction horizon (PH) with respect to a given glucose reading was calculated by extrapolating the linear trend of the glucose signal and subjected to both analytical and clinical assessment (by calculation of the average duration of consecutive positive and negative glucose signal trends, the root mean squared error [RMSE], and by insulin titration error grid [ITEG] analysis, respectively). Results: In total, 609 h of continuous glucose data from 17 patients were analyzed. The average duration of consecutive positive and negative glucose signal trends was 7.97 (3.99–19.98) min (median, interquartile range). An increase in the RMSE of 0.5 mmol/L (9 mg/dL) was associated with a PH of 37 min. A strong increase in the number of data points in the unacceptable violation zone of the ITEG was associated with a PH of approximately 20 min. Conclusions: Our data provide evidence that simple linear extrapolation of glucose trend information obtained by continuous glucose monitoring can be used to predict the course of glycemia in critically ill patients for up to 20–30 min. This “glimpse into the future” can be used to proactively prevent the occurrence of adverse events.
- 1 February 2011
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 13 (2) , 127-134
Prediction of Glucose Concentration in Post-Cardiothoracic Surgery Patients Using Continuous Glucose Monitoring
Objective: This study evaluated the predictive capability of simple linear extrapolation of continuous glucose data in postsurgical patients undergoing intensive care. Methods: Twenty patients, both with or without an established diagnosis of diabetes mellitus, scheduled to undergo cardiothoracic surgery were included. Glucose was continuously monitored in the intensive care unit with a microdialysis-based subcutaneous glucose monitoring system. The prediction horizon (PH) with respect to a given glucose reading was calculated by extrapolating the linear trend of the glucose signal and subjected to both analytical and clinical assessment (by calculation of the average duration of consecutive positive and negative glucose signal trends, the root mean squared error [RMSE], and by insulin titration error grid [ITEG] analysis, respectively). Results: In total, 609 h of continuous glucose data from 17 patients were analyzed. The average duration of consecutive positive and negative glucose signal trends was 7.97 (3.99–19.98) min (median, interquartile range). An increase in the RMSE of 0.5 mmol/L (9 mg/dL) was associated with a PH of 37 min. A strong increase in the number of data points in the unacceptable violation zone of the ITEG was associated with a PH of approximately 20 min. Conclusions: Our data provide evidence that simple linear extrapolation of glucose trend information obtained by continuous glucose monitoring can be used to predict the course of glycemia in critically ill patients for up to 20–30 min. This “glimpse into the future” can be used to proactively prevent the occurrence of adverse events.
- 1 January 2011
- Vol. 169, 950-4
Design of a mobile, safety-critical in-patient glucose management system.
Diabetes mellitus is one of the most widespread diseases in the world. People with diabetes usually have long stays in hospitals and need specific treatment. In order to support in-patient care, we designed a prototypical mobile in-patient glucose management system with decision support for insulin dosing. In this paper we discuss the engineering process and the lessons learned from the iterative design and development phases of the prototype. We followed a user-centered development process, including real-life usability testing from the outset. Paper mock-ups in particular proved to be very valuable in gaining insight into the workflows and processes, with the result that user interfaces could be designed exactly to the specific needs of the hospital personnel in their daily routine.
- 1 January 2011
- Vol. 169, 950-4
Design of a mobile, safety-critical in-patient glucose management system.
Diabetes mellitus is one of the most widespread diseases in the world. People with diabetes usually have long stays in hospitals and need specific treatment. In order to support in-patient care, we designed a prototypical mobile in-patient glucose management system with decision support for insulin dosing. In this paper we discuss the engineering process and the lessons learned from the iterative design and development phases of the prototype. We followed a user-centered development process, including real-life usability testing from the outset. Paper mock-ups in particular proved to be very valuable in gaining insight into the workflows and processes, with the result that user interfaces could be designed exactly to the specific needs of the hospital personnel in their daily routine.