TBTiago José Belli

Tiago José Belli

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tiago José Belli has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Integrating sequencing batch hybrid membrane bioreactor with ozonation for treatment of tissue paper wastewater

    by Fernanda Filipaki, Tiago José Belli, André Aguiar Battistelli, Jeanette Beber de Souza, Carlos Magno de Sousa Vidal

    This study assessed the performance of a sequencing batch hybrid membrane bioreactor (SB-HMBR) coupled with ozonation for the treatment of tissue paper wastewater. The SB-HMBR was operated for 90 d with a cycle time of 8.5 h under two aeration intensities, corresponding to specific aeration demand per membrane area (SADₘ) of 0.32 and 0.16 m 3 m⁻ 2 h⁻ 1 . The permeate obtained under the lower aeration regime was further subjected to batch ozonation (3 and 4 g O 3 h − 1 ). Despite substantial variations in influent COD between Phase I (417 mg L − 1 ) and Phase II (279 mg L − 1 ), with BOD₅ values of 46 and 45 mg L − 1 , the reactor maintained stable performance, achieving COD removals of 91% and 78%, respectively, with complete BOD₅ removal. Ammonium removal decreased from 75% to 65% under reduced aeration, reflecting the sensitivity of nitrification to oxygen limitation, while phosphorus removal remained low (30–44%). Phenolic compound removal and color reduction ranged from 70 to 78% and 65–74%, respectively. UV–vis analysis indicated that chromophore attenuation resulted from the combined effects of biodegradation and membrane separation, with no significant changes in removal patterns under reduced aeration. Ozonation significantly improved permeate quality, achieving color removal of 90–92% and phenolic compound reduction of 47–48%. However, soluble COD exhibited transient increases, indicating partial oxidation of macromolecules into more soluble intermediates. Overall, the SB-HMBR coupled with ozonation provided an effective strategy for tissue paper wastewater treatment, ensuring stable performance and efficient effluent polishing under reduced aeration conditions.

  • Open Access

    Low electric charge loading in a sequencing batch electro-membrane bioreactor: influence of aeration intensity on treatment performance, biomass activity, and membrane fouling

    by Tiago José Belli, Emerson Souza, Caroline Rodrigues, André Aguiar Battistelli, Wanderli Leite, Miriam Cristina Santos Amaral, Flávio Rubens Lapolli

    This study investigates the performance of a sequencing batch electro-membrane bioreactor (SB-EMBR) operated under low electric charge loading (39.9 mAh L⁻ 1 ), focusing on the effects of aeration intensity on treatment performance, biomass activity, and membrane fouling. The reactor was operated at a current density of 10 A m −2 and three specific aeration demand levels (SADₘ = 0.48, 0.24, and 0.12 m 3 m⁻ 2 h⁻ 1 ). Organic matter and phosphorus removals remained consistently high (> 90% COD removal; TP < 1.0 mg L⁻ 1 ) regardless of aeration intensity. In contrast, ammonium removal efficiency declined from 99.5 to 74.7% as the SADₘ decreased from 0.48 to 0.12 m 3 m⁻ 2 h⁻ 1 . Batch assays revealed reduced activity of polyphosphate-accumulating organisms under oxygen-limited conditions. The pronounced decrease in the P-release/COD-uptake ratio from 0.172 to 0.0164 mol P mol⁻ 1 C indicates that TP removal at low dissolved oxygen became predominantly governed by chemical coagulation rather than the biological phosphorus removal process. The calculated Al/P molar ratio of 2.32 mol Al mol⁻ 1 P was sufficient to sustain phosphorus removal through both precipitation and adsorption onto aluminum hydroxides. Reduced aeration favored anoxic phosphorus uptake, increasing the denitrifying phosphate assimilation potential from 18 to 41%. The membrane fouling rate increased from 1.02 to 4.81 kPa d⁻ 1 as aeration decreased, mainly due to diminished shear forces, soluble microbial products accumulation (+ 205%), floc size reduction (− 50.1%), and higher capillary suction time (+ 123%). Owing to the short current application (1.6 h d⁻ 1 ), the additional electrocoagulation cost was only 0.07 USD m⁻ 3 , lower than values reported for continuous-flow EMBRs. Overall, operation of the SB-EMBR under reduced electric charge loading demonstrated promising energy efficiency while maintaining stable and satisfactory pollutant removal even at low aeration intensities.

  • Open Access

    Bioelectrochemical hybrid system integrating anodic biofilm and cathodic Fenton into a microbial fuel cell for multifunctional treatment of azo dye wastewater

    by Carlos Eduardo Lach, Daniele Damasceno Silveira, Tiago José Belli, Flávio Rubens Lapolli, María Ángeles Lobo-Recio


  • Open Access

    Phosphorus removal in membrane bioreactor systems: a systematic review of operational parameters and configurations

    by Renata de Arcega Leal, Amanda Dalalibera-Nunes, André Aguiar Battistelli, Tiago José Belli, Maria Eliza Nagel-Hassemer, Gabriel Tochetto

    Phosphorus (P) is an essential yet finite resource, and concerns about its availability are intensified by population growth, urbanization, and increasing food demand, while stringent discharge regulations are required to protect aquatic ecosystems from eutrophication. Membrane bioreactors (MBRs) combine biological treatment with membrane separation, enabling high effluent quality and supporting water reuse; however, the literature reports P performance in ways that are difficult to compare across studies. This systematic review screened 854 Scopus records (2014–2025) and synthesized 29 eligible bench- and pilot-scale studies reporting at least one operational parameter (transmembrane pressure (TMP), hydraulic retention time (HRT), sludge retention time (SRT), or aeration) alongside P performance. Its novelty lies in linking operational settings to performance separately for each P fraction, distinguishing true dissolved-P removal from particulate retention by the membrane, a distinction rarely made in earlier reviews. High total phosphorus (TP) removals (>90%) were frequently reported under optimized or hybrid conditions, including electro-assisted configurations such as electrocoagulation, whereas conventional aerobic MBRs showed more variable orthophosphate removal. Operational settings that improve biological uptake or promote precipitation enhanced P removal but also intensified fouling, revealing a consistent trade-off between effluent quality and membrane service life. The evidence supports MBR-based systems as a versatile platform for meeting stringent P targets, provided that P fractions are reported explicitly and that removal mechanisms are separated from solids retention.

  • Performance assessment of a bio-electro-Fenton system for azo-dye removal from synthetic wastewater

    by Carlos Eduardo Lach, Daniele Damasceno Silveira, Tiago José Belli, Flávio Rubens Lapolli, María Ángeles Lobo-Recio


  • Treatment of azo dye-containing wastewater in a combined UASB-EMBR system: Performance evaluation and membrane fouling study

    by Tiago José Belli, Vlade Dalbosco, João Paulo Bassin, Karina Lunelli, Rayra Emanuelly da Costa, Flávio Rubens Lapolli


  • Effects of solid retention time and exposure mode to electric current on Remazol Brilliant Violet removal in an electro-membrane bioreactor

    by Tiago José Belli, João Paulo Bassin, Carlos Magno de Sousa Vidal, Maria Eliza Nagel Hassemer, Caroline Rodrigues, Flávio Rubens Lapolli

    The performance of an electrochemically assisted anoxic–oxic membrane bioreactor (A/O-eMBR) was assessed as an alternative for azo dye (Remazol Brilhant Violet (RBV)) removal from simulated textile wastewater. The A/O-eMBR was operated under three experimental conditions (runs I, II, and III), in which different solids retention time (SRT) (45 and 20 d) and exposure mode to electric current (6′ON/30′OFF and 6′ON/12′OFF) were assessed. The reactor exhibited excellent decolorization performance for all runs, with average dye removal efficiency ranging from 94.3 to 98.2%. Activity batch assays showed that the dye removal rate (DRR) decreased from 16.8 to 10.2 mg RBV L−1 h−1 when the SRT was reduced from 45 to 20 d, likely attributed to the lower biomass content under lower sludge age. At the electric current exposure mode of 6′ ON/12′OFF, a more substantial decrease of DRR to 1.5 mg RBV L−1 h−1 was noticed, suggesting a possible inhibitory effect on dye removal via biodegradation. By reducing the SRT to 20 d, a worse mixed liquor filterability condition was observed, with a membrane fouling rate (MFR) of 0.979 kPa d−1. In contrast, using the electric current exposure mode of 6′ON/12′OFF resulted in lower membrane fouling propensity, with an MFR of 0.333 kPa d−1. A more attractive cost–benefit ratio for dye removal was obtained using the exposure mode of 6′ON/30′OFF, for which the energy demand was estimated at 21.9–22.6 kWh kg dye−1 removed, almost two times lower than that observed for the mode of 6′ON/12′OFF.


  • Open Access

    Biorreator com membranas de leito móvel tratando efluente de baixa carga de indústria de produção de papel: análise de desempenho e da colmatação das membranas

    by Carlos Raphael Pedroso, Carlos Magno Vidal, Tiago José Belli, Sandro Xavier de Campos, Cleber Pinto da Silva

    O processo de biorreator com membranas tem se consolidado nos últimos anos como uma alternativa aos métodos tradicionais para o tratamento de efluentes da indústria de produção de papel. Recentemente, a introdução de material suporte nesses reatores tem contribuído para a melhoria de seu desempenho, tendo em vista a maior atividade biológica que se verifica em decorrência do desenvolvimento de biofilme. Assim, a presença da biomassa aderida confere uma capacidade adicional ao biorreator com membranas em suportar choques de cargas, bem como pode contribuir para a biodegradação de compostos potencialmente tóxicos e recalcitrantes como derivados da lignina. Desse modo, o presente trabalho teve como objetivo avaliar o desempenho de um biorreator à membrana de leito móvel operado em batelada sequencial e aplicado ao tratamento de efluente real de baixa carga oriundo da produção de papel. O reator foi avaliado quanto ao seu desempenho na remoção de demanda química de oxigênio solúvel, fenol total, cor verdadeira, compostos aromáticos (UV254nm) e lignínicos (UV280nm). Paralelamente, o reator foi avaliado quanto ao processo de colmatação das membranas, por meio do monitoramento da pressão transmembrana, da concentração de substâncias poliméricas extracelulares e produtos microbianos solúveis). Nas condições testadas, o biorreator à membrana de leito móvel operado em batelada sequencial atingiu eficiência média de remoção de 89% para demanda química de oxigênio solúvel, 39% para UV254nm, 38% para UV280nm, 57% para cor verdadeira e 73% para fenóis totais. Em relação à colmatação das membranas, as variáveis UV254nm, UV280nm e fenóis totais correlacionaram-se diretamente com o aumento da pressão transmembrana (PTM).