Frank Keith Perkins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Frank Keith Perkins has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Adam L. Friedman
Laboratory for Physical Sciences, College Park, USA
2 shared publications - Anindya Nath
Global Foundries Inc., 1000 River St, Essex Junction, VT 05452, USA
1 shared publication - Anthony Boyd
U.S. Naval Research Laboratory, 4555 Overlook Ave. SW, Washington, DC 20375, USA
1 shared publication Arthur W. Snow
U.S. Naval Research Laboratory, Washington, DC, USA
1 shared publicationAubrey T. Hanbicki
Materials Science and Technology Division, Naval Research Laboratory, 4555 Overlook Ave., S.W., Washington, DC, 20375 USA.
1 shared publicationB. T. Jonker
Naval Research Laboratory, Washington, District of Columbia 20375, United States
1 shared publication
Latest Publications
- Open Access
Electrical and Low Frequency Noise Characterization of Graphene Chemical Sensor Devices Having Different Geometries
Chemiresistive graphene sensors are promising for chemical sensing applications due to their simple device structure, high sensitivity, potential for miniaturization, low-cost, and fast response. In this work, we investigate the effect of (1) ZnO nanoparticle functionalization and (2) engineered defects onto graphene sensing channel on device resistance and low frequency electrical noise. The engineered defects of interest include 2D patterns of squares, stars, and circles and 1D patterns of slots parallel and transverse to the applied electric potential. The goal of this work is to determine which devices are best suited for chemical sensing applications. We find that, relative to pristine graphene devices, nanoparticle functionalization leads to reduced contact resistance but increased sheet resistance. In addition, functionalization lowers 1/f current noise on all but the uniform mesa device and the two devices with graphene strips parallel to carrier transport. The strongest correlations between noise and engineering defects, where normalized noise amplitude as a function of frequency f is described by a model of AN/fγ, are that γ increases with graphene area and contact area but decreases with device total perimeter, including internal features. We did not find evidence of a correlation between the scalar amplitude, AN, and the device channel geometries. In general, for a given device area, the least noise was observed on the least-etched device. These results will lead to an understanding of what features are needed to obtain the optimal device resistance and how to reduce the 1/f noise which will lead to improved sensor performance.
Open AccessElectrical and Low Frequency Noise Characterization of Graphene Chemical Sensor Devices Having Different Geometries
Chemiresistive graphene sensors are promising for chemical sensing applications due to their simple device structure, high sensitivity, potential for miniaturization, low-cost, and fast response. In this work, we investigate the effect of (1) ZnO nanoparticle functionalization and (2) engineered defects onto graphene sensing channel on device resistance and low frequency electrical noise. The engineered defects of interest include 2D patterns of squares, stars, and circles and 1D patterns of slots parallel and transverse to the applied electric potential. The goal of this work is to determine which devices are best suited for chemical sensing applications. We find that, relative to pristine graphene devices, nanoparticle functionalization leads to reduced contact resistance but increased sheet resistance. In addition, functionalization lowers 1/f current noise on all but the uniform mesa device and the two devices with graphene strips parallel to carrier transport. The strongest correlations between noise and engineering defects, where normalized noise amplitude as a function of frequency f is described by a model of AN/fγ, are that γ increases with graphene area and contact area but decreases with device total perimeter, including internal features. We did not find evidence of a correlation between the scalar amplitude, AN, and the device channel geometries. In general, for a given device area, the least noise was observed on the least-etched device. These results will lead to an understanding of what features are needed to obtain the optimal device resistance and how to reduce the 1/f noise which will lead to improved sensor performance.
- 13 May 2016
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 8 (22) , 11445-11453
Dynamics of chemical vapor sensing with MoS2using 1T/2H phase contacts/channel
Ultra-thin transition metal dichalcogenides (TMDs) films show remarkable potential for use in chemical vapor sensing devices. Electronic devices fabricated from TMD films are inexpensive, inherently flexible, low-power, amenable to industrial-scale processing because of emergent growth techniques, and have shown high sensitivity and selectivity to electron donor analyte molecules important for explosives and nerve gas detection. However, for devices reported to date, the conductance response to chemical vapors is dominated by Schottky contacts, to the detriment of the sensitivity, selectivity, recovery, and obscuring their intrinsic behavior. Here, we use contact engineering to transition the contacts in a MoS2 FET-based chemical vapor sensor to the 1T conducting phase, while leaving the channel in the 2H semiconducting state, and thus providing Ohmic contacts to the film. We demonstrate that the resultant sensors have much improved electrical characteristics, are more selective, and recover fully after chemical vapor exposure—all major enhancements to previously MoS2 sensor devices. We identify labile nitrogen-containing electron donors as the primary species that generate a response in MoS2, and we study the dynamics of the sensing reactions, identifying two possible qualitative models for the chemical sensing reaction.
- 13 May 2016
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 8 (22) , 11445-11453
Dynamics of chemical vapor sensing with MoS2using 1T/2H phase contacts/channel
Ultra-thin transition metal dichalcogenides (TMDs) films show remarkable potential for use in chemical vapor sensing devices. Electronic devices fabricated from TMD films are inexpensive, inherently flexible, low-power, amenable to industrial-scale processing because of emergent growth techniques, and have shown high sensitivity and selectivity to electron donor analyte molecules important for explosives and nerve gas detection. However, for devices reported to date, the conductance response to chemical vapors is dominated by Schottky contacts, to the detriment of the sensitivity, selectivity, recovery, and obscuring their intrinsic behavior. Here, we use contact engineering to transition the contacts in a MoS2 FET-based chemical vapor sensor to the 1T conducting phase, while leaving the channel in the 2H semiconducting state, and thus providing Ohmic contacts to the film. We demonstrate that the resultant sensors have much improved electrical characteristics, are more selective, and recover fully after chemical vapor exposure—all major enhancements to previously MoS2 sensor devices. We identify labile nitrogen-containing electron donors as the primary species that generate a response in MoS2, and we study the dynamics of the sensing reactions, identifying two possible qualitative models for the chemical sensing reaction.
- 23 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 15 (3) , 1301-1320
Disordered Nanomaterials for Chemielectric Vapor Sensing: A Review
Although robust chemical vapor detection by chemielectric point sensors remains as a largely unmet challenge at present, the best performance to date and the most likely avenue for future progress is with sensor designs in which the transductive element is a disordered nanostructured material. We here review the evidence for this claim, with illustrations drawn from recent work on sensors made from gold nanoparticles, carbon nanotubes, and reduced graphene oxide nanoplatelets. These examples can be regarded as being prototypical of disordered nanostructured films formed of primitive objects that are nanoscopic in 3-D, 2-D, and 1-D, respectively.
- 23 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 15 (3) , 1301-1320
Disordered Nanomaterials for Chemielectric Vapor Sensing: A Review
Although robust chemical vapor detection by chemielectric point sensors remains as a largely unmet challenge at present, the best performance to date and the most likely avenue for future progress is with sensor designs in which the transductive element is a disordered nanostructured material. We here review the evidence for this claim, with illustrations drawn from recent work on sensors made from gold nanoparticles, carbon nanotubes, and reduced graphene oxide nanoplatelets. These examples can be regarded as being prototypical of disordered nanostructured films formed of primitive objects that are nanoscopic in 3-D, 2-D, and 1-D, respectively.
- Top Cited Papers
- 22 January 2013
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 13 (2) , 668-673
Chemical Vapor Sensing with Monolayer MoS2
Two-dimensional materials such as graphene show great potential for future nanoscale electronic devices. The high surface-to-volume ratio is a natural asset for applications such as chemical sensing, where perturbations to the surface resulting in charge redistribution are readily manifested in the transport characteristics. Here we show that single monolayer MoS2 functions effectively as a chemical sensor, exhibiting highly selective reactivity to a range of analytes and providing sensitive transduction of transient surface physisorption events to the conductance of the monolayer channel. We find strong response upon exposure to triethylamine, a decomposition product of the V-series nerve gas agents. We discuss these results in the context of analyte/sensor interaction in which the analyte serves as either an electron donor or acceptor, producing a temporary charge perturbation of the sensor material. We find highly selective response to electron donors and little response to electron acceptors, consistent with the weak n-type character of our MoS2. The MoS2 sensor exhibits a much higher selectivity than carbon nanotube-based sensors.
- 22 January 2013
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 13 (2) , 668-673
Top Cited PapersChemical Vapor Sensing with Monolayer MoS2
Two-dimensional materials such as graphene show great potential for future nanoscale electronic devices. The high surface-to-volume ratio is a natural asset for applications such as chemical sensing, where perturbations to the surface resulting in charge redistribution are readily manifested in the transport characteristics. Here we show that single monolayer MoS2 functions effectively as a chemical sensor, exhibiting highly selective reactivity to a range of analytes and providing sensitive transduction of transient surface physisorption events to the conductance of the monolayer channel. We find strong response upon exposure to triethylamine, a decomposition product of the V-series nerve gas agents. We discuss these results in the context of analyte/sensor interaction in which the analyte serves as either an electron donor or acceptor, producing a temporary charge perturbation of the sensor material. We find highly selective response to electron donors and little response to electron acceptors, consistent with the weak n-type character of our MoS2. The MoS2 sensor exhibits a much higher selectivity than carbon nanotube-based sensors.