FCFederico Conrotto

Federico Conrotto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Federico Conrotto has a total of 211 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Navigating myocardial infarction in the oldest: Aging hearts, new challenges

    by Federico Conrotto, Francesco Bruno

    Despite important advancements in interventional cardiology, myocardial infarction (MI) remains a formidable challenge in modern medicine, particularly among the elderly, who often

  • Medina 0.0.1. bifurcations: Let's keep it simple

    by Federico Conrotto, Francesco Bruno

  • Open Access

    Acute Modification of Hemodynamic Forces in Patients with Severe Aortic Stenosis after Transcatheter Aortic Valve Implantation

    by Alessandro Vairo, Lorenzo Zaccaro, Andrea Ballatore, Lorenzo Airale, Fabrizio D’ascenzo, Gianluca Alunni, Federico Conrotto, Luca Scudeler, Daniela Mascaretti, Davide Miccoli, et al.

    Transcatheter aortic valve implantation (TAVI) is the established first-line treatment for patient with severe aortic stenosis not suitable for surgery. Echocardiographic evaluation of hemodynamic forces (HDFs) is a growing field, holding the potential to early predict improvement in LV function. A prospective observational study was conducted. Transthoracic echocardiography was performed before and after TAVI. HDFs were analyzed along with traditional left ventricular (LV) function parameters. Twenty-five consecutive patients undergoing TAVI were enrolled: mean age 83 ± 5 years, 74.5% male, mean LV Ejection Fraction (LVEF) at baseline 57 ± 8%. Post-TAVI echocardiographic evaluation was performed 2.4 ± 1.06 days after the procedure. HDF amplitude parameters improved significantly after the procedure: LV Longitudinal Forces (LF) apex-base [mean difference (MD) 1.79%; 95% CI 1.07–2.5; p-value < 0.001]; LV systolic LF apex-base (MD 2.6%; 95% CI 1.57–3.7; p-value < 0.001); LV impulse (LVim) apex-base (MD 2.9%; 95% CI 1.48–4.3; p-value < 0.001). Similarly, HDFs orientation parameters improved: LVLF angle (MD 1.5°; 95% CI 0.07–2.9; p-value = 0.041); LVim angle (MD 2.16°; 95% CI 0.76–3.56; p-value = 0.004). Conversely, global longitudinal strain and LVEF did not show any significant difference before and after the procedure. Echocardiographic analysis of HDFs could help differentiate patients with LV function recovery after TAVI from patients with persistent hemodynamic dysfunction.


  • Open Access

    Prediction of All-Cause Mortality Following Percutaneous Coronary Intervention in Bifurcation Lesions Using Machine Learning Algorithms

    by Jacopo Burrello, Guglielmo Gallone, Alessio Burrello, Daniele Jahier Pagliari, Eline H. Ploumen, Mario Iannaccone, Leonardo De Luca, Paolo Zocca, Giuseppe Patti, Enrico Cerrato, et al.

    Stratifying prognosis following coronary bifurcation percutaneous coronary intervention (PCI) is an unmet clinical need that may be fulfilled through the adoption of machine learning (ML) algorithms to refine outcome predictions. We sought to develop an ML-based risk stratification model built on clinical, anatomical, and procedural features to predict all-cause mortality following contemporary bifurcation PCI. Multiple ML models to predict all-cause mortality were tested on a cohort of 2393 patients (training, n = 1795; internal validation, n = 598) undergoing bifurcation PCI with contemporary stents from the real-world RAIN registry. Twenty-five commonly available patient-/lesion-related features were selected to train ML models. The best model was validated in an external cohort of 1701 patients undergoing bifurcation PCI from the DUTCH PEERS and BIO-RESORT trial cohorts. At ROC curves, the AUC for the prediction of 2-year mortality was 0.79 (0.74–0.83) in the overall population, 0.74 (0.62–0.85) at internal validation and 0.71 (0.62–0.79) at external validation. Performance at risk ranking analysis, k-center cross-validation, and continual learning confirmed the generalizability of the models, also available as an online interface. The RAIN-ML prediction model represents the first tool combining clinical, anatomical, and procedural features to predict all-cause mortality among patients undergoing contemporary bifurcation PCI with reliable performance.


  • TAVI and risk scores: Looking back while moving forward

    by Federico Conrotto, Francesco Bruno, Fabrizio D’ascenzo


  • Open Access

    Transcarotid access route: a first-choice option for nontransfemoral transcatheter aortic valve implantation

    by Federico Conrotto, Francesco Bruno, Fabrizio D’aScenzo

    DOI: 10.33963/KP.15765, Published online: January 25, 2021, Authors: Federico Conrotto, Francesco Bruno, Fabrizio D’Ascenzo

  • Is oral anticoagulation effective in preventing transcatheter aortic valve implantation failure? A propensity matched analysis of the Italian Transcatheter balloon-Expandable valve Registry study

    by Federico Conrotto, Fabrizio D’aScenzo, Matteo Bianco, Stefano Salizzoni, Augusto D’oNofrio, Flavio Ribichini, Giuseppe Tarantini, Maurizio D’aMico, Claudio Moretti, Mauro Rinaldi

    Background: Early hypo-attenuated leaflet thickening after transcatheter aortic valve implantation (TAVI) has been recently described presumably reflecting thrombus apposition. Although its clinical relevance is still unknown, oral anticoagulant therapy (OAT) led to almost complete resolution. Methods: The retrospecitve Italian Transcatheter balloon-Expandable valve registry that included all patients undergoing balloon-expandable TAVI in 33 Italian centers. Patients discharged after TAVI with aspirin alone were compared with those assuming aspirin and OAT before and after propensity score with matching. Prosthetic heart valve dysfunction at follow-up was the primary end point. All-cause death, cardiovascular death, bleeding, vascular complications and cerebrovascular accidents at 30 days and at follow-up were the secondary ones. Results: Among the 1904 patients enrolled in the Italian Transcatheter balloon-Expandable valve registry, 716 patients on OAT and aspirin or aspirin alone were identified and analyzed: 555 were on aspirin alone and 161 on OAT and aspirin. The median follow-up was 44.0 ± 12 months. After matching, risk of prosthetic valve dysfunction at follow-up did not differ between the two groups: 3.1% in patients treated with aspirin alone vs. 1.9% in those treated with OAT and aspirin, (P = 0.72). Nevertheless patients treated with aspirin alone at follow-up had a significantly lower risk of death (21 vs. 33%, P = 0.03) and major bleeding (4 vs. 14%, P = 0.04) with a similar rate of stroke/transient ischemic attack (TIA) (1.2 vs. 3.1%, P = 0.45). At 30 days rates of Valve Academic Research Consortium death were similar in both groups (0.6 vs. 3.7%, P = 0.12) with higher risk of life threatening bleeding and minor vascular complications in patients on OAT and aspirin. Conclusion: After TAVI with Edwards Sapien valve OAT did not reduce the incidence of valve dysfunction and stroke but was responsible for mortality and bleeding increases.


  • Transcatheter Aortic Valve Implantation in Patients With Advanced Chronic Kidney Disease

    by Federico Conrotto, Stefano Salizzoni, Alessandro Andreis, Fabrizio D'AScenzo, Augusto D'ONofrio, Marco Agrifoglio, Alaide Chieffo, Antonio Colombo, Filippo Rapetto, Francesco Santini, et al.


  • Outcomes of patients with low‐pressure aortic gradient undergoing transcatheter aortic valve implantation

    by Federico Conrotto, Fabrizio D'AScenzo, Maurizio D'AMico, Claudio Moretti, Marco Pavani, Paolo Scacciatella, Pierluigi Omedè, Antonio Montefusco, Giuseppe Biondi‐Zoccai, Fiorenzo Gaita, et al.

    Background: The risk/benefit balance of transcatheter aortic valve implantation (TAVI) in patients with low‐gradient aortic stenosis (LGAS) remains to be well defined. Aim of the study was to investigate the impact of LGAS in patients undergoing TAVI.Methods: Medline, Cochrane Library, and Scopus were searched for articles reporting outcome of patients with LGAS undergoing TAVI. The primary endpoint was 12‐months all‐cause mortality and the secondary endpoint was 30‐day all‐cause mortality. Using event‐rates as dependent variable, a meta‐regression was performed to test for interaction between baseline clinical features (age, gender, diabetes mellitus, coronary artery disease, left ventricular ejection fraction (LVEF) and type of implanted valve) and transaortic gradient for the primary endpoint.Results: Eight studies with a total of 12,589 patients were included. Almost one‐third of the patients presented with LGAS (27.3%: 24.4–29.2). Median LVEF was 48% in patients with LGAS and 56% in patients with high‐gradient AS. Patients with LGAS were more likely to have diabetes mellitus, previous coronary artery disease, higher mean Logistic EuroSCORE, and lower EF. At 12 (12–16.6) months, low transaortic gradient emerged as independently associated with all‐cause death, both if evaluated as a dichotomous and continuous value (respectively OR 1.17; 1.11–1.23 and OR 1.02; 1–1.04, all CI 95%). Clinical variables, including EF did not affect this result.Conclusions: In a population of TAVI patients, LGAS appears to be independently related to dismal prognosis.


  • Open Access

    Predictive ability of the CHADS2and CHA2DS2-VASc scores for stroke after transcatheter aortic balloon-expandable valve implantation: an Italian Transcatheter Balloon-Expandable Valve Implantation Registry (ITER) sub-analysis

    by Federico Conrotto, Fabrizio D'Ascenzo, Augusto D'Onofrio, Marco Agrifoglio, Alaide Chieffo, Micaela Cioni, Tommaso Regesta, Giuseppe Tarantini, Davide Gabbieri, Francesco Saia, et al.

    Stroke incidence after transcatheter aortic valve implantation (TAVI) still represents a concern. This multicentre study aimed at investigating the hypothesis that CHADS2 and CHA2DS2-VASc scores may be used to predict perioperative stroke after TAVI. The Italian Transcatheter Balloon-Expandable Valve Implantation Registry (ITER) is a multicentre, prospective registry of patients undergoing balloon-expandable TAVI using Edwards Sapien and Sapien XT prosthesis between 2007 and 2012. The primary end-point of this study was the 30-day stroke rate. Secondary safety end-points were all the major adverse events based on Valve Academic Research Consortium (VARC-2) criteria. One thousand nine hundred and four patients were enrolled in the registry. Mean age was 81.6 ± 6.2 years and 1147 (60.2%) patients were female; mean CHADS2 and CHA2DS2-VASc scores were 2.2 ± 0.8 and 4.4 ± 1.1, respectively. Fifty-four (2.8%) patients had a stroke within 30 days. At multivariable logistic regression analysis, CHA2DS2-VASc (OR: 1.35, 95% CI: 1.03–1.78; P = 0.031) and previous cardiac surgery (OR: 1.96, 95% CI: 1.06–3.6; P = 0.033) but not CHADS2 (OR: 1.05, 95% CI: 0.76–1.44; P = 0.77) were found to be independent predictors of in-hospital stroke. A CHA2DS2-VASc score ≥5 was strongly related to the occurrence of in-hospital stroke (OR: 2.51, 95% CI: 1.38–4.57; P= 0.001). However, CHA2DS2-VASc score showed only poor accuracy for in-hospital stroke with a trend for better accuracy when compared with CHADS2 score (area under the curve: 0.61, 95% CI: 0.59–0.63 vs 0.51; 95% CI: 0.49–0.54, respectively, P = 0.092). In TAVI patients, CHA2DS2-VASc provided a strong correlation for in-hospital stroke but with low accuracy. Dedicated scores to properly tailor procedures and preventive strategies are needed.