Je-Hoon Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Je-Hoon Lee has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Salaki Reynaldo Joshua
Informatics Engineering, Faculty of Engineering, Sam Ratulangi University, Manado, Indonesia
4 shared publications - Wasim Abbas
Department of Electronics, Information and Communication Engineering, Kangwon National University, Samcheok-si 25913, Republic of Korea
3 shared publications - Jai-Chang Park
Robot SW R&D Team, Angel Robotics Co., Seoul 04798, Korea
2 shared publications MinSung Yoon
KITECH, Kangwon National University, 1 Joongang-ro, Samcheock, Gangwon 245-711, South Korea
2 shared publicationsSang-Choon Kim
2 shared publications- Seong-Kun Kim
Department of Liberal Studies Kangwon National University 25913 Samcheok Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 19 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (20) , 10351
Analysis of Journal-Bearing Wear Damage Caused by Residual Metallic Particles in the Lubrication System of an Ultra-Supercritical Steam Turbine
Ultra-supercritical (USC) steam turbines are high-efficiency, large-capacity power-generation systems that generally operate under steam conditions exceeding approximately 600 °C and 25 MPa. Journal bearings are critical mechanical components that support rotor loads and maintain the stable position of the rotating shaft. In this study, an actual high-vibration trip event in the journal-bearing lubrication system of a 1050 MW USC steam turbine was investigated by integrating operational data, surface-damage characteristics, recovered foreign particles, material properties, and particle–film hydrodynamic screening. During the event, the T8 journal vibration displacement increased from approximately 62.5 to 225 μm, exceeding the 220 μm trip threshold, and the T8 bearing-metal temperature increased to approximately 118–120 °C near 500 rpm during coast-down. The maximum abrasive-wear depths measured at T5, T7, T8, and T9 were 0.79, 0.73, 0.71, and 0.55 mm, respectively. The expanded descriptive dataset comprised 30 representative recovered particles, with measured sizes ranging from approximately 0.08 to 2.5 mm and a descriptive mean of approximately 0.71 mm; the particles included Fe-based contaminants and Sn-bearing secondary wear debris. The bearing metal had a hardness of approximately 18 HV, whereas the recovered hard particles exhibited substantially higher hardness. Particle–film interactions at bearings T5, T7, and T8 were quantitatively evaluated as functions of rotational speed, lubricant viscosity, and particle size using particle response time, radius-based and local-shear-based nominal Stokes numbers and particle-to-film geometric relationships. Under identical rotational speed, lubricant viscosity, and particle-size conditions, the radius-based nominal Stokes number was identical among the three bearings, whereas the local-shear Stokes number varied with bearing geometry and maximum oil-film thickness. For the 200 μm reference particle at 3600 rpm, the T8 radius-based nominal Stokes number was 0.1359, whereas the local-shear Stokes number was 154.58, demonstrating the strong dependence of particle response on the selected fluid time scale. The observed directional wear, particle embedment and pull-out traces, hardness contrast, and conditional particle–film analysis are consistent with a particle-mediated three-body abrasive-wear mechanism. These findings indicate that particle behavior cannot be assessed from nominal particle size alone and that prevention of particle ingress and retention requires life-cycle contamination control during fabrication, installation, flushing, and commissioning.
- 19 October 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (20) , 10351
Open AccessAnalysis of Journal-Bearing Wear Damage Caused by Residual Metallic Particles in the Lubrication System of an Ultra-Supercritical Steam Turbine
Ultra-supercritical (USC) steam turbines are high-efficiency, large-capacity power-generation systems that generally operate under steam conditions exceeding approximately 600 °C and 25 MPa. Journal bearings are critical mechanical components that support rotor loads and maintain the stable position of the rotating shaft. In this study, an actual high-vibration trip event in the journal-bearing lubrication system of a 1050 MW USC steam turbine was investigated by integrating operational data, surface-damage characteristics, recovered foreign particles, material properties, and particle–film hydrodynamic screening. During the event, the T8 journal vibration displacement increased from approximately 62.5 to 225 μm, exceeding the 220 μm trip threshold, and the T8 bearing-metal temperature increased to approximately 118–120 °C near 500 rpm during coast-down. The maximum abrasive-wear depths measured at T5, T7, T8, and T9 were 0.79, 0.73, 0.71, and 0.55 mm, respectively. The expanded descriptive dataset comprised 30 representative recovered particles, with measured sizes ranging from approximately 0.08 to 2.5 mm and a descriptive mean of approximately 0.71 mm; the particles included Fe-based contaminants and Sn-bearing secondary wear debris. The bearing metal had a hardness of approximately 18 HV, whereas the recovered hard particles exhibited substantially higher hardness. Particle–film interactions at bearings T5, T7, and T8 were quantitatively evaluated as functions of rotational speed, lubricant viscosity, and particle size using particle response time, radius-based and local-shear-based nominal Stokes numbers and particle-to-film geometric relationships. Under identical rotational speed, lubricant viscosity, and particle-size conditions, the radius-based nominal Stokes number was identical among the three bearings, whereas the local-shear Stokes number varied with bearing geometry and maximum oil-film thickness. For the 200 μm reference particle at 3600 rpm, the T8 radius-based nominal Stokes number was 0.1359, whereas the local-shear Stokes number was 154.58, demonstrating the strong dependence of particle response on the selected fluid time scale. The observed directional wear, particle embedment and pull-out traces, hardness contrast, and conditional particle–film analysis are consistent with a particle-mediated three-body abrasive-wear mechanism. These findings indicate that particle behavior cannot be assessed from nominal particle size alone and that prevention of particle ingress and retention requires life-cycle contamination control during fabrication, installation, flushing, and commissioning.
- Open Access
An End-to-End GSM/SMS Encrypted Approach for Smartphone Employing Advanced Encryption Standard(AES)
Encryption is crucial for securing sensitive data during transmission over networks. Various encryption techniques exist, such as AES, DES, and RC4, with AES being the most renowned algorithm. We proposed methodology that enables users to encrypt text messages for secure transmission over cellular networks. This approach utilizes the AES algorithm following the proposed protocols for encryption and decryption, ensuring fast and reliable data protection. This approach ensures secure text encryption and enables users to enter messages that are encrypted using a key at the sender's end and decrypted at the recipient's end, which is compatible with any Android device. SMS are encrypted with the AES algorithm, making them resistant to brute-force attempts. As SMS has become a popular form of communication, protecting personal data, email alerts, banking details, and transactions information. It addresses security concerns by encrypting messages using AES and cryptographic techniques, providing an effective solution for protecting sensitive data during SMS exchanges.
Open AccessAn End-to-End GSM/SMS Encrypted Approach for Smartphone Employing Advanced Encryption Standard(AES)
Encryption is crucial for securing sensitive data during transmission over networks. Various encryption techniques exist, such as AES, DES, and RC4, with AES being the most renowned algorithm. We proposed methodology that enables users to encrypt text messages for secure transmission over cellular networks. This approach utilizes the AES algorithm following the proposed protocols for encryption and decryption, ensuring fast and reliable data protection. This approach ensures secure text encryption and enables users to enter messages that are encrypted using a key at the sender's end and decrypted at the recipient's end, which is compatible with any Android device. SMS are encrypted with the AES algorithm, making them resistant to brute-force attempts. As SMS has become a popular form of communication, protecting personal data, email alerts, banking details, and transactions information. It addresses security concerns by encrypting messages using AES and cryptographic techniques, providing an effective solution for protecting sensitive data during SMS exchanges.
- Open Access
Health to Eat: A Smart Plate with Food Recognition, Classification, and Weight Measurement for Type-2 Diabetic Mellitus Patients’ Nutrition Control
The management of type 2 diabetes mellitus (T2DM) is generally not only focused on pharmacological therapy. Medical nutrition therapy is often forgotten by patients for several reasons, such as difficulty determining the right nutritional pattern for themselves, regulating their daily nutritional patterns, or even not heeding nutritional diet recommendations given by doctors. Management of nutritional therapy is one of the important efforts that can be made by diabetic patients to prevent an increase in the complexity of the disease. Setting a diet with proper nutrition will help patients manage a healthy diet. The development of Smart Plate Health to Eat is a technological innovation that helps patients and users know the type of food, weight, and nutrients contained in certain foods. This study involved 50 types of food with a total of 30,800 foods using the YOLOv5s algorithm, where the identification, measurement of weight, and nutrition of food were investigated using a Chenbo load cell weight sensor (1 kg), an HX711 weight weighing A/D module pressure sensor, and an IMX219-160 camera module (waveshare). The results of this study showed good identification accuracy in the analysis of four types of food: rice (58%), braised quail eggs in soy sauce (60%), spicy beef soup (62%), and dried radish (31%), with accuracy for weight and nutrition (100%).
Open AccessHealth to Eat: A Smart Plate with Food Recognition, Classification, and Weight Measurement for Type-2 Diabetic Mellitus Patients’ Nutrition Control
The management of type 2 diabetes mellitus (T2DM) is generally not only focused on pharmacological therapy. Medical nutrition therapy is often forgotten by patients for several reasons, such as difficulty determining the right nutritional pattern for themselves, regulating their daily nutritional patterns, or even not heeding nutritional diet recommendations given by doctors. Management of nutritional therapy is one of the important efforts that can be made by diabetic patients to prevent an increase in the complexity of the disease. Setting a diet with proper nutrition will help patients manage a healthy diet. The development of Smart Plate Health to Eat is a technological innovation that helps patients and users know the type of food, weight, and nutrients contained in certain foods. This study involved 50 types of food with a total of 30,800 foods using the YOLOv5s algorithm, where the identification, measurement of weight, and nutrition of food were investigated using a Chenbo load cell weight sensor (1 kg), an HX711 weight weighing A/D module pressure sensor, and an IMX219-160 camera module (waveshare). The results of this study showed good identification accuracy in the analysis of four types of food: rice (58%), braised quail eggs in soy sauce (60%), spicy beef soup (62%), and dried radish (31%), with accuracy for weight and nutrition (100%).
- Open Access
- 17 January 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (3) , 1251
Trust Components: An Analysis in The Development of Type 2 Diabetic Mellitus Mobile Application
Trust in information and communication technology devices is an important factor, considering the role of technology in carrying out supporting tasks in everyday human activities. The level of trust in technology will influence its application and adoption. Recognizing the importance of trust in technology, researchers in this study will examine trust components for the development of a type 2 diabetes mobile application. The results of this study resulted in three major focuses, namely the application design (consisting of architecture), UI design, and evaluation of trust factors of the application: functionality, ease of use, usefulness, security and privacy, and cost. This analysis of trust components will be useful for the application or adoption by users of a type 2 diabetes mellitus mobile application so that users will trust the application both in terms of functionality and the generated information.
- 17 January 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (3) , 1251
Open AccessTrust Components: An Analysis in The Development of Type 2 Diabetic Mellitus Mobile Application
Trust in information and communication technology devices is an important factor, considering the role of technology in carrying out supporting tasks in everyday human activities. The level of trust in technology will influence its application and adoption. Recognizing the importance of trust in technology, researchers in this study will examine trust components for the development of a type 2 diabetes mobile application. The results of this study resulted in three major focuses, namely the application design (consisting of architecture), UI design, and evaluation of trust factors of the application: functionality, ease of use, usefulness, security and privacy, and cost. This analysis of trust components will be useful for the application or adoption by users of a type 2 diabetes mellitus mobile application so that users will trust the application both in terms of functionality and the generated information.
- Open Access
- 20 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 13 (1) , 8
M-Healthcare Model: An Architecture for a Type 2 Diabetes Mellitus Mobile Application
Type 2 diabetes mellitus (T2DM) is a metabolic disorder wherein the patients require DM management to keep their blood glucose under proper and regular control. Diabetes mellitus can be managed with the help of technologies, one of which is mobile health. Mobile health is an innovation in telemedicine that utilizes gadgets as a medium to access digitally based health information and services by utilizing electronic devices connected to the Internet. Mobile health services are distinguished based on interactions between users and medical personnel; namely, interactive and non-interactive services. The developed application can integrate Android mobile application software with supporting hardware, such as a glucometer, a wearable band, a heart rate sensor, a treadmill, and an exercise bike. The provided features in this mobile application include the monitoring of medication, food intake, exercise, and sleep. This study’s goal was to create a mobile application architecture for type 2 diabetes mellitus mobile applications. This research focused on developing an architecture for mobile diabetes applications, a hardware block diagram design, and an architecture of sensors for a type 2 diabetes mellitus mobile application.
- 20 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 13 (1) , 8
Open AccessM-Healthcare Model: An Architecture for a Type 2 Diabetes Mellitus Mobile Application
Type 2 diabetes mellitus (T2DM) is a metabolic disorder wherein the patients require DM management to keep their blood glucose under proper and regular control. Diabetes mellitus can be managed with the help of technologies, one of which is mobile health. Mobile health is an innovation in telemedicine that utilizes gadgets as a medium to access digitally based health information and services by utilizing electronic devices connected to the Internet. Mobile health services are distinguished based on interactions between users and medical personnel; namely, interactive and non-interactive services. The developed application can integrate Android mobile application software with supporting hardware, such as a glucometer, a wearable band, a heart rate sensor, a treadmill, and an exercise bike. The provided features in this mobile application include the monitoring of medication, food intake, exercise, and sleep. This study’s goal was to create a mobile application architecture for type 2 diabetes mellitus mobile applications. This research focused on developing an architecture for mobile diabetes applications, a hardware block diagram design, and an architecture of sensors for a type 2 diabetes mellitus mobile application.
- Open Access
- 29 July 2021
- Published by MDPI AG in Electronics
- Vol. 10 (15) , 1820
Therapeutic Exercise Platform for Type-2 Diabetic Mellitus
Exercise enables continuous glycemic control for diabetic patients, and it is effective in preventing diabetic complications and maintaining emotional stability. However, it is difficult for diabetic patients to know the appropriate intensity and duration of exercise. Excessive exercise causes sudden hypoglycemia, and patients avoid therapeutic exercise or perform it conservatively owing to the repeated hypoglycemia symptoms. In this paper, we propose a new therapeutic exercise platform that supports type 2 diabetes patients to exercise regularly according to the exercise prescription received from the hospital. The proposed platform includes the following three significant contributions. First, we develop a hardware platform that automatically tracks and records all aerobic exercise performed by a patient indoors or outdoors using a wearable band and aerobic exercise equipment. Second, we devise a patient-specific exercise stress test to know whether the patient is exercising according to his or her usual exercise regimen. Finally, we develop a mobile application that informs patients in real-time whether they are exercising appropriately for their exercise regimen each time they exercise. For platform evaluation and future improvement, we received satisfaction ratings and functional improvements through a questionnaire survey on 10 type 2 diabetes patients and 10 persons without a diabetes diagnosis who had used the proposed platform for more than 3 months. Most users were (1) satisfied with automatic exercise recording, and (2) exercise time increased. Diabetics reported that their fasting blood glucose was dropped, and they were more motivated to exercise. These results prove that exercise must be combined with medication for blood glucose management in chronic diabetic patients. The proposed platform can be helpful for patients to continue their daily exercise according to their exercise prescription.
- 29 July 2021
- Published by MDPI AG in Electronics
- Vol. 10 (15) , 1820
Open AccessTherapeutic Exercise Platform for Type-2 Diabetic Mellitus
Exercise enables continuous glycemic control for diabetic patients, and it is effective in preventing diabetic complications and maintaining emotional stability. However, it is difficult for diabetic patients to know the appropriate intensity and duration of exercise. Excessive exercise causes sudden hypoglycemia, and patients avoid therapeutic exercise or perform it conservatively owing to the repeated hypoglycemia symptoms. In this paper, we propose a new therapeutic exercise platform that supports type 2 diabetes patients to exercise regularly according to the exercise prescription received from the hospital. The proposed platform includes the following three significant contributions. First, we develop a hardware platform that automatically tracks and records all aerobic exercise performed by a patient indoors or outdoors using a wearable band and aerobic exercise equipment. Second, we devise a patient-specific exercise stress test to know whether the patient is exercising according to his or her usual exercise regimen. Finally, we develop a mobile application that informs patients in real-time whether they are exercising appropriately for their exercise regimen each time they exercise. For platform evaluation and future improvement, we received satisfaction ratings and functional improvements through a questionnaire survey on 10 type 2 diabetes patients and 10 persons without a diabetes diagnosis who had used the proposed platform for more than 3 months. Most users were (1) satisfied with automatic exercise recording, and (2) exercise time increased. Diabetics reported that their fasting blood glucose was dropped, and they were more motivated to exercise. These results prove that exercise must be combined with medication for blood glucose management in chronic diabetic patients. The proposed platform can be helpful for patients to continue their daily exercise according to their exercise prescription.
- Open Access
- 22 March 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (6) , 2818
Improvement of Torque Performance and Energy Density of PM-Type Vernier Motor Utilizing Saddle Coil and Salient Pole
In electric motors, the use of rare-earth magnets has been increasing rapidly. A stronger magnet force of the magnet enables the motor’s higher performance, resulting in the most high-performance motors generally using rare-earth magnets. However, these magnets have two crucial disadvantages: the potential restrictions on the supply of rare-earth magnetic materials and the sharp fluctuation in price. Thus, many recent researches focus on developing high-performance electric motors and reducing the use of critical rare-earth magnets. By increasing the torque density of the motor, we can reduce the use of permanent magnets. Focusing on this point, and we presented a double half permanent magnet (DHPM)-type vernier motor. This paper proposed a new saddle coil permanent magnet vernier motor with improved performance compared to its predecessor. The main feature of the proposed motor is that the permanent magnet and coil in the stator of a DHPM-type vernier motor is replaced by salient poles and saddle coils, respectively. We also investigate its characteristics through various simulations.
- 22 March 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (6) , 2818
Open AccessImprovement of Torque Performance and Energy Density of PM-Type Vernier Motor Utilizing Saddle Coil and Salient Pole
In electric motors, the use of rare-earth magnets has been increasing rapidly. A stronger magnet force of the magnet enables the motor’s higher performance, resulting in the most high-performance motors generally using rare-earth magnets. However, these magnets have two crucial disadvantages: the potential restrictions on the supply of rare-earth magnetic materials and the sharp fluctuation in price. Thus, many recent researches focus on developing high-performance electric motors and reducing the use of critical rare-earth magnets. By increasing the torque density of the motor, we can reduce the use of permanent magnets. Focusing on this point, and we presented a double half permanent magnet (DHPM)-type vernier motor. This paper proposed a new saddle coil permanent magnet vernier motor with improved performance compared to its predecessor. The main feature of the proposed motor is that the permanent magnet and coil in the stator of a DHPM-type vernier motor is replaced by salient poles and saddle coils, respectively. We also investigate its characteristics through various simulations.
- Open Access
- 24 February 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (5) , 2006
Self-Care IoT Platform for Diabetic Mellitus
Diabetes mellitus is a severe chronic disease, and the number of patients has increased. To manage blood glucose levels, patients should frequently measure their blood glucose and analyze which lifestyle habits affect blood glucose levels. However, it is hard to record and analyze the relationship between their blood glucose levels and lifestyle. The internet of things (IoT) is useful to interconnect, monitor, obtain, and process data between various devices used in everyday life to fulfill a common objective. This paper proposes an intelligent self-care platform using IoT technology that helps patients with chronic diabetes manage their blood glucose levels in their target range. In particular, we developed various devices called the self-care IoT pack. It consists of five different types of devices to obtain blood glucose levels, physical activities, food intake, medication, sleeping, and so on. They can collect blood glucose levels with lifestyles that automatically impact the patient’s blood glucose level. We also devised a self-care application to display and analyze the data obtained from the IoT pack. Consequently, the proposed self-care IoT platform collects the blood glucose levels and the lifestyles without any burden of record. By reviewing the accumulated information, the patients can find bad habits in blood glucose management and improve their lifestyle.
- 24 February 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (5) , 2006
Open AccessSelf-Care IoT Platform for Diabetic Mellitus
Diabetes mellitus is a severe chronic disease, and the number of patients has increased. To manage blood glucose levels, patients should frequently measure their blood glucose and analyze which lifestyle habits affect blood glucose levels. However, it is hard to record and analyze the relationship between their blood glucose levels and lifestyle. The internet of things (IoT) is useful to interconnect, monitor, obtain, and process data between various devices used in everyday life to fulfill a common objective. This paper proposes an intelligent self-care platform using IoT technology that helps patients with chronic diabetes manage their blood glucose levels in their target range. In particular, we developed various devices called the self-care IoT pack. It consists of five different types of devices to obtain blood glucose levels, physical activities, food intake, medication, sleeping, and so on. They can collect blood glucose levels with lifestyles that automatically impact the patient’s blood glucose level. We also devised a self-care application to display and analyze the data obtained from the IoT pack. Consequently, the proposed self-care IoT platform collects the blood glucose levels and the lifestyles without any burden of record. By reviewing the accumulated information, the patients can find bad habits in blood glucose management and improve their lifestyle.
- 28 February 2014
- Published by Korea Institute of Information Security and Cryptology in Journal of the Korea Institute of Information Security and Cryptology
- Vol. 24 (1) , 51-58
A Segmented Leap-Ahead LFSR Pseudo-Random Number Generator
- 28 February 2014
- Published by Korea Institute of Information Security and Cryptology in Journal of the Korea Institute of Information Security and Cryptology
- Vol. 24 (1) , 51-58
A Segmented Leap-Ahead LFSR Pseudo-Random Number Generator
- 31 July 2013
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 22 (4) , 268-275
Wake-up Algorithm of Wireless Sensor Node Using Geometric Probability
- 31 July 2013
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 22 (4) , 268-275
Wake-up Algorithm of Wireless Sensor Node Using Geometric Probability