Josemberg Marins Campos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Josemberg Marins Campos has a total of 109 co-authors. Here are the top co-authors by number of shared publications:
- Manoel Galvao Neto
Orlando Health, Florida, United States
15 shared publications - Almino Cardoso Ramos
Gastro-Obeso-Center
6 shared publications Álvaro A. B. Ferraz
Universidade Federal de Pernambuco, Recife, Brazil
4 shared publicationsAlmino Ramos
Brazilian College of Digestive Surgery, Brazil
3 shared publications- Lyz Bezerra Silva
Universidade Federal de Pernambuco, Brazil; Hospital Santa Joana Recife, Brasil
3 shared publications - Marcelo Falcão
Department of Medicine, Bahiana School of Medicine and Public Health, Salvador, Brazil
3 shared publications
Latest Publications
- Open Access
- 19 May 2020
- Published by Springer Nature in Obesity Surgery
- Vol. 30 (8) , 3260-3262
Correction to: Endoscopic Argon Plasma Coagulation Vs. Multidisciplinary Evaluation in the Management of Weight Regain after Gastric Bypass Surgery: a Randomized Controlled Trial with SHAM Group
In the original article the captions for Figs. 1-3 are incorrect.
- 19 May 2020
- Published by Springer Nature in Obesity Surgery
- Vol. 30 (8) , 3260-3262
Open AccessCorrection to: Endoscopic Argon Plasma Coagulation Vs. Multidisciplinary Evaluation in the Management of Weight Regain after Gastric Bypass Surgery: a Randomized Controlled Trial with SHAM Group
In the original article the captions for Figs. 1-3 are incorrect.
- 5 April 2019
- Published by Springer Nature in Obesity Surgery
- Vol. 29 (8) , 2415-2419
The Effect of Sleeve Gastrectomy on the Hormonal Profile of Patients with Polycystic Ovary Syndrome
To prospectively evaluate the hormonal profile and weight loss of women with obesity and PCOS submitted to sleeve gastrectomy (SG).
- 5 April 2019
- Published by Springer Nature in Obesity Surgery
- Vol. 29 (8) , 2415-2419
The Effect of Sleeve Gastrectomy on the Hormonal Profile of Patients with Polycystic Ovary Syndrome
To prospectively evaluate the hormonal profile and weight loss of women with obesity and PCOS submitted to sleeve gastrectomy (SG).
- 27 November 2017
- Published by Springer Nature in Obesity Surgery
- Vol. 28 (2) , 594
Severe Dehiscence of Gastrojejunal Anastomosis after Gastric Bypass: Its Cure by Using Partially Covered Stent and Avoiding Migration
Gastric leak is a severe complication of gastric bypass that is associated with significant morbidity and mortality. Anastomosis dehiscence usually occurs at gastrojejunal anastomosis and can appear simultaneously with gastric leak, for which treatment can be a challenge. Fistula may have several clinical impacts, depending on patient-related factors, fistula characteristics, onset time, and therapy proposal. Abdominal toilet, drainage, gastrostomy, and revisional surgery constitute the traditional approaches to dehiscence and fistula closure, with variable results. Currently, endoscopic stents are gaining space, promoting fistula sealing, secretion deviation, treating gastric stricture, and allowing early oral diet. Herein, we present a case of severe gastrojejunal anastomosis dehiscence treated with partially covered stent.
- 27 November 2017
- Published by Springer Nature in Obesity Surgery
- Vol. 28 (2) , 594
Severe Dehiscence of Gastrojejunal Anastomosis after Gastric Bypass: Its Cure by Using Partially Covered Stent and Avoiding Migration
Gastric leak is a severe complication of gastric bypass that is associated with significant morbidity and mortality. Anastomosis dehiscence usually occurs at gastrojejunal anastomosis and can appear simultaneously with gastric leak, for which treatment can be a challenge. Fistula may have several clinical impacts, depending on patient-related factors, fistula characteristics, onset time, and therapy proposal. Abdominal toilet, drainage, gastrostomy, and revisional surgery constitute the traditional approaches to dehiscence and fistula closure, with variable results. Currently, endoscopic stents are gaining space, promoting fistula sealing, secretion deviation, treating gastric stricture, and allowing early oral diet. Herein, we present a case of severe gastrojejunal anastomosis dehiscence treated with partially covered stent.
- 1 October 2017
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 225 (4) , e3
Laparoscopic Total Gastrectomy for the Treatment of Post-Sleeve Chronic Unhealing Fistula
- 1 October 2017
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 225 (4) , e3
Laparoscopic Total Gastrectomy for the Treatment of Post-Sleeve Chronic Unhealing Fistula
- 1 October 2017
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 225 (4) , e4
New Closure Suture Technique to Prevent Petersen's Space Internal Hernia after Gastric Bypass
- 1 October 2017
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 225 (4) , e4
New Closure Suture Technique to Prevent Petersen's Space Internal Hernia after Gastric Bypass
- Open Access
- 3 January 2017
- Published by Springer Nature in BMC Research Notes
- Vol. 10 (1) , 13
Validation of a new method for the endoscopic measurement of post-bariatric gastric outlet using a standard guidewire: an observer agreement study
Between 10 and 20% of all patients undergoing bariatric surgery procedures regain weight secondary to a gastrojejunostomy enlargement. The aim of this study was to validate the interobserver agreement while measuring gastric outlet diameters using a new standard guidewire. We selected thirty-five videos of consecutive endoscopic procedures on patients undergoing esophagogastroduodenoscopy after a Roux-en-Y gastric bypass procedure. All videos were evaluated by four raters: two expert endoscopists and two trainees. We excluded videos having a slipped Fobi ring or a strictured gastric outlet. Anastomosis diameter was measured using a novel device with standardized markings on a guidewire (Hydra jagwire, Boston Scientific, Natick. MA) as well as the current gold standard defined as a calibrated endoscopic measuring instrument (Olympus America, Center Valley, PA). We obtained 272 measurements of the gastric outlet. Overall agreement measured through intra-class correlation coefficients for the gold standard was 0.84 (p < 0.01) and 0.83 (p < 0.01) for the new guidewire. Agreement among experts was 0.699 (p < 0.01), while among trainees it was 0.822 (p < 0.01). The new guidewire demonstrated a high degree of observer reliability, also presenting similar results between expert endoscopists and trainees.
- 3 January 2017
- Published by Springer Nature in BMC Research Notes
- Vol. 10 (1) , 13
Open AccessValidation of a new method for the endoscopic measurement of post-bariatric gastric outlet using a standard guidewire: an observer agreement study
Between 10 and 20% of all patients undergoing bariatric surgery procedures regain weight secondary to a gastrojejunostomy enlargement. The aim of this study was to validate the interobserver agreement while measuring gastric outlet diameters using a new standard guidewire. We selected thirty-five videos of consecutive endoscopic procedures on patients undergoing esophagogastroduodenoscopy after a Roux-en-Y gastric bypass procedure. All videos were evaluated by four raters: two expert endoscopists and two trainees. We excluded videos having a slipped Fobi ring or a strictured gastric outlet. Anastomosis diameter was measured using a novel device with standardized markings on a guidewire (Hydra jagwire, Boston Scientific, Natick. MA) as well as the current gold standard defined as a calibrated endoscopic measuring instrument (Olympus America, Center Valley, PA). We obtained 272 measurements of the gastric outlet. Overall agreement measured through intra-class correlation coefficients for the gold standard was 0.84 (p < 0.01) and 0.83 (p < 0.01) for the new guidewire. Agreement among experts was 0.699 (p < 0.01), while among trainees it was 0.822 (p < 0.01). The new guidewire demonstrated a high degree of observer reliability, also presenting similar results between expert endoscopists and trainees.
- 14 June 2016
- Published by Springer Nature in Obesity Surgery
- Vol. 26 (8) , 1992-1993
Septotomy and Balloon Dilation to Treat Chronic Leak After Sleeve Gastrectomy: Technical Principles
Chronic leaks after laparoscopic sleeve gastrectomy (LSG) are often difficult to treat by endoscopy metallic stent. Septotomy has been indicated as an effective procedure, but the technical aspects have not been detailed in previous publications (Campos JM, Siqueira LT, Ferraz AA, et al., J Am Coll Surg 204(4):711, 2007 ; Baretta G, Campos J, Correia S, et al., Surg Endosc 29(7):1714–20, 2015 ; Campos JM, Pereira EF, Evangelista LF, et al., Obes Surg 21(10):1520–9, 2011 ). We herein present a video (6 min) demonstrating the maneuver principles of this technique, showing it as a safe and feasible approach. A 32-year-old male, with BMI 43.4 kg/m2, underwent LSG. On the tenth POD, he presented with a leak and initially was managed with the following approach: laparoscopic exploration, drainage, endoclips, and 20-mm balloon dilation. However, the leak remained for a period of 6 months. On the endoscopy, a septum was identified between the leak site and gastric pouch, so it was decided to “reshape” this area by septotomy. Scope position: the endoscopist’s left hand holds the control body of the gastroscope while the right hand holds the insertion tube; the APC catheter has no need to be fixed. This avoids movements and unprogrammed maneuvers. Before cutting, the septum is placed in the six o’clock position on the endoscopic view, by rotating the gastroscope. The septum is sectioned until the bottom of the perigastric cavity (leak site). That section is made towards the staple line. Just after the septotomy, a Savory-Gilliard guidewire (Cook Medical, Indiana, USA) through the scope must be inserted until the duodenum, followed by 30-mm balloon (Rigiflex®, Boston Scientific, MA, USA) insertion. The balloon catheter must be firmly held during gradual inflation (maximum 10 psi) to avoid slippage and laceration. This allows increasing the gastric lumen. Septotomy by electrocautery with a needle knife (Boston Scientific, MA, USA) can be made when an intensive fibrotic septum is present; bleeding is rare in this case. Two sessions were performed in 15 days, resulting in leak closure. The patient was submitted to radiological control 1 week after the second session, which revealed fistula healing, without gastric stenosis. The nasoduodenal feeding tube remained for 7 days, when the patient started oral diet. This patient was followed for 18 months without recurrence. Septotomy and balloon dilation were initially performed on a difficult-to-treat chronic fistula after gastric bypass and named before as stricturotomy (Campos JM, Siqueira LT, Ferraz AA, et al., J Am Coll Surg 204(4):711, 2007 ). This procedure allows internal drainage of the fistula and deviates oral intake to the pouch. In addition, achalasia balloon dilation treats strictures and axis deviation of the gastric chamber, promoting reduction of the intragastric pressure. Septotomy and balloon dilation are technically feasible and might be useful in selected cases for closure of chronic leaks after LSG.
- 14 June 2016
- Published by Springer Nature in Obesity Surgery
- Vol. 26 (8) , 1992-1993
Septotomy and Balloon Dilation to Treat Chronic Leak After Sleeve Gastrectomy: Technical Principles
Chronic leaks after laparoscopic sleeve gastrectomy (LSG) are often difficult to treat by endoscopy metallic stent. Septotomy has been indicated as an effective procedure, but the technical aspects have not been detailed in previous publications (Campos JM, Siqueira LT, Ferraz AA, et al., J Am Coll Surg 204(4):711, 2007 ; Baretta G, Campos J, Correia S, et al., Surg Endosc 29(7):1714–20, 2015 ; Campos JM, Pereira EF, Evangelista LF, et al., Obes Surg 21(10):1520–9, 2011 ). We herein present a video (6 min) demonstrating the maneuver principles of this technique, showing it as a safe and feasible approach. A 32-year-old male, with BMI 43.4 kg/m2, underwent LSG. On the tenth POD, he presented with a leak and initially was managed with the following approach: laparoscopic exploration, drainage, endoclips, and 20-mm balloon dilation. However, the leak remained for a period of 6 months. On the endoscopy, a septum was identified between the leak site and gastric pouch, so it was decided to “reshape” this area by septotomy. Scope position: the endoscopist’s left hand holds the control body of the gastroscope while the right hand holds the insertion tube; the APC catheter has no need to be fixed. This avoids movements and unprogrammed maneuvers. Before cutting, the septum is placed in the six o’clock position on the endoscopic view, by rotating the gastroscope. The septum is sectioned until the bottom of the perigastric cavity (leak site). That section is made towards the staple line. Just after the septotomy, a Savory-Gilliard guidewire (Cook Medical, Indiana, USA) through the scope must be inserted until the duodenum, followed by 30-mm balloon (Rigiflex®, Boston Scientific, MA, USA) insertion. The balloon catheter must be firmly held during gradual inflation (maximum 10 psi) to avoid slippage and laceration. This allows increasing the gastric lumen. Septotomy by electrocautery with a needle knife (Boston Scientific, MA, USA) can be made when an intensive fibrotic septum is present; bleeding is rare in this case. Two sessions were performed in 15 days, resulting in leak closure. The patient was submitted to radiological control 1 week after the second session, which revealed fistula healing, without gastric stenosis. The nasoduodenal feeding tube remained for 7 days, when the patient started oral diet. This patient was followed for 18 months without recurrence. Septotomy and balloon dilation were initially performed on a difficult-to-treat chronic fistula after gastric bypass and named before as stricturotomy (Campos JM, Siqueira LT, Ferraz AA, et al., J Am Coll Surg 204(4):711, 2007 ). This procedure allows internal drainage of the fistula and deviates oral intake to the pouch. In addition, achalasia balloon dilation treats strictures and axis deviation of the gastric chamber, promoting reduction of the intragastric pressure. Septotomy and balloon dilation are technically feasible and might be useful in selected cases for closure of chronic leaks after LSG.
- 1 May 2016
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 83 (5) , AB636
GERD Following Sleeve Gastrectomy: A Novel Endoscopic Approach
- 1 May 2016
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 83 (5) , AB636
GERD Following Sleeve Gastrectomy: A Novel Endoscopic Approach
- 1 May 2016
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 83 (5) , AB195
1039 Endoscopic Septotomy for Sleeve Gastrectomy Leak After Failed Stent
- 1 May 2016
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 83 (5) , AB195
1039 Endoscopic Septotomy for Sleeve Gastrectomy Leak After Failed Stent
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S828
Mo1961 Endoscopic Septotomy: An Effective Strategy for Drainage of Sleeve Gastrectomy-Associated Collections
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S828
Mo1961 Endoscopic Septotomy: An Effective Strategy for Drainage of Sleeve Gastrectomy-Associated Collections