Ziauddin Khan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ziauddin Khan has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Subrata Pradhan
Institute for Plasma Research
5 shared publications Siju George
Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar 382 428, India
4 shared publicationsYuvakiran Paravastu
Institute for Plasma Research, Gandhinagar, India
4 shared publicationsPrashant Thankey
Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar 382 428, India
3 shared publicationsPratibha Semwal
Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar 382 428, India
3 shared publicationsSubrata Pradhan
Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar 382 428, India
3 shared publications
Latest Publications
- Open Access
- 19 April 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 823 (1) , 012060
Overall behaviour of PFC integrated SST-1 vacuum system
As a part of phase-I up-gradation of Steady-state Superconducting Tokamak (SST-1), Graphite Plasma Facing Components (PFCs) have been integrated inside SST-1 vacuum vessel as a first wall (FW) during Nov 14 and May 2015. The SST-1 FW has a total surface area of the installed PFCs exposed to plasma is ~ 40 m2 which is nearly 50% of the total surface area of stainless steel vacuum chamber (~75 m2). The volume of the vessel within the PFCs is ~ 16 m3. After the integration of PFCs, the entire vessel as well as the PFC cooling/baking circuits has been qualified with an integrated helium leak tightness of < 1.0 x 10-8 mbar 1/s. The pumping system of the SST-1 vacuum vessel comprises of one number of Roots' pump, four numbers of turbomolecular pumps and a cryopump. After the initial pump down, the PFCs were baked at 250 °C for nearly 20 hours employing hot nitrogen gas to remove the absorbed water vapours. Thereafter, Helium glow discharges cleaning were carried out towards the removal of surface impurities. The pump down characteristics of SST-1 vacuum chamber and the changes in the residual gaseous impurities after the installation of the PFCs will be discussed in this paper.
- 19 April 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 823 (1) , 012060
Open AccessOverall behaviour of PFC integrated SST-1 vacuum system
As a part of phase-I up-gradation of Steady-state Superconducting Tokamak (SST-1), Graphite Plasma Facing Components (PFCs) have been integrated inside SST-1 vacuum vessel as a first wall (FW) during Nov 14 and May 2015. The SST-1 FW has a total surface area of the installed PFCs exposed to plasma is ~ 40 m2 which is nearly 50% of the total surface area of stainless steel vacuum chamber (~75 m2). The volume of the vessel within the PFCs is ~ 16 m3. After the integration of PFCs, the entire vessel as well as the PFC cooling/baking circuits has been qualified with an integrated helium leak tightness of < 1.0 x 10-8 mbar 1/s. The pumping system of the SST-1 vacuum vessel comprises of one number of Roots' pump, four numbers of turbomolecular pumps and a cryopump. After the initial pump down, the PFCs were baked at 250 °C for nearly 20 hours employing hot nitrogen gas to remove the absorbed water vapours. Thereafter, Helium glow discharges cleaning were carried out towards the removal of surface impurities. The pump down characteristics of SST-1 vacuum chamber and the changes in the residual gaseous impurities after the installation of the PFCs will be discussed in this paper.
- 15 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 25 (2) , 1-7
Cryogenic Acceptance Tests of SST-1 Superconducting Coils
Toroidal field (TF) and poloidal field (PF) coils of steady-state superconducting tokamak (SST-1) have been fully refurbished to ensure cryostable and low-dc-resistance interpancake and intercoil joints, helium leak tightness of the winding pack, and ) 10 MΩ winding pack to ground insulation resistance under cold conditions. As per SST-1 mission mandate, all TF coils and PF3 Top had been cold tested at full operational parameters. A dedicated large coil test facility was integrated for these tests. Specially adapted solutions such as magnet preparation cum transport stand, demountable busbar supports, demountable sensor mountings, reusable joints for busbar connections inside cryostat, etc., were developed. These measures led to timely and successful completion of cold tests and integration of the magnet system on to the SST-1 machine shell. The functionality of various diagnostics of the magnet system was also established during these tests. Details of coil refurbishment, test facility, test campaigns, and some important test results are reported in this paper.
- 15 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 25 (2) , 1-7
Cryogenic Acceptance Tests of SST-1 Superconducting Coils
Toroidal field (TF) and poloidal field (PF) coils of steady-state superconducting tokamak (SST-1) have been fully refurbished to ensure cryostable and low-dc-resistance interpancake and intercoil joints, helium leak tightness of the winding pack, and ) 10 MΩ winding pack to ground insulation resistance under cold conditions. As per SST-1 mission mandate, all TF coils and PF3 Top had been cold tested at full operational parameters. A dedicated large coil test facility was integrated for these tests. Specially adapted solutions such as magnet preparation cum transport stand, demountable busbar supports, demountable sensor mountings, reusable joints for busbar connections inside cryostat, etc., were developed. These measures led to timely and successful completion of cold tests and integration of the magnet system on to the SST-1 machine shell. The functionality of various diagnostics of the magnet system was also established during these tests. Details of coil refurbishment, test facility, test campaigns, and some important test results are reported in this paper.
- 24 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 42 (4) , 1006-1011
Overall Performance of SST-1 Tokamak Vacuum System
Vacuum system of steady-state superconducting tokamak (SST-1) is comprised of 23 m 3 ultrahigh vacuum (UHV) chamber with baking channels embedded on the vacuum vessel (VV) being heated with a dedicated nitrogen gas baking facility, gas puffing system, wall conditioning system and 39 m 3 high vacuum cryostat (CST) chamber housing the superconducting magnets, cold structures, 80-K thermal shields and associated auxiliary components. The pumping system for the SST-1 VV consists of two turbo-molecular pumps each of 5500 l/s (N 2 gas) capacity providing a total effective pumping speed of 4675 l/s and the CST consists of three such pumps with a total effective pumping speed of 3250 l/s. To achieve UHV inside the VV, it was baked at 135 °C for a longer duration of 100 h, while four numbers of graphite based limiters were baked at 250 °C for 50 h. An ultimate pressure of 4.6 × 10 -8 mbar was achieved inside VV while an ultimate vacuum achieved inside the CST was 1.1 × 10 -5 mbar. The gas puffing system has performed satisfactorily during the plasma trials assisted with electron cyclotron resonance heating preionizations. This paper describes our overall experience during the entire campaign of successful operation of SST-1 during first plasma.
- 24 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 42 (4) , 1006-1011
Overall Performance of SST-1 Tokamak Vacuum System
Vacuum system of steady-state superconducting tokamak (SST-1) is comprised of 23 m 3 ultrahigh vacuum (UHV) chamber with baking channels embedded on the vacuum vessel (VV) being heated with a dedicated nitrogen gas baking facility, gas puffing system, wall conditioning system and 39 m 3 high vacuum cryostat (CST) chamber housing the superconducting magnets, cold structures, 80-K thermal shields and associated auxiliary components. The pumping system for the SST-1 VV consists of two turbo-molecular pumps each of 5500 l/s (N 2 gas) capacity providing a total effective pumping speed of 4675 l/s and the CST consists of three such pumps with a total effective pumping speed of 3250 l/s. To achieve UHV inside the VV, it was baked at 135 °C for a longer duration of 100 h, while four numbers of graphite based limiters were baked at 250 °C for 50 h. An ultimate pressure of 4.6 × 10 -8 mbar was achieved inside VV while an ultimate vacuum achieved inside the CST was 1.1 × 10 -5 mbar. The gas puffing system has performed satisfactorily during the plasma trials assisted with electron cyclotron resonance heating preionizations. This paper describes our overall experience during the entire campaign of successful operation of SST-1 during first plasma.
- 1 October 2013
- Published by Elsevier in Fusion Engineering and Design
- Vol. 88 (6-8) , 692-695
Vacuum system of SST-1 Tokamak
- 1 October 2013
- Published by Elsevier in Fusion Engineering and Design
- Vol. 88 (6-8) , 692-695
Vacuum system of SST-1 Tokamak
- 13 March 2013
- Published by Gokaraju Rangaraju Educational Society in International Journal of Advanced Materials Manufacturing and Characterization
- Vol. 3 (1) , 127-130
Ybco Superconductor Characterization under Shear Strain
- 13 March 2013
- Published by Gokaraju Rangaraju Educational Society in International Journal of Advanced Materials Manufacturing and Characterization
- Vol. 3 (1) , 127-130
Ybco Superconductor Characterization under Shear Strain
- 1 February 2013
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 15 (2) , 157-160
Nitrogen Gas Heating and Supply System for SST-1 Tokamak
- 1 February 2013
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 15 (2) , 157-160
Nitrogen Gas Heating and Supply System for SST-1 Tokamak
- 1 February 2013
- Published by IOP Publishing in Physica Scripta
- Vol. 87 (3) , 035704
Characterization of a laboratory scale high-Tc‘D-shaped’ magnet
A 'D-shaped' laboratory scale magnet resembling the toroidal field magnet of a tokamak has been fabricated using technical grade BSCCO high-Tc superconductor tape. The I–V characteristic as a function of the current ramp rate, as well as the critical current behavior under low external transverse magnetic fields, has been experimentally investigated at liquid nitrogen temperature. Degradation up to 46% in the critical current of the magnet with respect to its virgin tape has been observed. Hysteresis behavior has also been observed during ramp-up and ramp-down. The normal zone propagation velocity for quenching the magnet has been obtained experimentally to be 2.5 cm s−1 for a transport current of 60 A at 80 K for the critical current of about 150 A.
- 1 February 2013
- Published by IOP Publishing in Physica Scripta
- Vol. 87 (3) , 035704
Characterization of a laboratory scale high-Tc‘D-shaped’ magnet
A 'D-shaped' laboratory scale magnet resembling the toroidal field magnet of a tokamak has been fabricated using technical grade BSCCO high-Tc superconductor tape. The I–V characteristic as a function of the current ramp rate, as well as the critical current behavior under low external transverse magnetic fields, has been experimentally investigated at liquid nitrogen temperature. Degradation up to 46% in the critical current of the magnet with respect to its virgin tape has been observed. Hysteresis behavior has also been observed during ramp-up and ramp-down. The normal zone propagation velocity for quenching the magnet has been obtained experimentally to be 2.5 cm s−1 for a transport current of 60 A at 80 K for the critical current of about 150 A.
- Open Access
- 1 June 2012
- Published by Springer Nature in Bulletin of Materials Science
- Vol. 35 (3) , 449-451
Heat conduction and thermal stabilization in YBCO tape
- 1 June 2012
- Published by Springer Nature in Bulletin of Materials Science
- Vol. 35 (3) , 449-451
Open AccessHeat conduction and thermal stabilization in YBCO tape