  • Evaluation of endodontic files in digital radiographs before and after employing three image processing algorithms

    by G Li, Gch Sanderink, U Welander, WD McDavid, K Näsström

    Objectives: Two digital image processing algorithms, one aimed at correction for exponential attenuation and one at correction for visual response, have been developed. The aims of the present study were to test whether digital radiographs processed with these algorithms improve determination of the length of endodontic files and whether such processed radiographs are comparable with the radiographs processed with a default image processing method employed by one commercially available digital intraoral system. Methods: A dried human skull embedded in an acrylic compound was used for exposing radiographs of the upper and lower premolars and molars with endodontic files (Kerr files size 10 and size 15) positioned to the full length of the roots or 1.5 mm short of it. Radiographs were then processed in three sets. In one set, the radiographs were processed to compensate for exponential attenuation and the response of the human visual system. In the second, the radiographs were processed with the same compen...


  • Perceptibility curve test for digital radiographs before and after correction for attenuation and correction for attenuation and visual response

    by G Li, U Welander, K Yoshiura, X-Q Shi, WD McDavid

    Objective: Two digital image processing methods, correction for X-ray attenuation and correction for attenuation and visual response, have been developed. The aim of the present study was to compare digital radiographs before and after correction for attenuation and correction for attenuation and visual response by means of a perceptibility curve test. Material and methods: Radiographs were exposed of an aluminium test object containing holes ranging from 0.03 mm to 0.30 mm with increments of 0.03 mm. Fourteen radiographs were exposed with the Dixi system (Planmeca Oy, Helsinki, Finland) and twelve radiographs were exposed with the F1 iOX system (Fimet Oy, Monninkylä, Finland) from low to high exposures covering the full exposure ranges of the systems. Radiographs obtained from the Dixi and F1 iOX systems were 12 bit and 8 bit images, respectively. Original radiographs were then processed for correction for attenuation and correction for attenuation and visual response. Thus, two series of radiographs wer...


  • Detection of approximal caries in digital radiographs before and after correction for attenuation and visual response. An in vitro study.

    by G Li, K Yoshiura, U Welander, X Q Shi, W D McDavid

    OBJECTIVE To evaluate if digital compensation for exponential attenuation and the characteristics of the human visual system improves the diagnosis of approximal caries from digital radiographs. MA...


  • Visual linearization of the display of digital radiographs.

    by G Li, K Yoshiura, U Welander, P Sällstrom, W D McDavid

    OBJECTIVES: To derive and test a method to linearize the visual response of the display of digital radiographs so that equal steps in gray levels will be perceived as equal steps in brightness. METHOD: A mathematical analysis was performed and expressions for visual linearization were derived. Twenty-four test images were computer generated to confirm that visual linearization may be achieved. Each image had three groups of square areas of different size placed in three rows. The left and right squares in each row were given different gray levels to simulate various contrast levels. The middle squares were initially given the same gray level value as one of the outer squares. The images were examined by ten observers who could change the gray levels of the middle squares so that the step in brightness between the middle square and the outer squares become subjectively equal. The test was performed three times employing two different monitors. RESULTS: The experimental test confirmed that visual linearization could be achieved. Linear regression analyses gave determination coefficients of 0.9926 amd 0.9942 for monitors with gamma-values of 1.93 and 2.50. respectively. The mean data from the ten observers perfectly fitted those theoretically calculated. CONCLUSION: Visual linearization of gray levels can be achieved but further clinical research is needed to determine if this improves diagnosis.