Michael Kempe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael Kempe has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Alexander Froeber
Carl Zeiss AG (Germany)
1 shared publicationCarsten Wehe
Carl Zeiss AG (Germany)
1 shared publicationDirk Thiele
Carl Zeiss AG (Germany)
1 shared publicationGerhard Krampert
Carl Zeiss AG (Germany)
1 shared publicationIngo Kleppe
Carl Zeiss Microscopy GmbH, Carl Zeiss Promenade 10, 07745 Jena, Germany
1 shared publicationJoerg Muetze
Carl Zeiss AG (Germany)
1 shared publication
Latest Publications
- Open Access
- 3 November 2020
- Published by Wiley in Translational Biophotonics
- Vol. 3 (1)
Optical coherence tomography: From technology to applications in ophthalmology
The relatively fast translation of optical coherence tomography (OCT) from an optical measurement technology to a standard of care in ophthalmology was driven by its ability to address clear unmet diagnostic needs. OCT's further technological developments have expanded its clinical use by extending the imaging range (wider, deeper) and the imaging contrast (from morphology to blood flow). The translation of technical advances into clinical value is an ongoing process involving both the potential substitution of established diagnostics (such as fundus angiography) and the identification of novel feature‐disease correlations. This review looks into the development, the status and the prospects of OCT with regard to translation to clinical routine in ophthalmology.
- 3 November 2020
- Published by Wiley in Translational Biophotonics
- Vol. 3 (1)
Open AccessOptical coherence tomography: From technology to applications in ophthalmology
The relatively fast translation of optical coherence tomography (OCT) from an optical measurement technology to a standard of care in ophthalmology was driven by its ability to address clear unmet diagnostic needs. OCT's further technological developments have expanded its clinical use by extending the imaging range (wider, deeper) and the imaging contrast (from morphology to blood flow). The translation of technical advances into clinical value is an ongoing process involving both the potential substitution of established diagnostics (such as fundus angiography) and the identification of novel feature‐disease correlations. This review looks into the development, the status and the prospects of OCT with regard to translation to clinical routine in ophthalmology.
- 4 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10931, 109310K-20
Integrated confocal imaging system
We report on a concept of a benchtop microscope for routine applications. This concept system transfers key features of a high-end laser scanning microscope to a dedicated confocal fluorescence imaging system with appropriate footprint and reduced systems complexity. The optical beam path is specifically designed for the purposes of confocal imaging leading to a short beam path length that fulfills the footprint requirements. The system allows an optical 3D scanning through the sample of up to 100 depths of focus without moving the sample. The scanning unit consists of a 2D MEMS scanning mirror spanning and a deformable mirror forming 3 virtual scanning axes. For a compact integration of the detection beam path, a confocal detector with an actuated MEMS pinhole was developed to adjust the optical sectioning. The selected light sources are directly modulated lasers operating at wavelengths that are frequently used for fluorescence imaging in life science applications. To provide a simple interface to almost any user’s hardware such as laptops or tablets, the systems architecture for real time control and data acquisition is based on a FPGA.
- 4 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10931, 109310K-20
Integrated confocal imaging system
We report on a concept of a benchtop microscope for routine applications. This concept system transfers key features of a high-end laser scanning microscope to a dedicated confocal fluorescence imaging system with appropriate footprint and reduced systems complexity. The optical beam path is specifically designed for the purposes of confocal imaging leading to a short beam path length that fulfills the footprint requirements. The system allows an optical 3D scanning through the sample of up to 100 depths of focus without moving the sample. The scanning unit consists of a 2D MEMS scanning mirror spanning and a deformable mirror forming 3 virtual scanning axes. For a compact integration of the detection beam path, a confocal detector with an actuated MEMS pinhole was developed to adjust the optical sectioning. The selected light sources are directly modulated lasers operating at wavelengths that are frequently used for fluorescence imaging in life science applications. To provide a simple interface to almost any user’s hardware such as laptops or tablets, the systems architecture for real time control and data acquisition is based on a FPGA.
- 2 April 2013
- Published by Frontiers Media SA in Advanced Optical Technologies
- Vol. 2 (3) , 211-231
Super-resolution microscopy heads towards 3D dynamics
Resolving fine details of subcellular structures is key to understanding the organization and function of cellular networks. Recent advances in far-field fluorescence microscopy provide the necessary tools to analyze these structures with resolutions well below the classical diffraction limit in all three dimensions. Technical improvements go hand-in-hand with new versions of switchable fluorophores that allow nonlinear optical effects to be more efficiently used to push the resolution limit down further. High contrast combined with the wide spectrum of available colors currently endow these fluorescence-based super-resolution techniques with the power to study the complexity of subcellular organelles and the relation of their constituting components down to the molecular level and under physiological conditions. In this way, they give us a far better understanding of the assembly of macromolecular complexes and their functions within a cell than has been possible before employing conventional imaging methods. In this review, we give an overview of the technical state-of-the art of these technologies, their fundamental and technical trade-offs, and provide typical application examples in this exciting field.
- 2 April 2013
- Published by Frontiers Media SA in Advanced Optical Technologies
- Vol. 2 (3) , 211-231
Super-resolution microscopy heads towards 3D dynamics
Resolving fine details of subcellular structures is key to understanding the organization and function of cellular networks. Recent advances in far-field fluorescence microscopy provide the necessary tools to analyze these structures with resolutions well below the classical diffraction limit in all three dimensions. Technical improvements go hand-in-hand with new versions of switchable fluorophores that allow nonlinear optical effects to be more efficiently used to push the resolution limit down further. High contrast combined with the wide spectrum of available colors currently endow these fluorescence-based super-resolution techniques with the power to study the complexity of subcellular organelles and the relation of their constituting components down to the molecular level and under physiological conditions. In this way, they give us a far better understanding of the assembly of macromolecular complexes and their functions within a cell than has been possible before employing conventional imaging methods. In this review, we give an overview of the technical state-of-the art of these technologies, their fundamental and technical trade-offs, and provide typical application examples in this exciting field.