Olusola O. Fasunwon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Olusola O. Fasunwon has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Guadagnini
Dipartimento di Ingegneria Civile e Ambientale (DICA) Politecnico di Milano Milan Italy
1 shared publication John A. Olowofela
Ibadan, Nigeria
1 shared publication- Monica Riva
Dipartimento di Ingegneria Civile e Ambientale, Politecnico di Milano, Milano, Italy
1 shared publication Ojok O. Ocan
Department of Geology, Obafemi Awolowo University, Ile-Ife, Nigeria
1 shared publication- Olukayode Dewumi Akinyemi
Environmental Systems and Climate Change Programme, Africa Centre of Excellence in Agricultural Development and Sustainable Environment, Federal University of Agriculture, Abeokuta, Nigeria
1 shared publication - Philippe Ackerer
Institut Terre et Environnement de Strasbourg, Université de Strasbourg, CNRS, ENGEES, F-67000 Strasbourg, France
1 shared publication
Latest Publications
- 1 June 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Hydraulic Engineering
- Vol. 139 (6) , 637-644
New General Analytical Solution for Infiltration Structures Design
This paper develops an analytical solution to assist in designing and sizing stormwater infiltration structures. As original elements, our solution allows to estimate the hydraulic head in the infiltration structure as a function of (1) storm temporal dynamics, making use of an appropriate intensity duration frequency (IDF) curve, (2) the model adopted to describe the response of the catchment to a given input rainfall, and (3) the evolution of the wetted front advancing in a homogeneous soil where the infiltration device is located. Our solution allows highlighting the effects of the various simplifications associated with existing formulations employed in the common engineering practice. Our results indicate that typically adopted methodologies based on the assumptions of a uniform infiltration rate and/or negligible flow rate along the lateral surface of the structure may lead to overestimating the key design parameters.
- 1 June 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Hydraulic Engineering
- Vol. 139 (6) , 637-644
New General Analytical Solution for Infiltration Structures Design
This paper develops an analytical solution to assist in designing and sizing stormwater infiltration structures. As original elements, our solution allows to estimate the hydraulic head in the infiltration structure as a function of (1) storm temporal dynamics, making use of an appropriate intensity duration frequency (IDF) curve, (2) the model adopted to describe the response of the catchment to a given input rainfall, and (3) the evolution of the wetted front advancing in a homogeneous soil where the infiltration device is located. Our solution allows highlighting the effects of the various simplifications associated with existing formulations employed in the common engineering practice. Our results indicate that typically adopted methodologies based on the assumptions of a uniform infiltration rate and/or negligible flow rate along the lateral surface of the structure may lead to overestimating the key design parameters.
- Open Access
- 1 January 2008
- Published by National Library of Serbia in Thermal Science
- Vol. 12 (2) , 119-128
Determination of thermal conductivity of rocks samples using fabricated equipment
The aim of the paper is to describe how inexpensive/simple physics equipment was fabricated and used in the determination of thermal conductivity of rock samples. We used the experimental techniques known as transient method of measuring thermal properties of rock samples at ambient temperature. We investigated samples found in five locations/region (Ewekoro, Ile-Ife, Igara, Ago-Iwoye, Abeokuta) in South western Nigeria. Those samples are limestone, dolerite, marble, gneiss, and granite. Although the samples are multi-mineral as revealed by photomicrograph, the thermal conductivity results obtained 1.40, 1.50, 1.57, 1.75, and 2.94 W/m?C, respectively, are found to be consistent with the ones in literature where highly expensive and sophisticated (not easily affordable in developing nation) equipment are used. .
- 1 January 2008
- Published by National Library of Serbia in Thermal Science
- Vol. 12 (2) , 119-128
Open AccessDetermination of thermal conductivity of rocks samples using fabricated equipment
The aim of the paper is to describe how inexpensive/simple physics equipment was fabricated and used in the determination of thermal conductivity of rock samples. We used the experimental techniques known as transient method of measuring thermal properties of rock samples at ambient temperature. We investigated samples found in five locations/region (Ewekoro, Ile-Ife, Igara, Ago-Iwoye, Abeokuta) in South western Nigeria. Those samples are limestone, dolerite, marble, gneiss, and granite. Although the samples are multi-mineral as revealed by photomicrograph, the thermal conductivity results obtained 1.40, 1.50, 1.57, 1.75, and 2.94 W/m?C, respectively, are found to be consistent with the ones in literature where highly expensive and sophisticated (not easily affordable in developing nation) equipment are used. .