Bart Nuttin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bart Nuttin has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Robert Puers
ESAT-MICAS, KU Leuven, Kasteelpark Arenberg 10, 3001 Leuven, Belgium
2 shared publications - Dries Kil
ESAT-MICAS, KU Leuven, 3001 Leuven, Belgium
1 shared publication - Frederik Ceyssens
ESAT-MICAS, KU Leuven, Kasteelpark Arenberg 10, 3001 Leuven, Belgium
1 shared publication - Greetje Vande Velde
Biomedical MRI, Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
1 shared publication - Kris van Kuyck
KU Leuven, Belgium
1 shared publication - Linda Stappers
KU Leuven
1 shared publication
Latest Publications
- Open Access
- 1 January 2016
- Published by Elsevier in Procedia Engineering
- Vol. 168, 137-142
A Foldable Neural Electrode for 3D Stimulation of Deep Brain Cavities
- 1 January 2016
- Published by Elsevier in Procedia Engineering
- Vol. 168, 137-142
Open AccessA Foldable Neural Electrode for 3D Stimulation of Deep Brain Cavities
- 16 February 2013
- Published by Springer Nature in Biomedical Microdevices
- Vol. 15 (3) , 481-493
Resorbable scaffold based chronic neural electrode arrays
We have developed a novel type of neural electrode array for future brain-machine interfaces (BMI) and neural implants requiring high resolution recording and stimulation on the surface of brain lesions or on the cortex. The devices differ on two points from commonly used thin film electrode arrays: first, the thin film backbone of the implant is exceptionally thin (down to 5 microns) and finely patterned into spring-like structures. This increases the flexibility of the electrode array and allows stretching and conforming better to a quasi spherical cavity surface. Second, the thin film backbone of the device is reinforced with a porous layer of resorbable chitosan. This design aims at minimal invasiveness and low mechanical irritation during prolonged use, while the chitosan matrix ensures the implant is stiff enough for practical handling during the implantation procedure and dissolves afterwards. Furthermore, the chitosan adds haemostatic and antiseptic properties to the implant and improves adhesion. In the article, the design and fabrication process are presented. In vitro and long term in vivo test results over a 12 month period are shown. By adopting the use of a resorbable scaffold-like material as main constituent of neural implants, the presented work opens up the possibility of applying tissue engineering techniques to further improve neural implant technology.
- 16 February 2013
- Published by Springer Nature in Biomedical Microdevices
- Vol. 15 (3) , 481-493
Resorbable scaffold based chronic neural electrode arrays
We have developed a novel type of neural electrode array for future brain-machine interfaces (BMI) and neural implants requiring high resolution recording and stimulation on the surface of brain lesions or on the cortex. The devices differ on two points from commonly used thin film electrode arrays: first, the thin film backbone of the implant is exceptionally thin (down to 5 microns) and finely patterned into spring-like structures. This increases the flexibility of the electrode array and allows stretching and conforming better to a quasi spherical cavity surface. Second, the thin film backbone of the device is reinforced with a porous layer of resorbable chitosan. This design aims at minimal invasiveness and low mechanical irritation during prolonged use, while the chitosan matrix ensures the implant is stiff enough for practical handling during the implantation procedure and dissolves afterwards. Furthermore, the chitosan adds haemostatic and antiseptic properties to the implant and improves adhesion. In the article, the design and fabrication process are presented. In vitro and long term in vivo test results over a 12 month period are shown. By adopting the use of a resorbable scaffold-like material as main constituent of neural implants, the presented work opens up the possibility of applying tissue engineering techniques to further improve neural implant technology.