Michael F. Insana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michael F. Insana has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Timothy Hall
Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, USA
6 shared publications Glendon G. Cox
Department of Radiology, Kansas University Medical Center, Kansas City, Kansas 66160‐7234
5 shared publications- Larry T. Cook
Univ. of Kansas Medical Ctr. (United States)
5 shared publications Michael A. McFadden
Department of Radiology, Kansas University Medical Center, Kansas City, Kansas 66160‐7234
5 shared publicationsKaren K. Lindfors
Univ. of California, Davis Medical Ctr. (United States)
2 shared publicationsP. Chaturvedi
Sprint PCS, 15405 College Boulevard, Lenexa, Kansas 66219
2 shared publications
Latest Publications
- 2 March 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6146
Observer efficiency in boundary discrimination tasks related to assessment of breast lesions with ultrasound
The statistical efficiency of human observers in diagnostic tasks is an important measure of how effectively task relevant information in the image is being utilized. Most efficiency studies have investigated efficiency in terms of contrast or size effects. In many cases, malignant lesions will have similar contrast to normal or benign objects, but can be distinguished by properties of their boundary. We investigate this issue in the framework of malignant/benign discrimination tasks for the breast with ultrasound. In order to identify effects in terms of specific features and to control for other effects such as aberration or specular reflections, we simulate the formation of beam-formed radio-frequency (RF) data. We consider three tasks related to lesion boundaries including boundary eccentricity, boundary sharpness, and detection of boundary spiculations. We also consider standard detection and contrast discrimination tasks. We find that human observers exhibit surprisingly low efficiency with respect to the Ideal observer acting on RF data in boundary discrimination tasks (0.08%-3.3%), and that efficiency of human observers is substantially increased by Wiener-filtering RF frame data. We also find a limitation in efficiency is the computation of an envelope image from the RF data recorded by the transducer. Approximations to the Ideal observer acting on the envelope images indicate that humans may be substantially more efficient (10%-75%) with respect to the envelope Ideal observers. Our work suggests that significant diagnostic information may be lost in standard envelope processing in the formation of ultrasonic images.
- 2 March 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6146
Observer efficiency in boundary discrimination tasks related to assessment of breast lesions with ultrasound
The statistical efficiency of human observers in diagnostic tasks is an important measure of how effectively task relevant information in the image is being utilized. Most efficiency studies have investigated efficiency in terms of contrast or size effects. In many cases, malignant lesions will have similar contrast to normal or benign objects, but can be distinguished by properties of their boundary. We investigate this issue in the framework of malignant/benign discrimination tasks for the breast with ultrasound. In order to identify effects in terms of specific features and to control for other effects such as aberration or specular reflections, we simulate the formation of beam-formed radio-frequency (RF) data. We consider three tasks related to lesion boundaries including boundary eccentricity, boundary sharpness, and detection of boundary spiculations. We also consider standard detection and contrast discrimination tasks. We find that human observers exhibit surprisingly low efficiency with respect to the Ideal observer acting on RF data in boundary discrimination tasks (0.08%-3.3%), and that efficiency of human observers is substantially increased by Wiener-filtering RF frame data. We also find a limitation in efficiency is the computation of an envelope image from the RF data recorded by the transducer. Approximations to the Ideal observer acting on the envelope images indicate that humans may be substantially more efficient (10%-75%) with respect to the envelope Ideal observers. Our work suggests that significant diagnostic information may be lost in standard envelope processing in the formation of ultrasonic images.
- 1 October 2004
- Published by Springer Nature in Journal of Mammary Gland Biology and Neoplasia
- Vol. 9 (4) , 393-404
Viscoelastic Imaging of Breast Tumor Microenvironment With Ultrasound
Imaging systems are most effective for detection and classification when they exploit contrast mechanisms specific to particular disease processes. A common example is mammography, where the contrast depends on local changes in cell density and the presence of microcalcifications. Unfortunately the specificity for classifying malignant breast disease is relatively low for many current diagnostic techniques. This paper describes a new ultrasonic technique for imaging the viscoelastic properties of breast tissue. The mechanical properties of glandular breast tissue, like most biopolymers, react to mechanical stimuli in a manner specific to the microenvironment of the tissue. Elastic properties allow noninvasive imaging of desmoplasia while viscous properties describe metabolism-dependent features such as pH. These ultrasonic methods are providing new tools for studying disease mechanisms as well as improving diagnosis.
- 1 October 2004
- Published by Springer Nature in Journal of Mammary Gland Biology and Neoplasia
- Vol. 9 (4) , 393-404
Viscoelastic Imaging of Breast Tumor Microenvironment With Ultrasound
Imaging systems are most effective for detection and classification when they exploit contrast mechanisms specific to particular disease processes. A common example is mammography, where the contrast depends on local changes in cell density and the presence of microcalcifications. Unfortunately the specificity for classifying malignant breast disease is relatively low for many current diagnostic techniques. This paper describes a new ultrasonic technique for imaging the viscoelastic properties of breast tissue. The mechanical properties of glandular breast tissue, like most biopolymers, react to mechanical stimuli in a manner specific to the microenvironment of the tissue. Elastic properties allow noninvasive imaging of desmoplasia while viscous properties describe metabolism-dependent features such as pH. These ultrasonic methods are providing new tools for studying disease mechanisms as well as improving diagnosis.
- 6 February 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 23 (2) , 153-163
Ultrasound Elastography Based on Multiscale Estimations of Regularized Displacement Fields
Elasticity imaging is based on the measurements of local tissue deformation. The approach to ultrasound elasticity imaging presented in this paper relies on the estimation of dense displacement fields by a coarse-to-fine minimization of an energy function that combines constraints of conservation of echo amplitude and displacement field continuity. The multiscale optimization scheme presents several characteristics aimed at improving and accelerating the convergence of the minimization process. This includes the nonregularized initialization at the coarsest resolution and the use of adaptive configuration spaces. Parameters of the energy model and optimization were adjusted using data obtained from a tissue-like phantom material. Elasticity images from normal in vivo breast tissue were subsequently obtained with these parameters. Introducing a smoothness constraint into motion field estimation helped solve ambiguities due to incoherent motion, leading to elastograms less degraded by decorrelation noise than the ones obtained from correlation-based techniques.
- 6 February 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 23 (2) , 153-163
Ultrasound Elastography Based on Multiscale Estimations of Regularized Displacement Fields
Elasticity imaging is based on the measurements of local tissue deformation. The approach to ultrasound elasticity imaging presented in this paper relies on the estimation of dense displacement fields by a coarse-to-fine minimization of an energy function that combines constraints of conservation of echo amplitude and displacement field continuity. The multiscale optimization scheme presents several characteristics aimed at improving and accelerating the convergence of the minimization process. This includes the nonregularized initialization at the coarsest resolution and the use of adaptive configuration spaces. Parameters of the energy model and optimization were adjusted using data obtained from a tissue-like phantom material. Elasticity images from normal in vivo breast tissue were subsequently obtained with these parameters. Introducing a smoothness constraint into motion field estimation helped solve ambiguities due to incoherent motion, leading to elastograms less degraded by decorrelation noise than the ones obtained from correlation-based techniques.
- 22 July 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 50 (7) , 824-835
Adaptive clutter rejection filtering in ultrasonic strain-flow imaging
This paper introduces strain-flow imaging as a potential new technique for investigating vascular dynamics and tumor biology. The deformation of tissues surrounding pulsatile vessels and the velocity of fluid in the vessel are estimated from the same data set. The success of the approach depends on the performance of a digital filter that must separate echo signal components caused by flow from tissue motion components that vary spatially and temporally. Eigenfilters, which are an important tool for naturally separating signal components adaptively throughout the image, perform very well for this task. The method is examined using two tissue-mimicking flow phantoms that provide stationary and moving clutter associated with pulsatile flow.
- 22 July 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 50 (7) , 824-835
Adaptive clutter rejection filtering in ultrasonic strain-flow imaging
This paper introduces strain-flow imaging as a potential new technique for investigating vascular dynamics and tumor biology. The deformation of tissues surrounding pulsatile vessels and the velocity of fluid in the vessel are estimated from the same data set. The success of the approach depends on the performance of a digital filter that must separate echo signal components caused by flow from tissue motion components that vary spatially and temporally. Eigenfilters, which are an important tool for naturally separating signal components adaptively throughout the image, perform very well for this task. The method is examined using two tissue-mimicking flow phantoms that provide stationary and moving clutter associated with pulsatile flow.
- 9 July 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 50 (6) , 642-654
Linear system models for ultrasonic imaging: application to signal statistics
Linear equations for modeling echo signals from shift-variant systems forming ultrasonic B-mode, Doppler, and strain images are analyzed and extended. The approach is based on a solution to the homogeneous wave equation for random inhomogeneous media. When the system is shift-variant, the spatial sensitivity function-defined as a spatial weighting function that determines the scattering volume for a fixed point of time-has advantages over the point-spread function traditionally used to analyze ultrasound systems. Spatial sensitivity functions are necessary for determining statistical moments in the context of rigorous image quality assessment, and they are time-reversed copies of point-spread functions for shift variant systems. A criterion is proposed to assess the validity of a local shift-invariance assumption. The analysis reveals realistic situations in which in-phase signals are correlated to the corresponding quadrature signals, which has strong implications for assessing lesion detectability. Also revealed is an opportunity to enhance near- and far-field spatial resolution by matched filtering unfocused beams. The analysis connects several well-known approaches to modeling ultrasonic echo signals.
- 9 July 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 50 (6) , 642-654
Linear system models for ultrasonic imaging: application to signal statistics
Linear equations for modeling echo signals from shift-variant systems forming ultrasonic B-mode, Doppler, and strain images are analyzed and extended. The approach is based on a solution to the homogeneous wave equation for random inhomogeneous media. When the system is shift-variant, the spatial sensitivity function-defined as a spatial weighting function that determines the scattering volume for a fixed point of time-has advantages over the point-spread function traditionally used to analyze ultrasound systems. Spatial sensitivity functions are necessary for determining statistical moments in the context of rigorous image quality assessment, and they are time-reversed copies of point-spread functions for shift variant systems. A criterion is proposed to assess the validity of a local shift-invariance assumption. The analysis reveals realistic situations in which in-phase signals are correlated to the corresponding quadrature signals, which has strong implications for assessing lesion detectability. Also revealed is an opportunity to enhance near- and far-field spatial resolution by matched filtering unfocused beams. The analysis connects several well-known approaches to modeling ultrasonic echo signals.
- 1 December 2001
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 110 (6) , 3243-3251
Ultrasonic properties of random media under uniaxial loading
Acoustic properties of two types of soft tissue-like media were measured as a function of compressive strain. Samples were subjected to uniaxial strains up to 40% along the axis of the transducer beam. Measurements were analyzed to test a common assumption made when using pulse-echo waveforms to track motion in soft tissues—that local properties of wave propagation and scattering are invariant under deformation. Violations of this assumption have implications for elasticity imaging procedures and could provide new opportunities for identifying the sources of backscatter in biological media such as breast parenchyma. We measured speeds of sound, attenuation coefficients, and echo spectra in compressed phantoms containing randomly positioned scatterers either stiffer or softer than the surrounding gelatin. Only the echo spectra of gel media with soft scatterers varied significantly during compression. Centroids of the echo spectra were found to be shifted to higher frequencies in proportion to the applied strain up to 10%, and increased monotonically up to 40% at a rate depending on the scatterer size. Centroid measurements were accurately modeled by assuming incoherent scattering from oblate spheroids with an eccentricity that increases with strain. While spectral shifts can be accurately modeled, recovery of lost echo coherence does not seem possible. Consequently, spectral variance during compression may ultimately limit the amount of strain that can be applied between two data fields in heterogeneous media such as lipid-filled tissues. It also appears to partially explain why strain images often produce greater echo decorrelation in tissues than in commonly used graphite–gelatin test phantoms.
- 1 December 2001
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 110 (6) , 3243-3251
Ultrasonic properties of random media under uniaxial loading
Acoustic properties of two types of soft tissue-like media were measured as a function of compressive strain. Samples were subjected to uniaxial strains up to 40% along the axis of the transducer beam. Measurements were analyzed to test a common assumption made when using pulse-echo waveforms to track motion in soft tissues—that local properties of wave propagation and scattering are invariant under deformation. Violations of this assumption have implications for elasticity imaging procedures and could provide new opportunities for identifying the sources of backscatter in biological media such as breast parenchyma. We measured speeds of sound, attenuation coefficients, and echo spectra in compressed phantoms containing randomly positioned scatterers either stiffer or softer than the surrounding gelatin. Only the echo spectra of gel media with soft scatterers varied significantly during compression. Centroids of the echo spectra were found to be shifted to higher frequencies in proportion to the applied strain up to 10%, and increased monotonically up to 40% at a rate depending on the scatterer size. Centroid measurements were accurately modeled by assuming incoherent scattering from oblate spheroids with an eccentricity that increases with strain. While spectral shifts can be accurately modeled, recovery of lost echo coherence does not seem possible. Consequently, spectral variance during compression may ultimately limit the amount of strain that can be applied between two data fields in heterogeneous media such as lipid-filled tissues. It also appears to partially explain why strain images often produce greater echo decorrelation in tissues than in commonly used graphite–gelatin test phantoms.
- 1 March 2000
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 107 (3) , 1421-1434
Maximum-likelihood approach to strain imaging using ultrasound
A maximum-likelihood (ML) strategy for strain estimation is presented as a framework for designing and evaluating bioelasticity imaging systems. Concepts from continuum mechanics, signal analysis, and acoustic scattering are combined to develop a mathematical model of the ultrasonic waveforms used to form strain images. The model includes three-dimensional (3-D) object motion described by affine transformations, Rayleigh scattering from random media, and 3-D system response functions. The likelihood function for these waveforms is derived to express the Fisher information matrix and variance bounds for displacement and strain estimation. The ML estimator is a generalized cross correlator for pre- and post-compression echo waveforms that is realized by waveform warping and filtering prior to cross correlation and peak detection. Experiments involving soft tissuelike media show the ML estimator approaches the Cramér–Rao error bound for small scaling deformations: at 5 MHz and 1.2% compression, the predicted lower bound for displacement errors is 4.4 μm and the measured standard deviation is 5.7 μm.
- 1 March 2000
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 107 (3) , 1421-1434
Maximum-likelihood approach to strain imaging using ultrasound
A maximum-likelihood (ML) strategy for strain estimation is presented as a framework for designing and evaluating bioelasticity imaging systems. Concepts from continuum mechanics, signal analysis, and acoustic scattering are combined to develop a mathematical model of the ultrasonic waveforms used to form strain images. The model includes three-dimensional (3-D) object motion described by affine transformations, Rayleigh scattering from random media, and 3-D system response functions. The likelihood function for these waveforms is derived to express the Fisher information matrix and variance bounds for displacement and strain estimation. The ML estimator is a generalized cross correlator for pre- and post-compression echo waveforms that is realized by waveform warping and filtering prior to cross correlation and peak detection. Experiments involving soft tissuelike media show the ML estimator approaches the Cramér–Rao error bound for small scaling deformations: at 5 MHz and 1.2% compression, the predicted lower bound for displacement errors is 4.4 μm and the measured standard deviation is 5.7 μm.
- 1 January 2000
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 3 (2) , 109-118
Finite-Difference Time-Domain Simulator for Half-Space Bioacoustic Problems
The finite-difference time-domain (FDTD) method provides a numerical technique for solving acoustic forward problems. The FDTD is particularly useful in geometries that encompass heterogeneities. Plane-wave modeling permits the simulation of many practical bioacoustic problems because the phase front in the focal zone of many acoustic transducers is nearly planar. The formulation presented in this paper provides a technique for solving half-space problems under local plane-wave illumination.
- 1 January 2000
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 3 (2) , 109-118
Finite-Difference Time-Domain Simulator for Half-Space Bioacoustic Problems
The finite-difference time-domain (FDTD) method provides a numerical technique for solving acoustic forward problems. The FDTD is particularly useful in geometries that encompass heterogeneities. Plane-wave modeling permits the simulation of many practical bioacoustic problems because the phase front in the focal zone of many acoustic transducers is nearly planar. The formulation presented in this paper provides a technique for solving half-space problems under local plane-wave illumination.
- 1 July 1998
- Published by Wiley in Medical Physics
- Vol. 25 (7) , 1132-1138
Comparison of a cathode-ray-tube and film for display of computed radiographic images
- 1 July 1998
- Published by Wiley in Medical Physics
- Vol. 25 (7) , 1132-1138
Comparison of a cathode-ray-tube and film for display of computed radiographic images
- 7 April 1997
- Published by Elsevier in Journal of Theoretical Biology
- Vol. 185 (3) , 357-365
Mathematical Model of Progressive Renal Disease
- 7 April 1997
- Published by Elsevier in Journal of Theoretical Biology
- Vol. 185 (3) , 357-365
Mathematical Model of Progressive Renal Disease