Maotian Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Maotian Xu has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
Yuanqiang Hao
Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu, China
8 shared publicationsPeng Qu
Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu 476000, Henan, PR China
7 shared publicationsXu Zhu
Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu 476000, China
6 shared publicationsYanli Zhou
Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, Shangqiu Normal University, Shangqiu, China
6 shared publications- Baoxia Liu
Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu 476000, China
4 shared publications Fenghua Geng
Henan Key Laboratory Cultivation Base of Nanobiological Analytical Chemistry, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu 476000, China
4 shared publications
Latest Publications
- 20 February 2021
- Published by Springer Nature in Journal of Analysis and Testing
- Vol. 5 (4) , 360-369
Quantifying Hypochlorous Acid Concentration in Environmental Water Using Smartphone Colorimetry
- 20 February 2021
- Published by Springer Nature in Journal of Analysis and Testing
- Vol. 5 (4) , 360-369
Quantifying Hypochlorous Acid Concentration in Environmental Water Using Smartphone Colorimetry
- 1 January 2020
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 75 (1) , 111-118
Sensitive Voltammetric Sensor for Evaluation of trans-resveratrol Levels in Wines based on Poly(L-lysine) Modified Electrode
A novel, economic, and highly sensitive electrochemical sensor for the determination of trans-resveratrol (RES) was fabricated by electropolymerization of poly(L-lysine) films onto glassy carbon electrode (GCE) surface. The electrochemical behavior of RES in Britton–Robinson buffer solution (pH 2.0) on the poly(L-lysine)/GCE was investigated by cyclic voltammetry and linear sweep voltammetry for the first time. Results showed that the detection range of the proposed sensor to RES was from 0.20 to 12.0 μM with the minimum detectable concentration of 0.06 μM. The reported electrochemical sensor also exhibited high selectivity, good reproducibility, and long-term stability for RES detection. In addition, the proposed method can be employed for the determination of RES in red wines with satisfactory results. The proposed electrochemical strategy presents valuable information related to evaluation of RES levels in real samples.
- 1 January 2020
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 75 (1) , 111-118
Sensitive Voltammetric Sensor for Evaluation of trans-resveratrol Levels in Wines based on Poly(L-lysine) Modified Electrode
A novel, economic, and highly sensitive electrochemical sensor for the determination of trans-resveratrol (RES) was fabricated by electropolymerization of poly(L-lysine) films onto glassy carbon electrode (GCE) surface. The electrochemical behavior of RES in Britton–Robinson buffer solution (pH 2.0) on the poly(L-lysine)/GCE was investigated by cyclic voltammetry and linear sweep voltammetry for the first time. Results showed that the detection range of the proposed sensor to RES was from 0.20 to 12.0 μM with the minimum detectable concentration of 0.06 μM. The reported electrochemical sensor also exhibited high selectivity, good reproducibility, and long-term stability for RES detection. In addition, the proposed method can be employed for the determination of RES in red wines with satisfactory results. The proposed electrochemical strategy presents valuable information related to evaluation of RES levels in real samples.
- 1 March 2019
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 210, 381-386
A coumarin-based fluorescent probe for ratiometric detection of hydrazine and its application in living cells
- 1 March 2019
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 210, 381-386
A coumarin-based fluorescent probe for ratiometric detection of hydrazine and its application in living cells
- 1 September 2017
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 184, 355-360
A highly selective long-wavelength fluorescent probe for hydrazine and its application in living cell imaging
- 1 September 2017
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 184, 355-360
A highly selective long-wavelength fluorescent probe for hydrazine and its application in living cell imaging
- Open Access
- 11 October 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 35186
Fabrication of an antibody-aptamer sandwich assay for electrochemical evaluation of levels of β-amyloid oligomers
Amyloid β-peptide (Aβ) in its oligomeric form is often considered as the most toxic species in Alzheimer’s disease (AD), and thus Aβ oligomer is a potentially promising candidate biomarker for AD diagnosis. The development of a sensitive and reliable method for monitoring the Aβ oligomer levels in body fluids is an urgent requirement in order to predict the severity and progression at early or preclinical stages of AD. Here, we show a proof of concept for a sensitive and specific detection of Aβ oligomers by an antibody-aptamer sandwich assay. The antibodies of Aβ oligomers and a nanocomposite of gold nanoparticles with aptamer and thionine (aptamer-Au-Th) were used as the recognition element and the detection probe for specifically binding to Aβ oligomers, respectively. The electrochemical signal of Th reduction could provide measurable electrochemical signals, and a low limit of detection (100 pM) was achieved due to the signal amplification by high loading of Th on the gold nanoparticles. The feasibility of the assay was verified by test of Aβ oligomers in artificial cerebrospinal fluid. The proposed strategy presents valuable information related to early diagnosis of AD process.
- 11 October 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 35186
Open AccessFabrication of an antibody-aptamer sandwich assay for electrochemical evaluation of levels of β-amyloid oligomers
Amyloid β-peptide (Aβ) in its oligomeric form is often considered as the most toxic species in Alzheimer’s disease (AD), and thus Aβ oligomer is a potentially promising candidate biomarker for AD diagnosis. The development of a sensitive and reliable method for monitoring the Aβ oligomer levels in body fluids is an urgent requirement in order to predict the severity and progression at early or preclinical stages of AD. Here, we show a proof of concept for a sensitive and specific detection of Aβ oligomers by an antibody-aptamer sandwich assay. The antibodies of Aβ oligomers and a nanocomposite of gold nanoparticles with aptamer and thionine (aptamer-Au-Th) were used as the recognition element and the detection probe for specifically binding to Aβ oligomers, respectively. The electrochemical signal of Th reduction could provide measurable electrochemical signals, and a low limit of detection (100 pM) was achieved due to the signal amplification by high loading of Th on the gold nanoparticles. The feasibility of the assay was verified by test of Aβ oligomers in artificial cerebrospinal fluid. The proposed strategy presents valuable information related to early diagnosis of AD process.
- 26 September 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (103) , 100743-100747
Turn-on fluorescence detection of ciprofloxacin in tablets based on lanthanide coordination polymer nanoparticles
Metal–organic coordination polymers (MOCPs) have emerged as a new family of functional nanomaterials. Here, we report a facile and effective fluorescence method for detecting CIP in tablets using a kind of lanthanide coordination polymer nanoparticle (LCPNP), specifically Eu/GMP NPs, as the sensing platform. Eu/GMP NPs, composed of guanosine monophosphate (GMP) and europium (Eu3+) ion, are by themselves non-luminescent. The addition of ciprofloxacin (CIP) into the Eu/GMP NPs, however, noticeably enhanced their fluorescence due to the strong coordination interaction between CIP and Eu3+, and the improved hydrophobic interior of the LCPNPs resulted in an efficient energy transfer from CIP to Eu3+. The fluorescence intensity of Eu/GMP at 615 nm showed a linear relationship with CIP concentration between 1.0 and 40 μM, with a detection limit of 780 nM. We believe that the proposed time-resolved fluorometric assay based on the Eu/GMP NP lanthanide nanosensor, with its long fluorescence lifetime, has a great potential for using in the testing of biosamples.
- 26 September 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (103) , 100743-100747
Turn-on fluorescence detection of ciprofloxacin in tablets based on lanthanide coordination polymer nanoparticles
Metal–organic coordination polymers (MOCPs) have emerged as a new family of functional nanomaterials. Here, we report a facile and effective fluorescence method for detecting CIP in tablets using a kind of lanthanide coordination polymer nanoparticle (LCPNP), specifically Eu/GMP NPs, as the sensing platform. Eu/GMP NPs, composed of guanosine monophosphate (GMP) and europium (Eu3+) ion, are by themselves non-luminescent. The addition of ciprofloxacin (CIP) into the Eu/GMP NPs, however, noticeably enhanced their fluorescence due to the strong coordination interaction between CIP and Eu3+, and the improved hydrophobic interior of the LCPNPs resulted in an efficient energy transfer from CIP to Eu3+. The fluorescence intensity of Eu/GMP at 615 nm showed a linear relationship with CIP concentration between 1.0 and 40 μM, with a detection limit of 780 nM. We believe that the proposed time-resolved fluorometric assay based on the Eu/GMP NP lanthanide nanosensor, with its long fluorescence lifetime, has a great potential for using in the testing of biosamples.
- 1 August 2016
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 165, 150-154
A water-soluble and retrievable ruthenium-based probe for colorimetric recognition of Hg(II) and Cys
- 1 August 2016
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 165, 150-154
A water-soluble and retrievable ruthenium-based probe for colorimetric recognition of Hg(II) and Cys