DMDavid L. McGlasson

David L. McGlasson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David L. McGlasson has a total of 1 co-authors. Here are the top co-authors by number of shared publications:

  • George A. Fritsma

    Laboratory Medicine, University of Alabama at Birmingham, Birmingham, Alabama

    1 shared publication

Latest Publications

  • Comparison of Six Dilute Russell Viper Venom Time Lupus Anticoagulant Screen/Confirm Assay Kits

    by George A. Fritsma, David L. McGlasson

    Background The normalized dilute Russell viper venom time (DRVVT) ratio provides a robust assay methodology for lupus anticoagulant (LA) detection. Objectives We evaluated six normalized DRVVT LA screen and confirm systems for inter-method consistency. Reagents were purchased from Diagnostica Stago, Inc. (Parsippany, NJ); Precision BioLogic Inc. (Halifax, Nova Scotia, Canada); Siemens Healthcare Inc. (Deerfield, IL); TCoag (Parsippany, NJ); Instrumentation Laboratories (Bedford, MA); and Sekisui Diagnostics (Pfungstadt, Germany). Methods For all assays, we employed the STA-R Evolution automated coagulometer, adhering to manufacturers' instructions. LA-positive and LA-negative plasma controls were purchased from Diagnostica Stago and pooled normal plasma (PNP) was purchased from Precision BioLogic. We computed the mean of the reference interval (MRI) and action limits for all kits using LA-negative aliquots from locally sourced normal subjects (n = 42). We then assayed locally sourced LA-positive plasmas (n = 43) and using analysis of variance compared uncorrected screen/confirm ratios and screen/confirm ratios that were normalized using MRI and mean PNP results. Results The grand mean action limit, MRI + 3 SD, derived from the local normal plasmas, was 1.2, confirming the manufacturers' recommended limits; however, limits must be locally computed. The all-sample p value was less than 0.001, indicating heterogeneity among ratios. When Sekisui ratios were excluded, the p value was 0.14, thus indicating that this method introduced the major difference among methods. Mean screen/confirm ratios computed from LA-positive specimens were 1.91 to 2.04 for reagent systems other than Sekisui, which instead yielded a mean ratio of 1.198, indicating that this method was relatively insensitive to LA. A negative bias was recorded by two lots from the Sekisui system for LA-positive specimens. Screen/confirm ratios from combined LA-positive and LA-negative samples generated a combined range of 1.59 to 1.67 for all reagents except Sekisui, which instead yielded 1.09. The within-run percent coefficient of variation (CV%) was less than 5.0% using all samples. Between-run CV% using Diagnostica Stago LA-positive and LA-negative controls was less than 5.5%. Conclusions DRVVT screen/confirm ratios discriminate between LA-positive and LA-negative samples and generally provide acceptable reproducibility. Ratio results may vary among reagent–instrument combinations. In this study, normalization added little to the clinical result interpretation.


  • Monitoring Coumadin-The Original Oral Anticoagulant

    by David L. McGlasson

    Tissue factor (TF) in vivo activates the coagulation cascade through the formation of the TF/FVIIa complex. The PT adds a TF/calcium mixture to citrated platelet-poor-plasma (PPP) in vitro to obtain the time for clot formation. There are many variables such as proper specimen collection, multiple reagent/instrument combinations and, most importantly, the sources of thromboplastin, usually rabbit and recombinant tissue factor, selected for the assay.1,2


  • Open Access

    Career Research Opportunities for the Medical Laboratory Scientist

    by David L. McGlasson

    Medical Laboratory Scientists (MLS) typically practice in hospital laboratories; however there are multiple alternatives in research. This article details the advantages of working in a variety of research laboratory settings. These include public institutions, federal laboratory workplaces, private facilities, and industry settings. A view of the different research laboratory settings such as public institutions, federal laboratory workplaces, private facilities, and industry settings will be provided. An assessment on how MLS professionals can prepare for a career in research is outlined and the report concludes with a brief summary of the various aspects of the research setting.