Hywel Davies
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hywel Davies has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
J. Foote
Department of Orthopaedics, Weston General Hospital, Weston-Super-Mare, Somerset - UK
2 shared publicationsAndrew Unwin
1 shared publicationG.H. Slater
The Minimal Access Therapy Training Unit, The Royal Surrey County Hospital, Egerton Road, Guildford, Surrey GU7 5XX, England
1 shared publicationM. Bailey
The Minimal Access Therapy Training Unit, The Royal Surrey County Hospital, Egerton Road, Guildford, Surrey GU7 5XX, England
1 shared publicationPaul Aichroth
1 shared publicationR.F. Spencer
Department of Orthopaedics, Weston General Hospital, Weston-Super-Mare, Somerset - UK
1 shared publication
Latest Publications
- 1 July 2007
- Published by SAGE Publications in HIP International
- Vol. 17 (3) , 155-159
Accuracy of Femoral Templating in Reproducing Anatomical Femoral Offset in Total Hip Replacement
Restoration of hip biomechanics is a crucial component of successful total hip replacement. Preoperative templating is recommended to ensure that the size and orientation of implants is optimised. We studied how closely natural femoral offset could be reproduced using the manufacturers' templates for 10 femoral stems in common use in the UK. A series of 23 consecutive preoperative radiographs from patients who had undergone unilateral total hip replacement for unilateral osteoarthritis of the hip was employed. The change in offset between the templated position of the best-fitting template and the anatomical centre of the hip was measured. The templates were then ranked according to their ability to reproduce the normal anatomical offset. The most accurate was the CPS-Plus (Root Mean Square Error 2.0 mm) followed in rank order by: C stem (2.16), CPT (2.40), Exeter (3.23), Stanmore (3.28), Charnley (3.65), Corail (3.72), ABG II (4.30), Furlong HAC (5.08) and Furlong modular (7.14). A similar pattern of results was achieved when the standard error of variability of offset was analysed. We observed a wide variation in the ability of the femoral prosthesis templates to reproduce normal femoral offset. This variation was independent of the seniority of the observer. The templates of modern polished tapered stems with high modularity were best able to reproduce femoral offset. The current move towards digitisation of X-rays may offer manufacturers an opportunity to improve template designs in certain instances, and to develop appropriate computer software.
- 1 July 2007
- Published by SAGE Publications in HIP International
- Vol. 17 (3) , 155-159
Accuracy of Femoral Templating in Reproducing Anatomical Femoral Offset in Total Hip Replacement
Restoration of hip biomechanics is a crucial component of successful total hip replacement. Preoperative templating is recommended to ensure that the size and orientation of implants is optimised. We studied how closely natural femoral offset could be reproduced using the manufacturers' templates for 10 femoral stems in common use in the UK. A series of 23 consecutive preoperative radiographs from patients who had undergone unilateral total hip replacement for unilateral osteoarthritis of the hip was employed. The change in offset between the templated position of the best-fitting template and the anatomical centre of the hip was measured. The templates were then ranked according to their ability to reproduce the normal anatomical offset. The most accurate was the CPS-Plus (Root Mean Square Error 2.0 mm) followed in rank order by: C stem (2.16), CPT (2.40), Exeter (3.23), Stanmore (3.28), Charnley (3.65), Corail (3.72), ABG II (4.30), Furlong HAC (5.08) and Furlong modular (7.14). A similar pattern of results was achieved when the standard error of variability of offset was analysed. We observed a wide variation in the ability of the femoral prosthesis templates to reproduce normal femoral offset. This variation was independent of the seniority of the observer. The templates of modern polished tapered stems with high modularity were best able to reproduce femoral offset. The current move towards digitisation of X-rays may offer manufacturers an opportunity to improve template designs in certain instances, and to develop appropriate computer software.
- 1 January 2007
- Published by SAGE Publications in HIP International
- Vol. 17 (3) , 155-159
Accuracy of femoral templating in reproducing anatomical femoral offset in total hip replacement
- 1 January 2007
- Published by SAGE Publications in HIP International
- Vol. 17 (3) , 155-159
Accuracy of femoral templating in reproducing anatomical femoral offset in total hip replacement
- 1 January 2003
- Published by Springer Nature in Surgical Endoscopy
- Vol. 17 (1) , 160-161
Laparascopic sigmoid colectomy for diverticular disease in a patient with situs inversus
We present the case of a 50-year-old man with situs inversus who underwent laprascopic colonic resection for diverticulitis. The patient, who had right-sided pain due to inversion of the viscera mimicking appendicitis, initially presented a diagnostic challenge. A barium meal confirmed situs inversus and the diagnosis of diverticulitis. We present an overview of the operative technique of what is the first documented laparoscopic colectemy in a patient with situs inversus. We then discuss the benefits of the laproscopic approach to colectomy, with reference to this interesting case with unusual anatomy.
- 1 January 2003
- Published by Springer Nature in Surgical Endoscopy
- Vol. 17 (1) , 160-161
Laparascopic sigmoid colectomy for diverticular disease in a patient with situs inversus
We present the case of a 50-year-old man with situs inversus who underwent laprascopic colonic resection for diverticulitis. The patient, who had right-sided pain due to inversion of the viscera mimicking appendicitis, initially presented a diagnostic challenge. A barium meal confirmed situs inversus and the diagnosis of diverticulitis. We present an overview of the operative technique of what is the first documented laparoscopic colectemy in a patient with situs inversus. We then discuss the benefits of the laproscopic approach to colectomy, with reference to this interesting case with unusual anatomy.