Christian F. Poets
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Christian F. Poets has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Bettina Bohnhorst
Department of Neonatology and Pediatric Pulmonology, Hannover Medical School, Hannover, Germany
3 shared publicationsAnne Rudolph
Department of Paediatric Pulmonology, Hannover Medical School, Hannover, Germany
1 shared publicationB Bohnhorst
Department of Neonatology and Paediatric Pulmonology, Medical School, Hannover, Germany
1 shared publicationB. Bohnhorst
Department of Paediatric Pulmonology, Medizinische Hochschule Hannover, D-30623 Hannover, Germany Tel.: +49-511-532 9124, Fax: +49-511-532 3895
1 shared publicationBrigitte Sens
Lower Saxony Perinatal Working Group, Hannover, Germany
1 shared publicationC. S. Peter
Department of Paediatric Pulmonology, Medizinische Hochschule Hannover, Germany
1 shared publication
Latest Publications
- 20 September 2006
- Published by Wiley in Pediatric Pulmonology
- Vol. 41 (11) , 1025-1039
Molecular and functional changes of pulmonary surfactant in response to hyperoxia
Surfactant comprises phosphatidylcholine (PC) together with anionic phospholipids, neutral lipids, and surfactant proteins SP-A to-D. Its composition is highly specific, with dipalmitoyl-PC, palmitoyl-myristoyl-PC, and palmitoyl-palmitoleoyl-PC as its predominant PC species, but with low polyunsaturated phospholipids. Changes in pulmonary metabolism and function in response to injuries depend on their duration and whether adaptation can occur. We examined in rats prolonged (7 days) versus acute (2 days) exposure to non-lethal oxygen concentrations (85%) with respect to the composition and metabolism of individual lung phospholipid molecular species. Progressive inflammation, structural alteration, and involvement of type II pneumocytes were confirmed by augmented bromodeoxyuridine incorporation, broadening of alveolar septa, and increased granulocyte, macrophage, SP-A, and SP-D concentrations. Surfactant function was impaired after 2 days, but normalized with duration of hyperoxia, which was attributable to inhibition but not to alteration in SP-B/C concentrations. Phospholipid pool sizes and PC synthesis by lung tissue, as assessed by [methyl-3H]-choline incorporation, were unchanged after 2 days, although after 7 days they were elevated 1.7-fold. By contrast, incorporation of labeled PC into tissue pools of surfactant and lung lavage fluid decreased progressively. Moreover, concentrations of arachidonic acid containing phospholipids were augmented at the expense of saturated palmitoyl-myristoyl-PC and dipalmitoyl-PC. We conclude a persisting impairment in the intracellular trafficking and secretion of newly synthesized PC, accompanied by a progressive increase in alveolar arachidonic acid containing phospholipids in spite of recovery of acutely impaired surfactant function and adaptive increase of overall PC synthesis. Pediatr Pulmonol. 2006, 41:1025–1039.
- 20 September 2006
- Published by Wiley in Pediatric Pulmonology
- Vol. 41 (11) , 1025-1039
Molecular and functional changes of pulmonary surfactant in response to hyperoxia
Surfactant comprises phosphatidylcholine (PC) together with anionic phospholipids, neutral lipids, and surfactant proteins SP-A to-D. Its composition is highly specific, with dipalmitoyl-PC, palmitoyl-myristoyl-PC, and palmitoyl-palmitoleoyl-PC as its predominant PC species, but with low polyunsaturated phospholipids. Changes in pulmonary metabolism and function in response to injuries depend on their duration and whether adaptation can occur. We examined in rats prolonged (7 days) versus acute (2 days) exposure to non-lethal oxygen concentrations (85%) with respect to the composition and metabolism of individual lung phospholipid molecular species. Progressive inflammation, structural alteration, and involvement of type II pneumocytes were confirmed by augmented bromodeoxyuridine incorporation, broadening of alveolar septa, and increased granulocyte, macrophage, SP-A, and SP-D concentrations. Surfactant function was impaired after 2 days, but normalized with duration of hyperoxia, which was attributable to inhibition but not to alteration in SP-B/C concentrations. Phospholipid pool sizes and PC synthesis by lung tissue, as assessed by [methyl-3H]-choline incorporation, were unchanged after 2 days, although after 7 days they were elevated 1.7-fold. By contrast, incorporation of labeled PC into tissue pools of surfactant and lung lavage fluid decreased progressively. Moreover, concentrations of arachidonic acid containing phospholipids were augmented at the expense of saturated palmitoyl-myristoyl-PC and dipalmitoyl-PC. We conclude a persisting impairment in the intracellular trafficking and secretion of newly synthesized PC, accompanied by a progressive increase in alveolar arachidonic acid containing phospholipids in spite of recovery of acutely impaired surfactant function and adaptive increase of overall PC synthesis. Pediatr Pulmonol. 2006, 41:1025–1039.
- 1 January 2002
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 109 (1) , 8-11
Gastroesophageal Reflux and Apnea of Prematurity: No Temporal Relationship
Objective. A relationship between gastroesophageal reflux (GER) and apnea of prematurity (AOP) has long been suspected but is difficult to prove because most GER in this age group is nonacidic and thus undetectable by pH monitoring, the current standard for GER detection. The new multiple intraluminal impedance (MII) technique allows pH-independent reflux detection via changes in impedance caused by a liquid bolus inside the esophagus. We used this technique to investigate whether there is a temporal relationship between GER and AOP and whether GER occurs predominantly before a cardiorespiratory (CR) event. Methods. Nineteen infants with AOP (median gestational age at birth: 30 weeks; range: 24–34; age at study: 26 days [13–93]) underwent 20 6-hour recordings of MII, breathing movements, nasal airflow, electrocardiogram, pulse oximeter saturation, and pulse waveforms. MII signals were analyzed, independent of CR signals, for reflux episodes (RE), defined as a fall in impedance in at least the 2 most distal channels. CR signals were analyzed for CR events, ie, apneas of ≥4-second duration, desaturations to ≤80%, and falls in heart rate to ≤100/min. A temporal relationship between an RE and a CR event was considered present if both commenced within 20 seconds of each other. Results. There were 2039 apneas (median: 67; range: 10–346), 188 desaturations (6; 0–25), 44 bradycardias (0; 0–24), and 524 RE (25; 8–62). The frequency of apnea occurring within ± 20 seconds of an RE was not significantly different from that during reflux-free epochs (0.19/min [0.00–0.85] vs 0.25/min [0.00–1.15]); the same was true for desaturations and bradycardias. Also, RE occurred similarly often within 20 seconds before as after an apnea (2; 0–14 vs 1; 0–17). A minority of apneas (3.5%) was associated with an RE reaching the pharyngeal level; of these, significantly more (45 vs 26; median: 1; 0–10 vs 1; 0–7) occurred after rather than before an RE. Conclusion. Both CR events and GER were common in these infants but, with few exceptions, did not seem to be temporally related.
- 1 January 2002
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 109 (1) , 8-11
Gastroesophageal Reflux and Apnea of Prematurity: No Temporal Relationship
Objective. A relationship between gastroesophageal reflux (GER) and apnea of prematurity (AOP) has long been suspected but is difficult to prove because most GER in this age group is nonacidic and thus undetectable by pH monitoring, the current standard for GER detection. The new multiple intraluminal impedance (MII) technique allows pH-independent reflux detection via changes in impedance caused by a liquid bolus inside the esophagus. We used this technique to investigate whether there is a temporal relationship between GER and AOP and whether GER occurs predominantly before a cardiorespiratory (CR) event. Methods. Nineteen infants with AOP (median gestational age at birth: 30 weeks; range: 24–34; age at study: 26 days [13–93]) underwent 20 6-hour recordings of MII, breathing movements, nasal airflow, electrocardiogram, pulse oximeter saturation, and pulse waveforms. MII signals were analyzed, independent of CR signals, for reflux episodes (RE), defined as a fall in impedance in at least the 2 most distal channels. CR signals were analyzed for CR events, ie, apneas of ≥4-second duration, desaturations to ≤80%, and falls in heart rate to ≤100/min. A temporal relationship between an RE and a CR event was considered present if both commenced within 20 seconds of each other. Results. There were 2039 apneas (median: 67; range: 10–346), 188 desaturations (6; 0–25), 44 bradycardias (0; 0–24), and 524 RE (25; 8–62). The frequency of apnea occurring within ± 20 seconds of an RE was not significantly different from that during reflux-free epochs (0.19/min [0.00–0.85] vs 0.25/min [0.00–1.15]); the same was true for desaturations and bradycardias. Also, RE occurred similarly often within 20 seconds before as after an apnea (2; 0–14 vs 1; 0–17). A minority of apneas (3.5%) was associated with an RE reaching the pharyngeal level; of these, significantly more (45 vs 26; median: 1; 0–10 vs 1; 0–7) occurred after rather than before an RE. Conclusion. Both CR events and GER were common in these infants but, with few exceptions, did not seem to be temporally related.
- 1 January 2002
- Vol. 94, S41-3
Pulse oximetry in the neonatal intensive care unit (NICU): detection of hyperoxemia and false alarm rates.
- 1 January 2002
- Vol. 94, S41-3
Pulse oximetry in the neonatal intensive care unit (NICU): detection of hyperoxemia and false alarm rates.
- 10 March 2000
- Vol. 112 (5) , 198-203
[Home monitoring of infants at risk of sudden infant death: suggestions for reconsideration of current practice].
Considering the decreasing incidence of sudden infant death syndrome (SIDS) and the yet unproven efficacy of home monitoring, current indications for home monitoring should be reconsidered. Documented monitoring still appears to be necessary in infants with apparent life-threatening events (ALTE) and in siblings of two or more SIDS victims. Home monitoring is also indicated in infants on home oxygen/ventilation or with specific respiratory control disorders, but is usually not indicated in asymptomatic preterm infants or in those with a single SIDS sibling, a mother indulging in drug abuse, or increased parental anxiety. The risk of SIDS in these groups is lower than that in infants of mothers who are heavy smokers, who are nowhere regarded as candidates for home monitoring. If monitoring is considered necessary, new generation pulse oximeters with low false alarm rates are probably the safest technical option because they sound the alarm comparatively early, yet do not give too many false alarms. Home monitor recommendations should be revisited, taking the above issues into account.
- 10 March 2000
- Vol. 112 (5) , 198-203
[Home monitoring of infants at risk of sudden infant death: suggestions for reconsideration of current practice].
Considering the decreasing incidence of sudden infant death syndrome (SIDS) and the yet unproven efficacy of home monitoring, current indications for home monitoring should be reconsidered. Documented monitoring still appears to be necessary in infants with apparent life-threatening events (ALTE) and in siblings of two or more SIDS victims. Home monitoring is also indicated in infants on home oxygen/ventilation or with specific respiratory control disorders, but is usually not indicated in asymptomatic preterm infants or in those with a single SIDS sibling, a mother indulging in drug abuse, or increased parental anxiety. The risk of SIDS in these groups is lower than that in infants of mothers who are heavy smokers, who are nowhere regarded as candidates for home monitoring. If monitoring is considered necessary, new generation pulse oximeters with low false alarm rates are probably the safest technical option because they sound the alarm comparatively early, yet do not give too many false alarms. Home monitor recommendations should be revisited, taking the above issues into account.
- 1 January 2000
- Published by Wiley in Acta Paediatrica
- Vol. 89 (5) , 571-576
False alarms in very low birthweight infants: comparison between three intensive care monitoring systems
Monitor alarms are a major burden on both patients and staff in intensive care units. We compared alarm rates from three different monitor systems (Hewlett Packard (HP), Kontron Instruments (KI), Marquette-Hellige (MH)) in a tertiary neonatal intensive care unit. Monitors were used in random order on three consecutive days over 8h each in 16 preterm infants (median gestational age at birth 29 wk (range 24-34), age at study 18 d (8-53), weight at study 1160g (595-1430)). Alarms were classified as true or false using flow sheets based on continuous observation of both the patient and related parameters. There was one alarm every 9 min of monitoring. The median number of true alarms did not differ significantly between systems, being 28 per 8 h (range 9-87) for HP, 26 (3-81) for KI, and 30 (5-135) for MH. The median number of false alarms differed widely, with the HP system generating 32 (7-77) such alarms per 8 h, compared to 8 (0-19) for KI and 15 (2-32) for MH (p < 0.01 HP vs KI and MH, p lt; 0.05 KI vs MH). These differences between systems were mainly due to differences in pulse oximeter and transcutaneous PO2 monitor alarm rates. Conclusions: In conclusion, this study shows marked differences between both parameters and manufacturers in the frequency with which false alarms occur. It may provide a basis from which reductions in alarm rates can be sought.
- 1 January 2000
- Published by Wiley in Acta Paediatrica
- Vol. 89 (5) , 571-576
False alarms in very low birthweight infants: comparison between three intensive care monitoring systems
Monitor alarms are a major burden on both patients and staff in intensive care units. We compared alarm rates from three different monitor systems (Hewlett Packard (HP), Kontron Instruments (KI), Marquette-Hellige (MH)) in a tertiary neonatal intensive care unit. Monitors were used in random order on three consecutive days over 8h each in 16 preterm infants (median gestational age at birth 29 wk (range 24-34), age at study 18 d (8-53), weight at study 1160g (595-1430)). Alarms were classified as true or false using flow sheets based on continuous observation of both the patient and related parameters. There was one alarm every 9 min of monitoring. The median number of true alarms did not differ significantly between systems, being 28 per 8 h (range 9-87) for HP, 26 (3-81) for KI, and 30 (5-135) for MH. The median number of false alarms differed widely, with the HP system generating 32 (7-77) such alarms per 8 h, compared to 8 (0-19) for KI and 15 (2-32) for MH (p < 0.01 HP vs KI and MH, p lt; 0.05 KI vs MH). These differences between systems were mainly due to differences in pulse oximeter and transcutaneous PO2 monitor alarm rates. Conclusions: In conclusion, this study shows marked differences between both parameters and manufacturers in the frequency with which false alarms occur. It may provide a basis from which reductions in alarm rates can be sought.
- 3 September 1999
- Published by S. Karger AG in Neonatology
- Vol. 76 (4) , 207-213
Effect of Doxapram on Episodes of Apnoea, Bradycardia and Hypoxaemia in Preterm Infants
Aim: To study the effect of doxapram on the frequency of apnoea, bradycardia and hypoxaemia. Methods: Fifteen infants, median gestational age at birth 27 weeks (range 24–30), age at study 27 days (12–60), with ≥6 episodes of bradycardia or hypoxaemia/6 h despite serum caffeine levels in the therapeutic range, received doxapram either intravenously (0.5–2 mg/kg/h) or orally (2–8 mg/kg every 2 h). Six-hour recordings of pulse oximeter saturation (SPO2), pulse waveforms, ECG, breathing movements and nasal airflow were performed immediately before as well as 1, 3 and 6 days after onset of treatment. Recordings were analysed for apnoea (≥4 s), bradycardia (heart rate < 2/3 of baseline) and hypoxaemia (SPO2 ≤80%). Results: There was no difference between enteral and intravenous administration; results are therefore presented for the total group. Doxapram resulted in a significant decrease in the frequency of apnoea [22 (11–27) vs. 14 (7–23)/h, p < 0.01], bradycardia [3 (0–7) vs. 1 (0–3)/h, p < 0.01] and hypoxaemia [8 (0–18) vs. 2 (0– 17)/h, p < 0.01] already after 1 day of treatment, which was sustained throughout the 6-day study period. Side effects included an increase in the proportion of time spent awake [5 (0–24) vs. 12% (3–28), p < 0.01] and in gastric residuals [0% of feeding volume (0–5) vs. 4% (0–19), p < 0.05]. Enteral was switched to intravenous doxapram in 3 of 9 infants because of gastrointestinal side effects. Conclusion: Doxapram substantially reduced the frequency of apnoea, bradycardia and hypoxaemia in these patients with caffeine-resistant apnoea of prematurity. Enteral administration, however, was not tolerated in a significant proportion (33%) of infants.
- 3 September 1999
- Published by S. Karger AG in Neonatology
- Vol. 76 (4) , 207-213
Effect of Doxapram on Episodes of Apnoea, Bradycardia and Hypoxaemia in Preterm Infants
Aim: To study the effect of doxapram on the frequency of apnoea, bradycardia and hypoxaemia. Methods: Fifteen infants, median gestational age at birth 27 weeks (range 24–30), age at study 27 days (12–60), with ≥6 episodes of bradycardia or hypoxaemia/6 h despite serum caffeine levels in the therapeutic range, received doxapram either intravenously (0.5–2 mg/kg/h) or orally (2–8 mg/kg every 2 h). Six-hour recordings of pulse oximeter saturation (SPO2), pulse waveforms, ECG, breathing movements and nasal airflow were performed immediately before as well as 1, 3 and 6 days after onset of treatment. Recordings were analysed for apnoea (≥4 s), bradycardia (heart rate < 2/3 of baseline) and hypoxaemia (SPO2 ≤80%). Results: There was no difference between enteral and intravenous administration; results are therefore presented for the total group. Doxapram resulted in a significant decrease in the frequency of apnoea [22 (11–27) vs. 14 (7–23)/h, p < 0.01], bradycardia [3 (0–7) vs. 1 (0–3)/h, p < 0.01] and hypoxaemia [8 (0–18) vs. 2 (0– 17)/h, p < 0.01] already after 1 day of treatment, which was sustained throughout the 6-day study period. Side effects included an increase in the proportion of time spent awake [5 (0–24) vs. 12% (3–28), p < 0.01] and in gastric residuals [0% of feeding volume (0–5) vs. 4% (0–19), p < 0.05]. Enteral was switched to intravenous doxapram in 3 of 9 infants because of gastrointestinal side effects. Conclusion: Doxapram substantially reduced the frequency of apnoea, bradycardia and hypoxaemia in these patients with caffeine-resistant apnoea of prematurity. Enteral administration, however, was not tolerated in a significant proportion (33%) of infants.
- 1 January 1999
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 158 (1) , 67-70
Necrotising enterocolitis: is there a relationship to specific pathogens?
Outbreaks of necrotising enterocolitis (NEC) have often been related to specific pathogens such as Enterobacteriaceae. This relationship, however, remains uncertain because of the retrospective nature of the studies addressing this issue. We performed a prospective study to investigate whether there is indeed an association between NEC and specific pathogens. Between April 1993 and March 1997, stools of neonates of P < 0.05] and a higher proportion of infants who had only been formula fed (63 vs. 32%, P < 0.05) in the cases. Within the last week prior to NEC, potentially pathogenic bacteria were identified in stools of all cases and 79% of controls (P < 0.05). However, there was no significant difference in the occurrence of specific pathogens or groups of pathogens in cases compared with controls. Conclusion Although gut colonisation with potential pathogens appeared to be a prerequisite for the development of NEC, there were no specific bacteria associated with this disease if data from infants with NEC were compared with those from time- and gestational age-matched controls.
- 1 January 1999
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 158 (1) , 67-70
Necrotising enterocolitis: is there a relationship to specific pathogens?
Outbreaks of necrotising enterocolitis (NEC) have often been related to specific pathogens such as Enterobacteriaceae. This relationship, however, remains uncertain because of the retrospective nature of the studies addressing this issue. We performed a prospective study to investigate whether there is indeed an association between NEC and specific pathogens. Between April 1993 and March 1997, stools of neonates of P < 0.05] and a higher proportion of infants who had only been formula fed (63 vs. 32%, P < 0.05) in the cases. Within the last week prior to NEC, potentially pathogenic bacteria were identified in stools of all cases and 79% of controls (P < 0.05). However, there was no significant difference in the occurrence of specific pathogens or groups of pathogens in cases compared with controls. Conclusion Although gut colonisation with potential pathogens appeared to be a prerequisite for the development of NEC, there were no specific bacteria associated with this disease if data from infants with NEC were compared with those from time- and gestational age-matched controls.
- 1 March 1995
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 154 (4) , 326-329
Sudden infant death and maternal cigarette smoking: results from the Lower Saxony Perinatal Working Group
- 1 March 1995
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 154 (4) , 326-329
Sudden infant death and maternal cigarette smoking: results from the Lower Saxony Perinatal Working Group
- 1 November 1992
- Published by Springer Nature in Pediatric Research
- Vol. 32 (5) , 614
THE RELATIONSHIP BETWEEN EPISODES OF BRADYCARDIA, APNOEA AND HYPOXAEMIA IN PRETERM INFANTS
- 1 November 1992
- Published by Springer Nature in Pediatric Research
- Vol. 32 (5) , 614
THE RELATIONSHIP BETWEEN EPISODES OF BRADYCARDIA, APNOEA AND HYPOXAEMIA IN PRETERM INFANTS