Trevor E. Swartz
Trevor E. Swartz has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Bruce Kabakoff
Early Stage Pharmaceutical Development Department
2 shared publicationsIlya Chorny
Simprota Corp., San Francisco, CA 94158; and
2 shared publicationsThomas W. Patapoff
Early Stage Pharmaceutical Development Department
2 shared publicationsBoyan Zhang
Protein Analytical Chemistry, and
1 shared publication- Bruce Kabakoff
Genentech/Roche
1 shared publication - C. J. Morgan
Pharma Technical Regulatory, Genentech Inc., South San Francisco, CA; and
1 shared publication
Latest Publications
- 18 April 2016
- Published by Parenteral Drug Association, Inc. in PDA Journal of Pharmaceutical Science and Technology
- Vol. 70 (4) , 361-381
A Spectral Method for Color Quantitation of a Protein Drug Solution
In the biotechnology industry, a visual method is most commonly utilized for color characterization of liquid drug protein solutions. The color testing method is used for both batch release and on stability testing for quality control. Using that method, an analyst visually determines the color of the sample by choosing the closest matching European Pharmacopeia (Ph. Eur.) reference color solution. The requirement to judge the best match makes it a subjective method. Furthermore, the visual method does not capture data on hue or chroma that would allow for improved product characterization and the ability to detect subtle differences between samples. To overcome these challenges, we describe a quantitative method for color determination that greatly reduces the variability in measuring color and allows for a more precise understanding of color differences. Following color industry standards established by International Commission on Illumination, this method converts a protein solution's visible absorption spectra to L*a*b* color space. Color matching is achieved within the L*a*b* color space, a practice that is already widely used in other industries. The work performed here is to facilitate the adoption and transition for the traditional visual assessment method to a quantitative spectral method. We describe here the algorithm used such that the quantitative spectral method correlates with the currently used visual method. In addition, we provide the L*a*b* values for the Ph. Eur. reference color solutions required for the quantitative method. We have determined these L*a*b* values by gravimetrically preparing and measuring multiple lots of the reference color solutions. We demonstrate that the visual assessment and the quantitative spectral method are comparable using both low and high concentration antibody solutions and solutions with varying turbidity.
- 18 April 2016
- Published by Parenteral Drug Association, Inc. in PDA Journal of Pharmaceutical Science and Technology
- Vol. 70 (4) , 361-381
A Spectral Method for Color Quantitation of a Protein Drug Solution
In the biotechnology industry, a visual method is most commonly utilized for color characterization of liquid drug protein solutions. The color testing method is used for both batch release and on stability testing for quality control. Using that method, an analyst visually determines the color of the sample by choosing the closest matching European Pharmacopeia (Ph. Eur.) reference color solution. The requirement to judge the best match makes it a subjective method. Furthermore, the visual method does not capture data on hue or chroma that would allow for improved product characterization and the ability to detect subtle differences between samples. To overcome these challenges, we describe a quantitative method for color determination that greatly reduces the variability in measuring color and allows for a more precise understanding of color differences. Following color industry standards established by International Commission on Illumination, this method converts a protein solution's visible absorption spectra to L*a*b* color space. Color matching is achieved within the L*a*b* color space, a practice that is already widely used in other industries. The work performed here is to facilitate the adoption and transition for the traditional visual assessment method to a quantitative spectral method. We describe here the algorithm used such that the quantitative spectral method correlates with the currently used visual method. In addition, we provide the L*a*b* values for the Ph. Eur. reference color solutions required for the quantitative method. We have determined these L*a*b* values by gravimetrically preparing and measuring multiple lots of the reference color solutions. We demonstrate that the visual assessment and the quantitative spectral method are comparable using both low and high concentration antibody solutions and solutions with varying turbidity.
- Top Cited Papers
- 15 December 2014
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 111 (52) , 18601-18606
In silico selection of therapeutic antibodies for development: Viscosity, clearance, and chemical stability
Significance: mAbs are increasingly being used for treatment of chronic diseases wherein the subcutaneous delivery route is preferred to enable self-administration and at-home use. To deliver high doses (several hundred milligrams) through a small volume (∼1 mL) into the subcutaneous space, mAb solutions need to have low viscosity. Concomitantly, acceptable chemical stability is required for adequate shelf life, and normal in vivo clearance is needed for less frequent dosing. We propose in silico tools that provide rapid assessment of atypical behavior of mAbs (high viscosity, chemical degradation, and fast plasma clearance), which are simply predicted from sequence and/or structure-derived parameters. Such analysis will greatly improve the probability of success to move mAb-based therapeutics efficiently into clinical development and ultimately benefit patients.
- 15 December 2014
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 111 (52) , 18601-18606
Top Cited PapersIn silico selection of therapeutic antibodies for development: Viscosity, clearance, and chemical stability
Significance: mAbs are increasingly being used for treatment of chronic diseases wherein the subcutaneous delivery route is preferred to enable self-administration and at-home use. To deliver high doses (several hundred milligrams) through a small volume (∼1 mL) into the subcutaneous space, mAb solutions need to have low viscosity. Concomitantly, acceptable chemical stability is required for adequate shelf life, and normal in vivo clearance is needed for less frequent dosing. We propose in silico tools that provide rapid assessment of atypical behavior of mAbs (high viscosity, chemical degradation, and fast plasma clearance), which are simply predicted from sequence and/or structure-derived parameters. Such analysis will greatly improve the probability of success to move mAb-based therapeutics efficiently into clinical development and ultimately benefit patients.
- Open Access
- 1 March 2013
- Published by Taylor & Francis in mAbs
- Vol. 5 (2) , 306-322
Probing antibody internal dynamics with fluorescence anisotropy and molecular dynamics simulations
The solution dynamics of antibodies are critical to antibody function. We explore the internal solution dynamics of antibody molecules through the combination of time-resolved fluorescence anisotropy experiments on IgG1 with more than two microseconds of all-atom molecular dynamics (MD) simulations in explicit water, an order of magnitude more than in previous simulations. We analyze the correlated motions with a mutual information entropy quantity, and examine state transition rates in a Markov-state model, to give coarse-grained descriptors of the motions. Our MD simulations show that while there are many strongly correlated motions, antibodies are highly flexible, with Fab and Fc domains constantly forming and breaking contacts, both polar and non-polar. We find that salt bridges break and reform, and not always with the same partners. While the MD simulations in explicit water give the right time scales for the motions, the simulated motions are about 3-fold faster than the experiments. Overall, the p...
- 1 March 2013
- Published by Taylor & Francis in mAbs
- Vol. 5 (2) , 306-322
Open AccessProbing antibody internal dynamics with fluorescence anisotropy and molecular dynamics simulations
The solution dynamics of antibodies are critical to antibody function. We explore the internal solution dynamics of antibody molecules through the combination of time-resolved fluorescence anisotropy experiments on IgG1 with more than two microseconds of all-atom molecular dynamics (MD) simulations in explicit water, an order of magnitude more than in previous simulations. We analyze the correlated motions with a mutual information entropy quantity, and examine state transition rates in a Markov-state model, to give coarse-grained descriptors of the motions. Our MD simulations show that while there are many strongly correlated motions, antibodies are highly flexible, with Fab and Fc domains constantly forming and breaking contacts, both polar and non-polar. We find that salt bridges break and reform, and not always with the same partners. While the MD simulations in explicit water give the right time scales for the motions, the simulated motions are about 3-fold faster than the experiments. Overall, the p...