William E. Asher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
William E. Asher has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Andrew T. Jessup
Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
2 shared publicationsChristine Richardson
Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
1 shared publication- Mark R. Loewen
Department of Civil and Environmental Engineering, University of Alberta, Edmonton, AB, T6G 1H9, Canada
1 shared publication Mohamed A. Atmane
Applied Physics Laboratory University of Washington Seattle Washington USA
1 shared publicationMuhammad H. K. Siddiqui
Department of Civil and Environmental Engineering, University of Alberta, Edmonton, Alberta, Canada
1 shared publicationTrina M. Litchendorf
Applied Physics Laboratory, University of Washington, Seattle, USA
1 shared publication
Latest Publications
- Open Access
- 20 March 2013
- Published by Wiley
- p. 11-16
Turbulence Generated by Microscale Breaking Waves and its Influence on Air-Water Gas Transfer
- 20 March 2013
- Published by Wiley
- p. 11-16
Open AccessTurbulence Generated by Microscale Breaking Waves and its Influence on Air-Water Gas Transfer
- Open Access
- 9 January 2009
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 9 (1) , 131-139
The effects of experimental uncertainty in parameterizing air-sea gas exchange using tracer experiment data
It is not practical to measure air-sea gas fluxes in the open ocean for all conditions and areas of interest. Therefore, in many cases fluxes are estimated from measurements of air-phase and water-phase gas concentrations, a measured environmental forcing function such as wind speed, and a parameterization of the air-sea transfer velocity in terms of the environmental forcing function. One problem with this approach is that when direct measurements of the transfer velocity are plotted versus the most commonly used forcing function, wind speed, there is considerable scatter, leading to a relatively large uncertainty in the flux. Because it is known that multiple processes can affect gas transfer, it is commonly assumed that this scatter is caused by single-forcing function parameterizations being incomplete in a physical sense. However, scatter in the experimental data can also result from experimental uncertainty (i.e., measurement error). Here, results from field and laboratory results are used to estimate how experimental uncertainty contributes to the observed scatter in the measured fluxes and transfer velocities as a function of environmental forcing. The results show that experimental uncertainty could explain half of the observed scatter in field and laboratory measurements of air-sea gas transfer velocity.
- 9 January 2009
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 9 (1) , 131-139
Open AccessThe effects of experimental uncertainty in parameterizing air-sea gas exchange using tracer experiment data
It is not practical to measure air-sea gas fluxes in the open ocean for all conditions and areas of interest. Therefore, in many cases fluxes are estimated from measurements of air-phase and water-phase gas concentrations, a measured environmental forcing function such as wind speed, and a parameterization of the air-sea transfer velocity in terms of the environmental forcing function. One problem with this approach is that when direct measurements of the transfer velocity are plotted versus the most commonly used forcing function, wind speed, there is considerable scatter, leading to a relatively large uncertainty in the flux. Because it is known that multiple processes can affect gas transfer, it is commonly assumed that this scatter is caused by single-forcing function parameterizations being incomplete in a physical sense. However, scatter in the experimental data can also result from experimental uncertainty (i.e., measurement error). Here, results from field and laboratory results are used to estimate how experimental uncertainty contributes to the observed scatter in the measured fluxes and transfer velocities as a function of environmental forcing. The results show that experimental uncertainty could explain half of the observed scatter in field and laboratory measurements of air-sea gas transfer velocity.
- 28 August 2008
- Published by Springer Nature in Experiments in Fluids
- Vol. 46 (2) , 243-253
Visualizing near-surface concentration fluctuations using laser-induced fluorescence
- 28 August 2008
- Published by Springer Nature in Experiments in Fluids
- Vol. 46 (2) , 243-253
Visualizing near-surface concentration fluctuations using laser-induced fluorescence
- 13 August 2004
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Oceans
- Vol. 109 (C8)
Oceanic application of the active controlled flux technique for measuring air‐sea transfer velocities of heat and gases
Detailed understanding of the hydrodynamic mechanisms controlling the air‐sea exchange of heat and gas requires a method for rapid measurement of the associated transfer velocities. The active controlled flux technique (ACFT), where the temperature decay of a small patch of water heated by an infrared laser is tracked using an infrared imager, has been proposed as a method for making these fast noninvasive measurements of the heat and gas transfer velocities. Here, we report on ACFT measurements of the transfer velocity of heat, kH, made in the ocean during the Fluxes, Air‐sea Interactions and Remote Sensing (FAIRS) experiment (September/October, 2000) and GasEx‐01 (January/February, 2001). The results for kH from both FAIRS and GasEx‐01 compare favorably when plotted versus wind speed. However, when scaled to a Schmidt number of 660, the measured kH values were found to be a factor of two larger than gas transfer velocities measured during GasEx‐01. The ACFT‐derived kH values were combined with direct measurements of the bulk‐skin oceanic temperature difference to calculate net air‐sea heat fluxes during both experiments. Comparison of these values with heat fluxes determined by direct measurements of the latent, sensible, and radiative heat fluxes showed that the ACFT measurements are a factor of seven larger than the direct measurements. One possible theory explaining both the overprediction of the gas transfer velocities and the scale factor between the measured and calculated net heat fluxes is that air‐sea exchange is best described by surface penetration rather than surface renewal.
- 13 August 2004
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Oceans
- Vol. 109 (C8)
Oceanic application of the active controlled flux technique for measuring air‐sea transfer velocities of heat and gases
Detailed understanding of the hydrodynamic mechanisms controlling the air‐sea exchange of heat and gas requires a method for rapid measurement of the associated transfer velocities. The active controlled flux technique (ACFT), where the temperature decay of a small patch of water heated by an infrared laser is tracked using an infrared imager, has been proposed as a method for making these fast noninvasive measurements of the heat and gas transfer velocities. Here, we report on ACFT measurements of the transfer velocity of heat, kH, made in the ocean during the Fluxes, Air‐sea Interactions and Remote Sensing (FAIRS) experiment (September/October, 2000) and GasEx‐01 (January/February, 2001). The results for kH from both FAIRS and GasEx‐01 compare favorably when plotted versus wind speed. However, when scaled to a Schmidt number of 660, the measured kH values were found to be a factor of two larger than gas transfer velocities measured during GasEx‐01. The ACFT‐derived kH values were combined with direct measurements of the bulk‐skin oceanic temperature difference to calculate net air‐sea heat fluxes during both experiments. Comparison of these values with heat fluxes determined by direct measurements of the latent, sensible, and radiative heat fluxes showed that the ACFT measurements are a factor of seven larger than the direct measurements. One possible theory explaining both the overprediction of the gas transfer velocities and the scale factor between the measured and calculated net heat fluxes is that air‐sea exchange is best described by surface penetration rather than surface renewal.