Ch. Menenakos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ch. Menenakos has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
C. Braumann
Department of General, Visceral, Vascular and Thoracic Surgery, Charité – Universitaetsmedizin Berlin
1 shared publicationJ. Hartmann
Charité, Universitaetsmedizin Berlin
1 shared publicationM. Kilian
Charité, Universitaetsmedizin Berlin
1 shared publicationN. Guenther
Department of General, Visceral, Vascular and Thoracic Surgery, Charité – Universitaetsmedizin Berlin
1 shared publication- Nikolaos Tsilimparis
Department of Vascular Surgery, Ludwig-Maximillian University Hospital, Munich, Germany
1 shared publication
Latest Publications
- 7 August 2009
- Published by Springer Nature in Hernia
- Vol. 14 (3) , 309-312
Single-port access in laparoscopic bilateral inguinal hernia repair: first clinical report of a novel technique
To report the initial clinical case of single-port transabdominal preperitoneal (TAPP) bilateral inguinal hernia repair. One patient with symptomatic bilateral inguinal hernias underwent a single-port TAPP hernia repair using the Triport Single Port System (ASC, TriPort Laparoscopic Access Device, Wicklow, Ireland). The device was placed through a single supraumbilical incision. Hernia repair was performed with a typical TAPP technique with implantation of an Ultrapro® Mesh (Ethicon, Norderstedt, Germany). The procedure was technically successful without placement of additional trocars. Operative time was 120 min. No blood loss and no intraoperative complications were observed. The patient was discharged on the 2nd postoperative day and follow-up at 2 weeks demonstrated the patient to be without complaints with uncomplicated wound healing. Single-port TAPP bilateral inguinal hernia repair is technically feasible and safe.
- 7 August 2009
- Published by Springer Nature in Hernia
- Vol. 14 (3) , 309-312
Single-port access in laparoscopic bilateral inguinal hernia repair: first clinical report of a novel technique
To report the initial clinical case of single-port transabdominal preperitoneal (TAPP) bilateral inguinal hernia repair. One patient with symptomatic bilateral inguinal hernias underwent a single-port TAPP hernia repair using the Triport Single Port System (ASC, TriPort Laparoscopic Access Device, Wicklow, Ireland). The device was placed through a single supraumbilical incision. Hernia repair was performed with a typical TAPP technique with implantation of an Ultrapro® Mesh (Ethicon, Norderstedt, Germany). The procedure was technically successful without placement of additional trocars. Operative time was 120 min. No blood loss and no intraoperative complications were observed. The patient was discharged on the 2nd postoperative day and follow-up at 2 weeks demonstrated the patient to be without complaints with uncomplicated wound healing. Single-port TAPP bilateral inguinal hernia repair is technically feasible and safe.
- 1 January 2009
- Published by Taylor & Francis in Acta Chirurgica Belgica
- Vol. 109 (3) , 411-413
Strangulated Appendix within a Trocar Site Incisional Hernia Following Laparoscopic Low Anterior Rectal Resection. A Case Report
Appendix strangulation caused by an incisional trocar site hernia following laparoscopy is an extremely rare entity. A 63-year-old man was admitted to our department with continuous abdominal pain and irreducible minimal swelling in the right abdomen. His surgical history was significant for rectal cancer one year previously. The patient had undergone a laparoscopic low anterior rectal resection with construction of a protective temporary end ileostomy (pT1, pN0, G2, M0). The ileostomy was reversed 3 months after initial surgery. An incarcerated herniation was diagnosed. Subsequent surgery surprisingly revealed that the right lower trocar point incisional hernia contained a strangulated appendix. Routine appendectomy was performed and the hernias were repaired using a typical sublay technique.
- 1 January 2009
- Published by Taylor & Francis in Acta Chirurgica Belgica
- Vol. 109 (3) , 411-413
Strangulated Appendix within a Trocar Site Incisional Hernia Following Laparoscopic Low Anterior Rectal Resection. A Case Report
Appendix strangulation caused by an incisional trocar site hernia following laparoscopy is an extremely rare entity. A 63-year-old man was admitted to our department with continuous abdominal pain and irreducible minimal swelling in the right abdomen. His surgical history was significant for rectal cancer one year previously. The patient had undergone a laparoscopic low anterior rectal resection with construction of a protective temporary end ileostomy (pT1, pN0, G2, M0). The ileostomy was reversed 3 months after initial surgery. An incarcerated herniation was diagnosed. Subsequent surgery surprisingly revealed that the right lower trocar point incisional hernia contained a strangulated appendix. Routine appendectomy was performed and the hernias were repaired using a typical sublay technique.